-- VIEWLIGHT-MIB
|
|
--
|
|
-- VIEWLIGHT-MIB created 12/20/2011 as Version 1.06 for
|
|
-- the digital cinema projector by NEC Display Solutions, Ltd.
|
|
|
|
VIEWLIGHT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
|
|
TimeTicks, Counter32, enterprises
|
|
FROM SNMPv2-SMI
|
|
DisplayString
|
|
FROM SNMPv2-TC;
|
|
|
|
|
|
|
|
nec OBJECT IDENTIFIER ::= { enterprises 119 }
|
|
|
|
necProduct OBJECT IDENTIFIER ::= { nec 1 }
|
|
|
|
nec-mib OBJECT IDENTIFIER ::= { nec 2 }
|
|
necProductDepend OBJECT IDENTIFIER ::= { nec-mib 3 }
|
|
|
|
-- necExperimental OBJECT IDENTIFIER ::= { nec 3 }
|
|
-- necProductEx OBJECT IDENTIFIER ::= { necExperimental 2 }
|
|
|
|
--
|
|
-- ViewLight Private MIB
|
|
--
|
|
viewlight OBJECT IDENTIFIER ::= { necProduct 123 }
|
|
viewlight-mib OBJECT IDENTIFIER ::= { necProductDepend 123 }
|
|
-- viewlight-ex OBJECT IDENTIFIER ::= { necProductEx 123 }
|
|
|
|
vTraps OBJECT IDENTIFIER ::= { viewlight-mib 0 }
|
|
vSystem OBJECT IDENTIFIER ::= { viewlight-mib 1 }
|
|
vLamp OBJECT IDENTIFIER ::= { viewlight-mib 2 }
|
|
vInput OBJECT IDENTIFIER ::= { viewlight-mib 3 }
|
|
vOutput OBJECT IDENTIFIER ::= { viewlight-mib 4 }
|
|
vSetting OBJECT IDENTIFIER ::= { viewlight-mib 5 }
|
|
|
|
|
|
--
|
|
-- * vSystem **********************************************
|
|
--
|
|
--<< vSystem 1 >>--
|
|
vSystemName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the name that is set in the projector."
|
|
::= { vSystem 1 }
|
|
|
|
|
|
--<< vSystem 2 >>--
|
|
vVersion OBJECT IDENTIFIER ::= { vSystem 2 }
|
|
|
|
vVerBIOS OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the BIOS version number of System for
|
|
the projector."
|
|
::= { vVersion 1 }
|
|
|
|
vVerFirm OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the firmware version number of System
|
|
for the projector."
|
|
::= { vVersion 2 }
|
|
|
|
vVerData OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the data version number of System for
|
|
the projector."
|
|
::= { vVersion 3 }
|
|
|
|
--<< vSystem 3 >>--
|
|
vStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
powerOff(1),
|
|
powerOn(2),
|
|
cooling(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the power supply status of the projector."
|
|
::= { vSystem 3 }
|
|
|
|
--<< vSystem 4 >>--
|
|
vAlert OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vSystem 4 }
|
|
|
|
--<< vSystem 5 >>--
|
|
vSystemTime OBJECT IDENTIFIER ::= { vSystem 5 }
|
|
|
|
vSystemTmProjector OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the total usage time of the projector.
|
|
(System Usage)"
|
|
::= { vSystemTime 1 }
|
|
|
|
vSystemTmFilter OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vSystemTime 2 }
|
|
|
|
vSystemTmFilterLamp OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the total usage time of the lamp filter."
|
|
::= { vSystemTime 3 }
|
|
|
|
vSystemTmFilterBody OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the total usage time of the body filter."
|
|
::= { vSystemTime 4 }
|
|
|
|
vSystemTmFanACOn OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the total usage time of the fan during ac on.
|
|
(AC On Fan Usage)"
|
|
::= { vSystemTime 5 }
|
|
|
|
vSystemTmFanPowerOn OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the total usage time of the fan during power on.
|
|
(Power On Fan Usage)"
|
|
::= { vSystemTime 6 }
|
|
|
|
vSystemTmFanLamp OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the total usage time of the fan during lamp on.
|
|
(Lamp Fan Usage)"
|
|
::= { vSystemTime 7 }
|
|
|
|
vSystemDouserCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The counts of douser(open/close)."
|
|
::= { vSystemTime 8 }
|
|
|
|
vSystemTmFilterUsage OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the total usage time of the filter."
|
|
::= { vSystemTime 9 }
|
|
|
|
vSystemTmFanUsage OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the total usage time of the fan during power on."
|
|
::= { vSystemTime 10 }
|
|
|
|
--<< vSystem 6 >>--
|
|
vSystemDouser OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open(1),
|
|
close(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The Douser mode setting."
|
|
::= { vSystem 6 }
|
|
|
|
--<< vSystem 7 >>--
|
|
vSystemTemperature OBJECT IDENTIFIER ::= { vSystem 7 }
|
|
|
|
vSystemCinemaTemp OBJECT-TYPE
|
|
SYNTAX INTEGER(-1270..1270)
|
|
UNITS "x0.1'C"
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Ambient temperature on the Cinema board in degrees C."
|
|
::= { vSystemTemperature 1 }
|
|
|
|
vSystemChestTemp OBJECT-TYPE
|
|
SYNTAX INTEGER(-1270..1270)
|
|
UNITS "x0.1'C"
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Temperature on the Cinema board chest in degrees C."
|
|
::= { vSystemTemperature 2 }
|
|
|
|
vSystemDMDTemp OBJECT-TYPE
|
|
SYNTAX INTEGER(-1270..1270)
|
|
UNITS "x0.1'C"
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Temperature on the DMD in degrees C."
|
|
::= { vSystemTemperature 3 }
|
|
|
|
vSystemOutsideAirTemp OBJECT-TYPE
|
|
SYNTAX INTEGER(-1270..1270)
|
|
UNITS "x0.1'C"
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Temperature in the outside air in degrees C."
|
|
::= { vSystemTemperature 4 }
|
|
|
|
vSystemInsideAirTemp OBJECT-TYPE
|
|
SYNTAX INTEGER(-1270..1270)
|
|
UNITS "x0.1'C"
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Temperature in the inside air in degrees C."
|
|
::= { vSystemTemperature 5 }
|
|
|
|
vSystemRearsideAirTemp OBJECT-TYPE
|
|
SYNTAX INTEGER(-1270..1270)
|
|
UNITS "x0.1'C"
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Temperature in the rearside air in degrees C."
|
|
::= { vSystemTemperature 6 }
|
|
|
|
vSystemCinemaMAX6656Temp OBJECT-TYPE
|
|
SYNTAX INTEGER(0..1270)
|
|
UNITS "x0.1'C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Temperature of MAX6656 on the ICP board in degrees C."
|
|
::= { vSystemTemperature 7 }
|
|
|
|
vSystemCinemaICPFPGATemp OBJECT-TYPE
|
|
SYNTAX INTEGER(0..1270)
|
|
UNITS "x0.1'C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Temperature of ICP FPGA on the ICP board in degrees C."
|
|
::= { vSystemTemperature 8 }
|
|
|
|
vSystemCinemaFMTFPGATemp OBJECT-TYPE
|
|
SYNTAX INTEGER(0..1270)
|
|
UNITS "x0.1'C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Temperature of FMT FPGA on the ICP board in degrees C."
|
|
::= { vSystemTemperature 9 }
|
|
|
|
vSystemS2OutsideAirTemp OBJECT-TYPE
|
|
SYNTAX INTEGER(-1270..1270)
|
|
UNITS "x0.1'C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Temperature in the outside air in degrees C."
|
|
::= { vSystemTemperature 10 }
|
|
|
|
vSystemS2LPSUIntakeTemp OBJECT-TYPE
|
|
SYNTAX INTEGER(-1270..1270)
|
|
UNITS "x0.1'C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Temperature in the LPSU Intake in degrees C."
|
|
::= { vSystemTemperature 11 }
|
|
|
|
vSystemS2ExhaustTemp OBJECT-TYPE
|
|
SYNTAX INTEGER(-1270..1270)
|
|
UNITS "x0.1'C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Temperature in the Exhaust in degrees C."
|
|
::= { vSystemTemperature 12 }
|
|
|
|
vSystemS2DMDBTemp OBJECT-TYPE
|
|
SYNTAX INTEGER(-1270..1270)
|
|
UNITS "x0.1'C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Temperature on the DMD-B in degrees C."
|
|
::= { vSystemTemperature 13 }
|
|
|
|
vSystemYsTempDMD OBJECT-TYPE
|
|
SYNTAX INTEGER(-200..1000)
|
|
UNITS "x0.1'C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Temperature on the DMD in degrees C."
|
|
::= { vSystemTemperature 14 }
|
|
|
|
vSystemYsTempInlet OBJECT-TYPE
|
|
SYNTAX INTEGER(-200..1000)
|
|
UNITS "x0.1'C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Temperature on the Inlet in degrees C."
|
|
::= { vSystemTemperature 15 }
|
|
|
|
vSystemYsTempBallast1 OBJECT-TYPE
|
|
SYNTAX INTEGER(-200..1000)
|
|
UNITS "x0.1'C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Temperature on the Ballast1 in degrees C."
|
|
::= { vSystemTemperature 16 }
|
|
|
|
vSystemYsTempBallast2 OBJECT-TYPE
|
|
SYNTAX INTEGER(-200..1000)
|
|
UNITS "x0.1'C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Temperature on the Ballast2 in degrees C."
|
|
::= { vSystemTemperature 17 }
|
|
|
|
--<< vSystem 8 >>--
|
|
vSystemError OBJECT IDENTIFIER ::= { vSystem 8 }
|
|
|
|
vSystemErrorCounts OBJECT-TYPE
|
|
SYNTAX INTEGER(0..128)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of current occurring errors."
|
|
::= { vSystemError 1 }
|
|
|
|
vSystemErrorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SystemErrorInfo
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This is a hierarchical tree for the error
|
|
information related to the projector system.
|
|
This object does not have a value."
|
|
::= { vSystemError 2 }
|
|
|
|
SystemErrorInfo ::= SEQUENCE {
|
|
vSystemErrorIndex INTEGER,
|
|
vSystemErrorInformation DisplayString (SIZE(0..63))
|
|
}
|
|
|
|
vSystemErrorEntry OBJECT-TYPE
|
|
SYNTAX SystemErrorInfo
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This is a hierarchical tree for the error
|
|
information related to the projector system.
|
|
This object does not have a value."
|
|
INDEX { vSystemErrorIndex }
|
|
::= { vSystemErrorTable 1 }
|
|
|
|
vSystemErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "These are the characteristic numbers that are
|
|
assigned to the various errors.
|
|
The x within the OID can be any integer value
|
|
from 1 to vSystemErrorCounts."
|
|
::= { vSystemErrorEntry 1 }
|
|
|
|
vSystemErrorInformation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the error information.
|
|
The x within the OID can be any integer value
|
|
from 1 to vSystemErrorCounts.
|
|
|
|
Format : `YYYY/MM/DD HH:MM:SS(n) sss' + NULL
|
|
YYYY : Year
|
|
MM : Month
|
|
DD : Date
|
|
HH : Hour
|
|
MM : Minute
|
|
SS : Second
|
|
n : number of error
|
|
sss : error message"
|
|
::= { vSystemErrorEntry 2 }
|
|
|
|
vSystemErrorCriticalCounts OBJECT-TYPE
|
|
SYNTAX INTEGER(0..128)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of current occurring errors.(Critical Error)"
|
|
::= { vSystemError 3 }
|
|
|
|
vSystemErrorNonCriticalCounts OBJECT-TYPE
|
|
SYNTAX INTEGER(0..128)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of current occurring errors.(Non-Critical Error)"
|
|
::= { vSystemError 4 }
|
|
|
|
vSystemErrorCriticalNewCounts OBJECT-TYPE
|
|
SYNTAX INTEGER(0..128)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of new occurring errors since last trap issued.
|
|
(Critical Error)"
|
|
::= { vSystemError 5 }
|
|
|
|
vSystemErrorCriticalTrapNewErrorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CriticalTrapNewError
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This is a hierarchical tree for the new occurred error table.
|
|
( Critical-Error )
|
|
This object does not have a value."
|
|
::= { vSystemError 6 }
|
|
|
|
CriticalTrapNewError ::= SEQUENCE {
|
|
vSystemErrorCriticalTrapNewErrorIndex INTEGER,
|
|
vSystemErrorCriticalTrapNewErrorNumber INTEGER
|
|
}
|
|
|
|
vSystemErrorCriticalTrapNewError OBJECT-TYPE
|
|
SYNTAX CriticalTrapNewError
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This is a hierarchical tree for the new occurred error table.
|
|
( Critical-Error )
|
|
This object does not have a value."
|
|
INDEX { vSystemErrorCriticalTrapNewErrorIndex }
|
|
::= { vSystemErrorCriticalTrapNewErrorTable 1 }
|
|
|
|
vSystemErrorCriticalTrapNewErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "These are the characteristic numbers that are
|
|
assigned to the various errors.
|
|
The x within the OID can be any integer value
|
|
from 1 to vSystemErrorCriticalNewCounts."
|
|
::= { vSystemErrorCriticalTrapNewError 1 }
|
|
|
|
vSystemErrorCriticalTrapNewErrorNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the new occurred error number.
|
|
( Critical-Error )"
|
|
::= { vSystemErrorCriticalTrapNewError 2 }
|
|
|
|
|
|
vSystemErrorNonCriticalNewCounts OBJECT-TYPE
|
|
SYNTAX INTEGER(0..128)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of new occurring errors since last trap issued.
|
|
(Non-Critical Error)"
|
|
::= { vSystemError 7 }
|
|
|
|
vSystemErrorNonCriticalTrapNewErrorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NonCriticalTrapNewError
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This is a hierarchical tree for the new occurred error table.
|
|
( Non-Critical-Error )
|
|
This object does not have a value."
|
|
::= { vSystemError 8 }
|
|
|
|
NonCriticalTrapNewError ::= SEQUENCE {
|
|
vSystemErrorNonCriticalTrapNewErrorIndex INTEGER,
|
|
vSystemErrorNonCriticalTrapNewErrorNumber INTEGER
|
|
}
|
|
|
|
vSystemErrorNonCriticalTrapNewError OBJECT-TYPE
|
|
SYNTAX NonCriticalTrapNewError
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This is a hierarchical tree for the new occurred error table.
|
|
( Non-Critical-Error )
|
|
This object does not have a value."
|
|
INDEX { vSystemErrorNonCriticalTrapNewErrorIndex }
|
|
::= { vSystemErrorNonCriticalTrapNewErrorTable 1 }
|
|
|
|
vSystemErrorNonCriticalTrapNewErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "These are the characteristic numbers that are
|
|
assigned to the various errors.
|
|
The x within the OID can be any integer value
|
|
from 1 to vSystemErrorNonCriticalNewCounts."
|
|
::= { vSystemErrorNonCriticalTrapNewError 1 }
|
|
|
|
vSystemErrorNonCriticalTrapNewErrorNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the new occurred error number.
|
|
( Non-Critical-Error )"
|
|
::= { vSystemErrorNonCriticalTrapNewError 2 }
|
|
|
|
vSystemErrorInDirectNumber OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF InDirectNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This is a hierarchical tree for the system error in Direct number.
|
|
This object does not have a value."
|
|
::= { vSystemError 9 }
|
|
|
|
InDirectNumber ::= SEQUENCE {
|
|
vErrLampDoorOpen INTEGER,
|
|
vErrLampOverTemp INTEGER,
|
|
vErrGPSU12VFail INTEGER,
|
|
vErrLampUnlit INTEGER,
|
|
vErrHouseOverTime INTEGER,
|
|
vErrLPSUOverTemp INTEGER,
|
|
vErrE2PROMRFail INTEGER,
|
|
vErrInterlockFail INTEGER,
|
|
vErrE2PROMWFail INTEGER,
|
|
vErrPumpStop INTEGER,
|
|
vErrDLPAckFail INTEGER,
|
|
vErrLensFail INTEGER,
|
|
vErrBulbOverTime INTEGER,
|
|
vErrLPSUFail INTEGER,
|
|
vErrOutRange INTEGER,
|
|
vErrDownLampPower INTEGER,
|
|
vErrMMSCommFail INTEGER,
|
|
vErrMMSFanStop INTEGER,
|
|
vErrMMSFail INTEGER,
|
|
vErrMMReset INTEGER,
|
|
vErrDLPCommRFail INTEGER,
|
|
vErrDLPCommEFail INTEGER,
|
|
vErrSensorFailOutsideAir INTEGER,
|
|
vErrSensorFailLPSUIntake INTEGER,
|
|
vErrSensorFailExhaust INTEGER,
|
|
vErrSensorFailDMDB INTEGER,
|
|
vErrFan0Stop INTEGER,
|
|
vErrFan1Stop INTEGER,
|
|
vErrFan2Stop INTEGER,
|
|
vErrFan3Stop INTEGER,
|
|
vErrFan4Stop INTEGER,
|
|
vErrFan5Stop INTEGER,
|
|
vErrFan6Stop INTEGER,
|
|
vErrFan7Stop INTEGER,
|
|
vErrFan8Stop INTEGER,
|
|
vErrFan9Stop INTEGER,
|
|
vErrGPSUFanStop INTEGER,
|
|
vErrLampFan0Stop INTEGER,
|
|
vErrLampFan1Stop INTEGER,
|
|
vErrICPFanStop INTEGER,
|
|
vErrGPIMACRO INTEGER,
|
|
vErrGPIControl INTEGER,
|
|
vErrOverTempOutsideAir INTEGER,
|
|
vErrOverTempPrecaution INTEGER,
|
|
vErrOverTempExhaust INTEGER,
|
|
vErrOverTempDMDB INTEGER,
|
|
vErrBulbEntry INTEGER,
|
|
vErrTamperFail INTEGER,
|
|
vErrMarriageTamperFail INTEGER,
|
|
vErrCPUFail INTEGER,
|
|
vErrGPSU24VFail INTEGER,
|
|
vErrLogWriteFail INTEGER,
|
|
vErrUnknownLPSUModel INTEGER,
|
|
vErrLPSUFanStop INTEGER,
|
|
vErr12VOutsiderange INTEGER,
|
|
vErr24VOutsiderange INTEGER,
|
|
vErrFilterTimeOver INTEGER,
|
|
vErrBodyFilterTimeOver INTEGER,
|
|
vErrFanExchangeTime INTEGER,
|
|
vErrPowerOnFanExchangeTime INTEGER,
|
|
vErrLampFanExchangeTime INTEGER,
|
|
vErrRouterFail INTEGER,
|
|
vErrSensorFailOpt INTEGER,
|
|
vErrMACWriteFail INTEGER,
|
|
vErrIllegalMACAddress INTEGER,
|
|
vErrRouterSelfCheckFail INTEGER,
|
|
vErrRouterFirmwareUpdateFail INTEGER,
|
|
vErrSIBCommFail INTEGER,
|
|
vErrSIBError INTEGER,
|
|
vErrSIBFPGAReboot INTEGER,
|
|
vErrFan10Stop INTEGER,
|
|
vErrFan11Stop INTEGER,
|
|
vErrFan12Stop INTEGER,
|
|
vErrFan13Stop INTEGER,
|
|
vErrFan14Stop INTEGER,
|
|
vErrFan0StopPrecaution INTEGER,
|
|
vErrFan1StopPrecaution INTEGER,
|
|
vErrFan2StopPrecaution INTEGER,
|
|
vErrFan3StopPrecaution INTEGER,
|
|
vErrFan4StopPrecaution INTEGER,
|
|
vErrFan5StopPrecaution INTEGER,
|
|
vErrFan6StopPrecaution INTEGER,
|
|
vErrFan7StopPrecaution INTEGER,
|
|
vErrFan8StopPrecaution INTEGER,
|
|
vErrFan9StopPrecaution INTEGER,
|
|
vErrLampFan0StopPrecaution INTEGER,
|
|
vErrLampFan1StopPrecaution INTEGER,
|
|
vErrPumpStopPrecaution INTEGER,
|
|
vErrICPFanStopPrecaution INTEGER,
|
|
vErrFan10StopPrecaution INTEGER,
|
|
vErrFan11StopPrecaution INTEGER,
|
|
vErrFan12StopPrecaution INTEGER,
|
|
vErrFan13StopPrecaution INTEGER,
|
|
vErrFan14StopPrecaution INTEGER,
|
|
vErrSDTamperTerminate INTEGER,
|
|
vErrIMBSDTamperTerminate INTEGER,
|
|
vErrBulbWarrantyOver INTEGER,
|
|
vErrSystemError INTEGER,
|
|
vErrSelfTestError INTEGER,
|
|
vErrInstallReleasePackage INTEGER,
|
|
vErrLoadReleasePackage INTEGER,
|
|
vErrKeyError INTEGER,
|
|
vErrCertificateError INTEGER,
|
|
vErrICPNormalConfiguration INTEGER,
|
|
vErrICPBootConfiguration INTEGER,
|
|
vErrFMTNormalConfiguration INTEGER,
|
|
vErrFMTBootConfiguration INTEGER,
|
|
vErrFMTSatelliteConfiguration INTEGER,
|
|
vErr120VSupplyoutofrange INTEGER,
|
|
vErr180VSupplyoutofrange INTEGER,
|
|
vErr250VSupplyoutofrange INTEGER,
|
|
vErr330VRegulatoroutofrange INTEGER,
|
|
vErrICPFPGATemperatureoutofrange INTEGER,
|
|
vErrFMTFPGATemperatureoutofrange INTEGER,
|
|
vErrICPFlashUpdate INTEGER,
|
|
vErrFMTSequenceDataFileMismatch INTEGER,
|
|
vErrFMTDMDDataFileMismatch INTEGER,
|
|
vErrFMTFlashChecksumSequenceData INTEGER,
|
|
vErrFMTFlashChecksumDMDData INTEGER,
|
|
vErrSatelliteHardwareMismatch INTEGER,
|
|
vErrFMTFlashUpdate INTEGER,
|
|
vErrRedSatelliteReportsReset INTEGER,
|
|
vErrRedSatelliteSerialLink INTEGER,
|
|
vErrRedSatelliteFirmwareConfiguration INTEGER,
|
|
vErrRedDAD1000BiasUnderVoltage INTEGER,
|
|
vErrRedDAD1000ResetUnderVoltage INTEGER,
|
|
vErrRedDAD1000OffsetUnderVoltage INTEGER,
|
|
vErrRedDAD1000ThermalShutdown INTEGER,
|
|
vErrGreenSatelliteReportsReset INTEGER,
|
|
vErrGreenSatelliteSerialLink INTEGER,
|
|
vErrGreenSatelliteFirmwareConfiguration INTEGER,
|
|
vErrGreenDAD1000BiasUnderVoltage INTEGER,
|
|
vErrGreenDAD1000ResetUnderVoltage INTEGER,
|
|
vErrGreenDAD1000OffsetUnderVoltage INTEGER,
|
|
vErrGreenDAD1000ThermalShutdown INTEGER,
|
|
vErrBlueSatelliteReportsReset INTEGER,
|
|
vErrBlueSatelliteSerialLink INTEGER,
|
|
vErrBlueSatelliteFirmwareConfiguration INTEGER,
|
|
vErrBlueDAD1000BiasUnderVoltage INTEGER,
|
|
vErrBlueDAD1000ResetUnderVoltage INTEGER,
|
|
vErrBlueDAD1000OffsetUnderVoltage INTEGER,
|
|
vErrBlueDAD1000ThermalShutdown INTEGER,
|
|
vErrRTCError INTEGER,
|
|
vErrICPFrameMemoryTestResult INTEGER,
|
|
vErrICPDataPathSignatureTestResult INTEGER,
|
|
vErrEnigmaCommFail INTEGER,
|
|
vErrEnigmaSystemError INTEGER,
|
|
vErrEnigmaSelfTestError INTEGER,
|
|
vErrEnigmaInstallReleasePackage INTEGER,
|
|
vErrEnigmaLoadReleasePackage INTEGER,
|
|
vErrEnigmaTILoginListPackage INTEGER,
|
|
vErrEnigmaSecurityOfficerLoginListPackage INTEGER,
|
|
vErrEnigmaCertificateorKey INTEGER,
|
|
vErrEnigmaICPCommunicationsStatus INTEGER,
|
|
vErrEnigmaUserLoaderIntegrity INTEGER,
|
|
vErrEnigmaMainApplicationIntegrity INTEGER,
|
|
vErrEnigmaRNGHardwareIntegrity INTEGER,
|
|
vErrEnigmaDRNGAlgorithmIntegrity INTEGER,
|
|
vErrEnigmaRSAAlgorithmIntegrity INTEGER,
|
|
vErrEnigmaAESAlgorithmIntegrity INTEGER,
|
|
vErrEnigmaHMACAlgorithmIntegrity INTEGER,
|
|
vErrEnigmaSHAAlgorithmIntegrity INTEGER,
|
|
vErrEnigmaTLSIntegrity INTEGER,
|
|
vErrEnigmaFPGAConfigurationIntegrity INTEGER,
|
|
vErrEnigmaFPGACineLink2 INTEGER,
|
|
vErrEnigmaRTCError INTEGER,
|
|
vErrEnigmaFPGAConfiguration INTEGER,
|
|
vErrEnigmaFPGATemperatureoutofrange INTEGER,
|
|
vErrEnigmaRNGHardwareDuplicateOutput INTEGER,
|
|
vErrEnigmaDRNGAlgorithmDuplicateOutput INTEGER,
|
|
vErrEnigma120VSupplyoutofrange INTEGER,
|
|
vErrEnigma180VSupplyoutofrange INTEGER,
|
|
vErrEnigma250VSupplyoutofrange INTEGER,
|
|
vErrEnigma330VRegulatoroutofrange INTEGER,
|
|
vErrEnigmaSelfTestUserLoader INTEGER,
|
|
vErrEnigmaSelfTestMainApplication INTEGER,
|
|
vErrEnigmaSelfTestRNGHardware INTEGER,
|
|
vErrEnigmaSelfTestDRNGAlgorithm INTEGER,
|
|
vErrEnigmaSelfTestRSAAlgorithm INTEGER,
|
|
vErrEnigmaSelfTestAESAlgorithm INTEGER,
|
|
vErrEnigmaSelfTestHMACAlgorithm INTEGER,
|
|
vErrEnigmaSelfTestSHAAlgorithm INTEGER,
|
|
vErrEnigmaSelfTestTLSIntegrity INTEGER,
|
|
vErrEnigmaSelfTestFPGAConfiguration INTEGER,
|
|
vErrEnigmaSelfTestFPGACineLink2 INTEGER,
|
|
vErrEnigmaSecurityTamper INTEGER,
|
|
vErrEnigmaTopSideSecurityEnclosureOpen INTEGER,
|
|
vErrEnigmaBottomSideSecurityEnclosureOpen INTEGER,
|
|
vErrEnigmaSecurityBatteryEvent INTEGER,
|
|
vErrEnigmaSoftwareCommandedZeroization INTEGER,
|
|
vErrEnigmaSecurityEnclosureNotArmed INTEGER,
|
|
vErrEnigmaPhysicalMarriageTamper INTEGER,
|
|
vErrEnigmaLogicalMarriageTamper INTEGER,
|
|
vErrEnigmaMarriageNOTActive INTEGER,
|
|
vErrEnigmaServiceDoorTamper INTEGER,
|
|
vErrEnigmaSecurityLog INTEGER,
|
|
vErrEnigmaSecurityBatteryLowWarning INTEGER,
|
|
vErrEnigmaSecurityLogWarning INTEGER,
|
|
vErrIMBCommFail INTEGER,
|
|
vErrIMBSystemError INTEGER,
|
|
vErrIMBSelfTestError INTEGER,
|
|
vErrIMBCertificateorKey INTEGER,
|
|
vErrIMBICPCommunicationsStatus INTEGER,
|
|
vErrIMBRTCError INTEGER,
|
|
vErrIMBFPGATemperatureoutofrange INTEGER,
|
|
vErrIMBSupplyvoltageoutofrange INTEGER,
|
|
vErrIMBSecurityTamper INTEGER,
|
|
vErrIMBSecurityBatteryEvent INTEGER,
|
|
vErrIMBSecurityEnclosureNotArmed INTEGER,
|
|
vErrIMBPhysicalMarriageTamper INTEGER,
|
|
vErrIMBLogicalMarriageTamper INTEGER,
|
|
vErrIMBMarriageNOTActive INTEGER,
|
|
vErrIMBServiceDoorTamper INTEGER,
|
|
vErrIMBSecurityBatteryLowWarning INTEGER,
|
|
vErrSlaveCommFail INTEGER,
|
|
vErrSlaveStatusFail INTEGER,
|
|
vErrLampLitChange INTEGER,
|
|
vErrSlaveCommAckFail INTEGER,
|
|
vErrLamp1OverTime INTEGER,
|
|
vErrLamp2OverTime INTEGER,
|
|
vErrSensorFailInlet INTEGER,
|
|
vErrSensorFailDMD INTEGER,
|
|
vErrOverTempDMDPrecaution INTEGER,
|
|
vErrOverTempInletPrecaution INTEGER,
|
|
vErrDownLampPowerActivated INTEGER,
|
|
vErrOverTempBallast1Precaution INTEGER,
|
|
vErrOverTempBallast2Precaution INTEGER,
|
|
vErrOverTempDMD INTEGER,
|
|
vErrOverTempInlet INTEGER,
|
|
vErrOverTempLamp INTEGER,
|
|
vErrOverTempBallast1 INTEGER,
|
|
vErrOverTempBallast2 INTEGER,
|
|
vErrInterlockOpen INTEGER,
|
|
vErrSystemI2cFail INTEGER,
|
|
vErrEepromFail INTEGER,
|
|
vErrEepVersionFail INTEGER,
|
|
vErrSoftwareI2cFail INTEGER,
|
|
vErrPreCooling INTEGER,
|
|
vErrLamp1DoorOpen INTEGER,
|
|
vErrLamp2DoorOpen INTEGER,
|
|
vErrBallast1Uart INTEGER,
|
|
vErrBallast2Uart INTEGER,
|
|
vErrFanInit INTEGER,
|
|
vErrExGpioFail INTEGER,
|
|
vErrNotchFilterOpen INTEGER,
|
|
vErrFan15Stop INTEGER,
|
|
vErrFan16Stop INTEGER,
|
|
vErrFan15StopPrecaution INTEGER,
|
|
vErrFan16StopPrecaution INTEGER
|
|
}
|
|
|
|
NCs2ErrorType ::= INTEGER { good(1), bad(2) }
|
|
|
|
vErrLampDoorOpen
|
|
OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(1) Lamp Door Open"
|
|
::= { vSystemErrorInDirectNumber 1
|
|
}
|
|
|
|
vErrLampOverTemp OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(2) Lamp OverTemp."
|
|
::= { vSystemErrorInDirectNumber 2 }
|
|
|
|
vErrGPSU12VFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(4) GPSU (12V) Fail"
|
|
::= { vSystemErrorInDirectNumber 4 }
|
|
|
|
vErrLampUnlit OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(5) Lamp Unlit"
|
|
::= { vSystemErrorInDirectNumber 5 }
|
|
|
|
vErrHouseOverTime OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(6) House OverTime"
|
|
::= { vSystemErrorInDirectNumber 6 }
|
|
|
|
vErrLPSUOverTemp OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(8) LPSU OverTemp."
|
|
::= { vSystemErrorInDirectNumber 8 }
|
|
|
|
vErrE2PROMRFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(12) E2PROM R Fail"
|
|
::= { vSystemErrorInDirectNumber 12 }
|
|
|
|
vErrInterlockFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(13) Interlock Fail"
|
|
::= { vSystemErrorInDirectNumber 13 }
|
|
|
|
vErrE2PROMWFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(15) E2PROM W Fail"
|
|
::= { vSystemErrorInDirectNumber 15 }
|
|
|
|
vErrPumpStop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(17) Pump Stop"
|
|
::= { vSystemErrorInDirectNumber 17 }
|
|
|
|
vErrDLPAckFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(120) DLP Ack Fail"
|
|
::= { vSystemErrorInDirectNumber 120 }
|
|
|
|
vErrLensFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(121) Lens Fail"
|
|
::= { vSystemErrorInDirectNumber 121 }
|
|
|
|
vErrBulbOverTime OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(123) Bulb OverTime"
|
|
::= { vSystemErrorInDirectNumber 123 }
|
|
|
|
vErrLPSUFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(125) LPSU Fail"
|
|
::= { vSystemErrorInDirectNumber 125 }
|
|
|
|
vErrOutRange OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(128) OutRange"
|
|
::= { vSystemErrorInDirectNumber 128 }
|
|
|
|
vErrDownLampPower OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(129) Down Lamp Power"
|
|
::= { vSystemErrorInDirectNumber 129 }
|
|
|
|
vErrMMSCommFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(130) MMS Comm Fail"
|
|
::= { vSystemErrorInDirectNumber 130 }
|
|
|
|
vErrMMSFanStop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(131) MMS Fan Stop"
|
|
::= { vSystemErrorInDirectNumber 131 }
|
|
|
|
vErrMMSFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(132) MMS Fail"
|
|
::= { vSystemErrorInDirectNumber 132 }
|
|
|
|
vErrMMReset OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(133) MM Reset"
|
|
::= { vSystemErrorInDirectNumber 133 }
|
|
|
|
vErrDLPCommRFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(140) DLP CommR Fail"
|
|
::= { vSystemErrorInDirectNumber 140 }
|
|
|
|
vErrDLPCommEFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(141) DLP CommE Fail"
|
|
::= { vSystemErrorInDirectNumber 141 }
|
|
|
|
vErrSensorFailOutsideAir OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(145) SensorFail Outside Air"
|
|
::= { vSystemErrorInDirectNumber 145 }
|
|
|
|
vErrSensorFailLPSUIntake OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(146) SensorFail LPSU Intake"
|
|
::= { vSystemErrorInDirectNumber 146 }
|
|
|
|
vErrSensorFailExhaust OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(147) SensorFail Exhaust"
|
|
::= { vSystemErrorInDirectNumber 147 }
|
|
|
|
vErrSensorFailDMDB OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(148) SensorFail DMD-B"
|
|
::= { vSystemErrorInDirectNumber 148 }
|
|
|
|
vErrFan0Stop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(150) Fan0 Stop"
|
|
::= { vSystemErrorInDirectNumber 150 }
|
|
|
|
vErrFan1Stop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(151) Fan1 Stop"
|
|
::= { vSystemErrorInDirectNumber 151 }
|
|
|
|
vErrFan2Stop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(152) Fan2 Stop"
|
|
::= { vSystemErrorInDirectNumber 152 }
|
|
|
|
vErrFan3Stop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(153) Fan3 Stop"
|
|
::= { vSystemErrorInDirectNumber 153 }
|
|
|
|
vErrFan4Stop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(154) Fan4 Stop"
|
|
::= { vSystemErrorInDirectNumber 154 }
|
|
|
|
vErrFan5Stop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(155) Fan5 Stop"
|
|
::= { vSystemErrorInDirectNumber 155 }
|
|
|
|
vErrFan6Stop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(156) Fan6 Stop"
|
|
::= { vSystemErrorInDirectNumber 156 }
|
|
|
|
vErrFan7Stop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(157) Fan7 Stop"
|
|
::= { vSystemErrorInDirectNumber 157 }
|
|
|
|
vErrFan8Stop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(158) Fan8 Stop"
|
|
::= { vSystemErrorInDirectNumber 158 }
|
|
|
|
vErrFan9Stop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(159) Fan9 Stop"
|
|
::= { vSystemErrorInDirectNumber 159 }
|
|
|
|
vErrGPSUFanStop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(160) GPSU Fan Stop"
|
|
::= { vSystemErrorInDirectNumber 160 }
|
|
|
|
vErrLampFan0Stop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(162) Lamp Fan0 Stop"
|
|
::= { vSystemErrorInDirectNumber 162 }
|
|
|
|
vErrLampFan1Stop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(163) Lamp Fan1 Stop"
|
|
::= { vSystemErrorInDirectNumber 163 }
|
|
|
|
vErrICPFanStop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(164) ICP Fan Stop"
|
|
::= { vSystemErrorInDirectNumber 164 }
|
|
|
|
vErrGPIMACRO OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(165) GPI MACRO Selection Invalid"
|
|
::= { vSystemErrorInDirectNumber 165 }
|
|
|
|
vErrGPIControl OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(166) GPI Control Invalid"
|
|
::= { vSystemErrorInDirectNumber 166 }
|
|
|
|
vErrOverTempOutsideAir OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(170) OverTemp.Outside Air"
|
|
::= { vSystemErrorInDirectNumber 170 }
|
|
|
|
vErrOverTempPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(171) OverTemp Precaution"
|
|
::= { vSystemErrorInDirectNumber 171 }
|
|
|
|
vErrOverTempExhaust OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(172) OverTemp.Exhaust"
|
|
::= { vSystemErrorInDirectNumber 172 }
|
|
|
|
vErrOverTempDMDB OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(173) OverTemp.DMD-B"
|
|
::= { vSystemErrorInDirectNumber 173 }
|
|
|
|
vErrBulbEntry OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(174) Bulb Entry"
|
|
::= { vSystemErrorInDirectNumber 174 }
|
|
|
|
vErrTamperFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(177) Tamper Fail"
|
|
::= { vSystemErrorInDirectNumber 177 }
|
|
|
|
vErrMarriageTamperFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(178) Marriage Tamper Fail"
|
|
::= { vSystemErrorInDirectNumber 178 }
|
|
|
|
vErrCPUFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(180) CPU Fail"
|
|
::= { vSystemErrorInDirectNumber 180 }
|
|
|
|
vErrGPSU24VFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(187) GPSU (24V) Fail"
|
|
::= { vSystemErrorInDirectNumber 187 }
|
|
|
|
vErrLogWriteFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(201) Error Log Write Fail"
|
|
::= { vSystemErrorInDirectNumber 201 }
|
|
|
|
vErrUnknownLPSUModel OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(210) Unknown LPSU Model"
|
|
::= { vSystemErrorInDirectNumber 210 }
|
|
|
|
vErrLPSUFanStop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(211) LPSU Fan Stop"
|
|
::= { vSystemErrorInDirectNumber 211 }
|
|
|
|
vErr12VOutsiderange OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(213) 12V Outside range"
|
|
::= { vSystemErrorInDirectNumber 213 }
|
|
|
|
vErr24VOutsiderange OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(214) 24V Outside range"
|
|
::= { vSystemErrorInDirectNumber 214 }
|
|
|
|
vErrFilterTimeOver OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
NC2000/NC1200/NC3200/NC3240
|
|
(215) Lamp Filter Time Over
|
|
NC900
|
|
(215) Filter Time Over"
|
|
::= { vSystemErrorInDirectNumber 215 }
|
|
|
|
vErrBodyFilterTimeOver OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(216) Body Filter Time Over"
|
|
::= { vSystemErrorInDirectNumber 216 }
|
|
|
|
vErrFanExchangeTime OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
NC2000/NC1200/NC3200/NC3240
|
|
(220) AC On Fan Exchange Time
|
|
NC900
|
|
(220) Fan Exchange Time"
|
|
::= { vSystemErrorInDirectNumber 220 }
|
|
|
|
vErrPowerOnFanExchangeTime OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(221) Power On Fan Exchange Time"
|
|
::= { vSystemErrorInDirectNumber 221 }
|
|
|
|
vErrLampFanExchangeTime OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(222) Lamp Fan Exchange Time"
|
|
::= { vSystemErrorInDirectNumber 222 }
|
|
|
|
vErrRouterFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(230) Router Fail"
|
|
::= { vSystemErrorInDirectNumber 230 }
|
|
|
|
vErrSensorFailOpt OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(231) SensorFail Opt"
|
|
::= { vSystemErrorInDirectNumber 231 }
|
|
|
|
vErrMACWriteFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(232) MAC Write Fail"
|
|
::= { vSystemErrorInDirectNumber 232 }
|
|
|
|
vErrIllegalMACAddress OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(233) Illegal MAC Address"
|
|
::= { vSystemErrorInDirectNumber 233 }
|
|
|
|
vErrRouterSelfCheckFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(235) Router Self Check Fail"
|
|
::= { vSystemErrorInDirectNumber 235 }
|
|
|
|
vErrRouterFirmwareUpdateFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(236) Router Firmware Update Fail"
|
|
::= { vSystemErrorInDirectNumber 236 }
|
|
|
|
vErrSIBCommFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(240) SIB Comm Fail"
|
|
::= { vSystemErrorInDirectNumber 240 }
|
|
|
|
vErrSIBError OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(241) SIB Error"
|
|
::= { vSystemErrorInDirectNumber 241 }
|
|
|
|
vErrSIBFPGAReboot OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(242) SIB FPGA Reboot"
|
|
::= { vSystemErrorInDirectNumber 242 }
|
|
|
|
vErrFan10Stop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(245) Fan10 Stop"
|
|
::= { vSystemErrorInDirectNumber 245 }
|
|
|
|
vErrFan11Stop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(246) Fan11 Stop"
|
|
::= { vSystemErrorInDirectNumber 246 }
|
|
|
|
vErrFan12Stop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(247) Fan12 Stop"
|
|
::= { vSystemErrorInDirectNumber 247 }
|
|
|
|
vErrFan13Stop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(248) Fan13 Stop"
|
|
::= { vSystemErrorInDirectNumber 248 }
|
|
|
|
vErrFan14Stop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(249) Fan14 Stop"
|
|
::= { vSystemErrorInDirectNumber 249 }
|
|
|
|
vErrFan0StopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(250) Fan0 Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 250 }
|
|
|
|
vErrFan1StopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(251) Fan1 Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 251 }
|
|
|
|
vErrFan2StopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(252) Fan2 Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 252 }
|
|
|
|
vErrFan3StopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(253) Fan3 Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 253 }
|
|
|
|
vErrFan4StopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(254) Fan4 Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 254 }
|
|
|
|
vErrFan5StopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(255) Fan5 Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 255 }
|
|
|
|
vErrFan6StopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(256) Fan6 Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 256 }
|
|
|
|
vErrFan7StopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(257) Fan7 Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 257 }
|
|
|
|
vErrFan8StopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(258) Fan8 Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 258 }
|
|
|
|
vErrFan9StopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(259) Fan9 Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 259 }
|
|
|
|
vErrLampFan0StopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(260) Lamp Fan0 Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 260 }
|
|
|
|
vErrLampFan1StopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(261) Lamp Fan1 Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 261 }
|
|
|
|
vErrPumpStopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(262) Pump Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 262 }
|
|
|
|
vErrICPFanStopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(263) ICP Fan Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 263 }
|
|
|
|
vErrFan10StopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(264) Fan10 Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 264 }
|
|
|
|
vErrFan11StopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(265) Fan11 Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 265 }
|
|
|
|
vErrFan12StopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(266) Fan12 Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 266 }
|
|
|
|
vErrFan13StopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(267) Fan13 Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 267 }
|
|
|
|
vErrFan14StopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(268) Fan14 Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 268 }
|
|
|
|
vErrSDTamperTerminate OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(270) SD Tamper Terminate"
|
|
::= { vSystemErrorInDirectNumber 270 }
|
|
|
|
vErrIMBSDTamperTerminate OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(271) IMB:SD Tamper Terminate"
|
|
::= { vSystemErrorInDirectNumber 271 }
|
|
|
|
vErrBulbWarrantyOver OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(280) Bulb Warranty Over"
|
|
::= { vSystemErrorInDirectNumber 280 }
|
|
|
|
vErrSystemError OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(301) System Error"
|
|
::= { vSystemErrorInDirectNumber 301 }
|
|
|
|
vErrSelfTestError OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(302) Self Test Error"
|
|
::= { vSystemErrorInDirectNumber 302 }
|
|
|
|
vErrInstallReleasePackage OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(303) Install Release Package Error"
|
|
::= { vSystemErrorInDirectNumber 303 }
|
|
|
|
vErrLoadReleasePackage OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(304) Load Release Package Error"
|
|
::= { vSystemErrorInDirectNumber 304 }
|
|
|
|
vErrKeyError OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(305) Key Error"
|
|
::= { vSystemErrorInDirectNumber 305 }
|
|
|
|
vErrCertificateError OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(306) Certificate Error"
|
|
::= { vSystemErrorInDirectNumber 306 }
|
|
|
|
vErrICPNormalConfiguration OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(317) ICP Normal Configuration Error"
|
|
::= { vSystemErrorInDirectNumber 317 }
|
|
|
|
vErrICPBootConfiguration OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(318) ICP Boot Configuration Error"
|
|
::= { vSystemErrorInDirectNumber 318 }
|
|
|
|
vErrFMTNormalConfiguration OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(319) FMT Normal Configuration Error"
|
|
::= { vSystemErrorInDirectNumber 319 }
|
|
|
|
vErrFMTBootConfiguration OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(320) FMT Boot Configuration Error"
|
|
::= { vSystemErrorInDirectNumber 320 }
|
|
|
|
vErrFMTSatelliteConfiguration OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(321) FMT Satellite Configuration Error"
|
|
::= { vSystemErrorInDirectNumber 321 }
|
|
|
|
vErr120VSupplyoutofrange OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(322) 1.20V Supply out of range"
|
|
::= { vSystemErrorInDirectNumber 322 }
|
|
|
|
vErr180VSupplyoutofrange OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(323) 1.80V Supply out of range"
|
|
::= { vSystemErrorInDirectNumber 323 }
|
|
|
|
vErr250VSupplyoutofrange OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(324) 2.50V Supply out of range"
|
|
::= { vSystemErrorInDirectNumber 324 }
|
|
|
|
vErr330VRegulatoroutofrange OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(325) 3.30V Regulator out of range"
|
|
::= { vSystemErrorInDirectNumber 325 }
|
|
|
|
vErrICPFPGATemperatureoutofrange OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(326) ICP FPGA Temperature out of range"
|
|
::= { vSystemErrorInDirectNumber 326 }
|
|
|
|
vErrFMTFPGATemperatureoutofrange OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(327) FMT FPGA Temperature out of range"
|
|
::= { vSystemErrorInDirectNumber 327 }
|
|
|
|
vErrICPFlashUpdate OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(328) ICP Flash Update Error"
|
|
::= { vSystemErrorInDirectNumber 328 }
|
|
|
|
vErrFMTSequenceDataFileMismatch OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(329) FMT Sequence Data File Mismatch"
|
|
::= { vSystemErrorInDirectNumber 329 }
|
|
|
|
vErrFMTDMDDataFileMismatch OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(330) FMT DMD Data File Mismatch"
|
|
::= { vSystemErrorInDirectNumber 330 }
|
|
|
|
vErrFMTFlashChecksumSequenceData OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(331) FMT Flash Checksum Error - Sequence Data"
|
|
::= { vSystemErrorInDirectNumber 331 }
|
|
|
|
vErrFMTFlashChecksumDMDData OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(332) FMT Flash Checksum Error - DMD Data"
|
|
::= { vSystemErrorInDirectNumber 332 }
|
|
|
|
vErrSatelliteHardwareMismatch OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(333) Satellite Hardware Mismatch"
|
|
::= { vSystemErrorInDirectNumber 333 }
|
|
|
|
vErrFMTFlashUpdate OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(334) FMT Flash Update Error"
|
|
::= { vSystemErrorInDirectNumber 334 }
|
|
|
|
vErrRedSatelliteReportsReset OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(335) Red Satellite Reports Reset"
|
|
::= { vSystemErrorInDirectNumber 335 }
|
|
|
|
vErrRedSatelliteSerialLink OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(336) Red Satellite Serial Link Error"
|
|
::= { vSystemErrorInDirectNumber 336 }
|
|
|
|
vErrRedSatelliteFirmwareConfiguration OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(337) Red Satellite Firmware Configuration Error"
|
|
::= { vSystemErrorInDirectNumber 337 }
|
|
|
|
vErrRedDAD1000BiasUnderVoltage OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(338) Red DAD1000 Bias Under Voltage Error"
|
|
::= { vSystemErrorInDirectNumber 338 }
|
|
|
|
vErrRedDAD1000ResetUnderVoltage OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(339) Red DAD1000 Reset Under Voltage Error"
|
|
::= { vSystemErrorInDirectNumber 339 }
|
|
|
|
vErrRedDAD1000OffsetUnderVoltage OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(340) Red DAD1000 Offset Under Voltage Error"
|
|
::= { vSystemErrorInDirectNumber 340 }
|
|
|
|
vErrRedDAD1000ThermalShutdown OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(341) Red DAD1000 Thermal Shutdown Error"
|
|
::= { vSystemErrorInDirectNumber 341 }
|
|
|
|
vErrGreenSatelliteReportsReset OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(342) Green Satellite Reports Reset"
|
|
::= { vSystemErrorInDirectNumber 342 }
|
|
|
|
vErrGreenSatelliteSerialLink OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(343) Green Satellite Serial Link Error"
|
|
::= { vSystemErrorInDirectNumber 343 }
|
|
|
|
vErrGreenSatelliteFirmwareConfiguration OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(344) Green Satellite Firmware Configuration Error"
|
|
::= { vSystemErrorInDirectNumber 344 }
|
|
|
|
vErrGreenDAD1000BiasUnderVoltage OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(345) Green DAD1000 Bias Under Voltage Error"
|
|
::= { vSystemErrorInDirectNumber 345 }
|
|
|
|
vErrGreenDAD1000ResetUnderVoltage OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(346) Green DAD1000 Reset Under Voltage Error"
|
|
::= { vSystemErrorInDirectNumber 346 }
|
|
|
|
vErrGreenDAD1000OffsetUnderVoltage OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(347) Green DAD1000 Offset Under Voltage Error"
|
|
::= { vSystemErrorInDirectNumber 347 }
|
|
|
|
vErrGreenDAD1000ThermalShutdown OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(348) Green DAD1000 Thermal Shutdown Error"
|
|
::= { vSystemErrorInDirectNumber 348 }
|
|
|
|
vErrBlueSatelliteReportsReset OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(349) Blue Satellite Reports Reset"
|
|
::= { vSystemErrorInDirectNumber 349 }
|
|
|
|
vErrBlueSatelliteSerialLink OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(350) Blue Satellite Serial Link Error"
|
|
::= { vSystemErrorInDirectNumber 350 }
|
|
|
|
vErrBlueSatelliteFirmwareConfiguration OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(351) Blue Satellite Firmware Configuration Error"
|
|
::= { vSystemErrorInDirectNumber 351 }
|
|
|
|
vErrBlueDAD1000BiasUnderVoltage OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(352) Blue DAD1000 Bias Under Voltage Error"
|
|
::= { vSystemErrorInDirectNumber 352 }
|
|
|
|
vErrBlueDAD1000ResetUnderVoltage OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(353) Blue DAD1000 Reset Under Voltage Error"
|
|
::= { vSystemErrorInDirectNumber 353 }
|
|
|
|
vErrBlueDAD1000OffsetUnderVoltage OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(354) Blue DAD1000 Offset Under Voltage Error"
|
|
::= { vSystemErrorInDirectNumber 354 }
|
|
|
|
vErrBlueDAD1000ThermalShutdown OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(355) Blue DAD1000 Thermal Shutdown Error"
|
|
::= { vSystemErrorInDirectNumber 355 }
|
|
|
|
vErrRTCError OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(356) RTC Error"
|
|
::= { vSystemErrorInDirectNumber 356 }
|
|
|
|
vErrICPFrameMemoryTestResult OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(370) ICP Frame Memory Test Result Fail"
|
|
::= { vSystemErrorInDirectNumber 370 }
|
|
|
|
vErrICPDataPathSignatureTestResult OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(372) ICP Data Path Signature Test Result Fail"
|
|
::= { vSystemErrorInDirectNumber 372 }
|
|
|
|
vErrEnigmaCommFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(400) Enigma Comm Fail"
|
|
::= { vSystemErrorInDirectNumber 400 }
|
|
|
|
vErrEnigmaSystemError OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(410) System Error"
|
|
::= { vSystemErrorInDirectNumber 410 }
|
|
|
|
vErrEnigmaSelfTestError OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(411) Self Test Error"
|
|
::= { vSystemErrorInDirectNumber 411 }
|
|
|
|
vErrEnigmaInstallReleasePackage OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(412) Install Release Package Error"
|
|
::= { vSystemErrorInDirectNumber 412 }
|
|
|
|
vErrEnigmaLoadReleasePackage OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(413) Load Release Package Error"
|
|
::= { vSystemErrorInDirectNumber 413 }
|
|
|
|
vErrEnigmaTILoginListPackage OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(414) TI Login List Package Error"
|
|
::= { vSystemErrorInDirectNumber 414 }
|
|
|
|
vErrEnigmaSecurityOfficerLoginListPackage OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(415) Security Officer Login List Package Error"
|
|
::= { vSystemErrorInDirectNumber 415 }
|
|
|
|
vErrEnigmaCertificateorKey OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(419) Certificate or Key Error"
|
|
::= { vSystemErrorInDirectNumber 419 }
|
|
|
|
vErrEnigmaICPCommunicationsStatus OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(420) ICP Communications Status"
|
|
::= { vSystemErrorInDirectNumber 420 }
|
|
|
|
vErrEnigmaUserLoaderIntegrity OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(426) User Loader Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 426 }
|
|
|
|
vErrEnigmaMainApplicationIntegrity OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(427) Main Application Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 427 }
|
|
|
|
vErrEnigmaRNGHardwareIntegrity OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(428) RNG Hardware Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 428 }
|
|
|
|
vErrEnigmaDRNGAlgorithmIntegrity OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(429) DRNG Algorithm Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 429 }
|
|
|
|
vErrEnigmaRSAAlgorithmIntegrity OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(430) RSA Algorithm Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 430 }
|
|
|
|
vErrEnigmaAESAlgorithmIntegrity OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(431) AES Algorithm Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 431 }
|
|
|
|
vErrEnigmaHMACAlgorithmIntegrity OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(432) HMAC Algorithm Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 432 }
|
|
|
|
vErrEnigmaSHAAlgorithmIntegrity OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(433) SHA Algorithm Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 433 }
|
|
|
|
vErrEnigmaTLSIntegrity OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(434) TLS Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 434 }
|
|
|
|
vErrEnigmaFPGAConfigurationIntegrity OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(435) FPGA Configuration Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 435 }
|
|
|
|
vErrEnigmaFPGACineLink2 OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(436) FPGA CineLink 2 Decryption Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 436 }
|
|
|
|
vErrEnigmaRTCError OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(437) RTC Error"
|
|
::= { vSystemErrorInDirectNumber 437 }
|
|
|
|
vErrEnigmaFPGAConfiguration OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(442) FPGA Configuration Error"
|
|
::= { vSystemErrorInDirectNumber 442 }
|
|
|
|
vErrEnigmaFPGATemperatureoutofrange OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(443) FPGA Temperature out of range"
|
|
::= { vSystemErrorInDirectNumber 443 }
|
|
|
|
vErrEnigmaRNGHardwareDuplicateOutput OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(446) RNG Hardware Duplicate Output Error"
|
|
::= { vSystemErrorInDirectNumber 446 }
|
|
|
|
vErrEnigmaDRNGAlgorithmDuplicateOutput OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(447) DRNG Algorithm Duplicate Output Error"
|
|
::= { vSystemErrorInDirectNumber 447 }
|
|
|
|
vErrEnigma120VSupplyoutofrange OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(450) 1.20V Supply out of range"
|
|
::= { vSystemErrorInDirectNumber 450 }
|
|
|
|
vErrEnigma180VSupplyoutofrange OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(451) 1.80V Supply out of range"
|
|
::= { vSystemErrorInDirectNumber 451 }
|
|
|
|
vErrEnigma250VSupplyoutofrange OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(452) 2.50V Supply out of range"
|
|
::= { vSystemErrorInDirectNumber 452 }
|
|
|
|
vErrEnigma330VRegulatoroutofrange OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(453) 3.30V Regulator out of range"
|
|
::= { vSystemErrorInDirectNumber 453 }
|
|
|
|
vErrEnigmaSelfTestUserLoader OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(458) SelfTest User Loader Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 458 }
|
|
|
|
vErrEnigmaSelfTestMainApplication OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(459) SelfTest Main Application Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 459 }
|
|
|
|
vErrEnigmaSelfTestRNGHardware OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(460) SelfTest RNG Hardware Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 460 }
|
|
|
|
vErrEnigmaSelfTestDRNGAlgorithm OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(461) SelfTest DRNG Algorithm Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 461 }
|
|
|
|
vErrEnigmaSelfTestRSAAlgorithm OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(462) SelfTest RSA Algorithm Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 462 }
|
|
|
|
vErrEnigmaSelfTestAESAlgorithm OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(463) SelfTest AES Algorithm Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 463 }
|
|
|
|
vErrEnigmaSelfTestHMACAlgorithm OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(464) SelfTest HMAC Algorithm Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 464 }
|
|
|
|
vErrEnigmaSelfTestSHAAlgorithm OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(465) SelfTest SHA Algorithm Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 465 }
|
|
|
|
vErrEnigmaSelfTestTLSIntegrity OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(466) SelfTest TLS Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 466 }
|
|
|
|
vErrEnigmaSelfTestFPGAConfiguration OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(467) SelfTest FPGA Configuration Integrity Error"
|
|
::= { vSystemErrorInDirectNumber 467 }
|
|
|
|
vErrEnigmaSelfTestFPGACineLink2 OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(468) SelfTest FPGA CineLink. 2 Decryption Integrit"
|
|
::= { vSystemErrorInDirectNumber 468 }
|
|
|
|
vErrEnigmaSecurityTamper OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(474) Security Tamper"
|
|
::= { vSystemErrorInDirectNumber 474 }
|
|
|
|
vErrEnigmaTopSideSecurityEnclosureOpen OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(475) Top Side Security Enclosure Open"
|
|
::= { vSystemErrorInDirectNumber 475 }
|
|
|
|
vErrEnigmaBottomSideSecurityEnclosureOpen OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(476) Bottom Side Security Enclosure Open"
|
|
::= { vSystemErrorInDirectNumber 476 }
|
|
|
|
vErrEnigmaSecurityBatteryEvent OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(477) Security Battery Event"
|
|
::= { vSystemErrorInDirectNumber 477 }
|
|
|
|
vErrEnigmaSoftwareCommandedZeroization OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(478) Software Commanded Zeroization"
|
|
::= { vSystemErrorInDirectNumber 478 }
|
|
|
|
vErrEnigmaSecurityEnclosureNotArmed OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(481) Security Enclosure Not Armed"
|
|
::= { vSystemErrorInDirectNumber 481 }
|
|
|
|
vErrEnigmaPhysicalMarriageTamper OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(482) Physical Marriage Tamper"
|
|
::= { vSystemErrorInDirectNumber 482 }
|
|
|
|
vErrEnigmaLogicalMarriageTamper OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(483) Logical Marriage Tamper"
|
|
::= { vSystemErrorInDirectNumber 483 }
|
|
|
|
vErrEnigmaMarriageNOTActive OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(484) Marriage NOT Active"
|
|
::= { vSystemErrorInDirectNumber 484 }
|
|
|
|
vErrEnigmaServiceDoorTamper OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(486) Service Door Tamper"
|
|
::= { vSystemErrorInDirectNumber 486 }
|
|
|
|
vErrEnigmaSecurityLog OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(487) Security Log Error"
|
|
::= { vSystemErrorInDirectNumber 487 }
|
|
|
|
vErrEnigmaSecurityBatteryLowWarning OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(488) Security Battery Low Warning"
|
|
::= { vSystemErrorInDirectNumber 488 }
|
|
|
|
vErrEnigmaSecurityLogWarning OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(489) Security Log Warning"
|
|
::= { vSystemErrorInDirectNumber 489 }
|
|
|
|
vErrIMBCommFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(500) IMB Comm Fail"
|
|
::= { vSystemErrorInDirectNumber 500 }
|
|
|
|
vErrIMBSystemError OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(510) IMB:System Error"
|
|
::= { vSystemErrorInDirectNumber 510 }
|
|
|
|
vErrIMBSelfTestError OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(511) IMB:Self Test Error"
|
|
::= { vSystemErrorInDirectNumber 511 }
|
|
|
|
vErrIMBCertificateorKey OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(519) IMB:Certificate or Key Error"
|
|
::= { vSystemErrorInDirectNumber 519 }
|
|
|
|
vErrIMBICPCommunicationsStatus OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(520) IMB:ICP Communications Status"
|
|
::= { vSystemErrorInDirectNumber 520 }
|
|
|
|
vErrIMBRTCError OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(537) IMB:RTC Error"
|
|
::= { vSystemErrorInDirectNumber 537 }
|
|
|
|
vErrIMBFPGATemperatureoutofrange OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(543) IMB:FPGA Temperature out of range"
|
|
::= { vSystemErrorInDirectNumber 543 }
|
|
|
|
vErrIMBSupplyvoltageoutofrange OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(550) IMB:Supply voltage out of range"
|
|
::= { vSystemErrorInDirectNumber 550 }
|
|
|
|
vErrIMBSecurityTamper OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(574) IMB:Security Tamper"
|
|
::= { vSystemErrorInDirectNumber 574 }
|
|
|
|
vErrIMBSecurityBatteryEvent OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(577) IMB:Security Battery Event"
|
|
::= { vSystemErrorInDirectNumber 577 }
|
|
|
|
vErrIMBSecurityEnclosureNotArmed OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(581) IMB:Security Enclosure Not Armed"
|
|
::= { vSystemErrorInDirectNumber 581 }
|
|
|
|
vErrIMBPhysicalMarriageTamper OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(582) IMB:Physical Marriage Tamper"
|
|
::= { vSystemErrorInDirectNumber 582 }
|
|
|
|
vErrIMBLogicalMarriageTamper OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(583) IMB:Logical Marriage Tamper"
|
|
::= { vSystemErrorInDirectNumber 583 }
|
|
|
|
vErrIMBMarriageNOTActive OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(584) IMB:Marriage NOT Active"
|
|
::= { vSystemErrorInDirectNumber 584 }
|
|
|
|
vErrIMBServiceDoorTamper OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(586) IMB:Service Door Tamper"
|
|
::= { vSystemErrorInDirectNumber 586 }
|
|
|
|
vErrIMBSecurityBatteryLowWarning OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(588) IMB:Security Battery Low Warning"
|
|
::= { vSystemErrorInDirectNumber 588 }
|
|
|
|
vErrSlaveCommFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(700) Slave Comm Fail"
|
|
::= { vSystemErrorInDirectNumber 700 }
|
|
|
|
vErrSlaveStatusFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(701) Slave Status Fail"
|
|
::= { vSystemErrorInDirectNumber 701 }
|
|
|
|
vErrLampLitChange OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(702) Lamp Lit Change"
|
|
::= { vSystemErrorInDirectNumber 702 }
|
|
|
|
vErrSlaveCommAckFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(703) Slave Comm Ack Fail"
|
|
::= { vSystemErrorInDirectNumber 703 }
|
|
|
|
vErrLamp1OverTime OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(710) Lamp1 OverTime"
|
|
::= { vSystemErrorInDirectNumber 710 }
|
|
|
|
vErrLamp2OverTime OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(711) Lamp2 OverTime"
|
|
::= { vSystemErrorInDirectNumber 711 }
|
|
|
|
vErrSensorFailInlet OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(740) SensorFail Inlet"
|
|
::= { vSystemErrorInDirectNumber 740 }
|
|
|
|
vErrSensorFailDMD OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(741) SensorFail DMD"
|
|
::= { vSystemErrorInDirectNumber 741 }
|
|
|
|
vErrOverTempDMDPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(750) OverTemp.DMD Precaution"
|
|
::= { vSystemErrorInDirectNumber 750 }
|
|
|
|
vErrOverTempInletPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(751) OverTemp.Inlet Precaution"
|
|
::= { vSystemErrorInDirectNumber 751 }
|
|
|
|
vErrDownLampPowerActivated OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(752) Down Lamp Power Activated"
|
|
::= { vSystemErrorInDirectNumber 752 }
|
|
|
|
vErrOverTempBallast1Precaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(753) OverTemp.Ballast1 Precaution"
|
|
::= { vSystemErrorInDirectNumber 753 }
|
|
|
|
vErrOverTempBallast2Precaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(754) OverTemp.Ballast2 Precaution"
|
|
::= { vSystemErrorInDirectNumber 754 }
|
|
|
|
vErrOverTempDMD OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(760) OverTemp.DMD"
|
|
::= { vSystemErrorInDirectNumber 760 }
|
|
|
|
vErrOverTempInlet OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(761) OverTemp.Inlet"
|
|
::= { vSystemErrorInDirectNumber 761 }
|
|
|
|
vErrOverTempLamp OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(762) OverTemp.Lamp"
|
|
::= { vSystemErrorInDirectNumber 762 }
|
|
|
|
vErrOverTempBallast1 OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(764) OverTemp.Ballast1"
|
|
::= { vSystemErrorInDirectNumber 764 }
|
|
|
|
vErrOverTempBallast2 OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(765) OverTemp.Ballast2"
|
|
::= { vSystemErrorInDirectNumber 765 }
|
|
|
|
vErrInterlockOpen OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(781) Interlock Open"
|
|
::= { vSystemErrorInDirectNumber 781 }
|
|
|
|
vErrSystemI2cFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(782) SystemI2cFail"
|
|
::= { vSystemErrorInDirectNumber 782 }
|
|
|
|
vErrEepromFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(783) EepromFail"
|
|
::= { vSystemErrorInDirectNumber 783 }
|
|
|
|
vErrEepVersionFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(784) EepVersionFail"
|
|
::= { vSystemErrorInDirectNumber 784 }
|
|
|
|
vErrSoftwareI2cFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(785) SoftwareI2cFail"
|
|
::= { vSystemErrorInDirectNumber 785 }
|
|
|
|
vErrPreCooling OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(786) PreCooling"
|
|
::= { vSystemErrorInDirectNumber 786 }
|
|
|
|
vErrLamp1DoorOpen OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(787) Lamp1 Door Open"
|
|
::= { vSystemErrorInDirectNumber 787 }
|
|
|
|
vErrLamp2DoorOpen OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(788) Lamp2 Door Open"
|
|
::= { vSystemErrorInDirectNumber 788 }
|
|
|
|
vErrBallast1Uart OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(789) Ballast1UartError"
|
|
::= { vSystemErrorInDirectNumber 789 }
|
|
|
|
vErrBallast2Uart OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(790) Ballast2UartError"
|
|
::= { vSystemErrorInDirectNumber 790 }
|
|
|
|
vErrFanInit OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(791) FanInitError"
|
|
::= { vSystemErrorInDirectNumber 791 }
|
|
|
|
vErrExGpioFail OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(792) ExGpioFail"
|
|
::= { vSystemErrorInDirectNumber 792 }
|
|
|
|
vErrNotchFilterOpen OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(793) Notch Filter Open"
|
|
::= { vSystemErrorInDirectNumber 793 }
|
|
|
|
vErrFan15Stop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(800) Fan15 Stop"
|
|
::= { vSystemErrorInDirectNumber 800 }
|
|
|
|
vErrFan16Stop OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(801) Fan16 Stop"
|
|
::= { vSystemErrorInDirectNumber 801 }
|
|
|
|
vErrFan15StopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(810) Fan15 Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 810 }
|
|
|
|
vErrFan16StopPrecaution OBJECT-TYPE
|
|
SYNTAX NCs2ErrorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error status of specified number.
|
|
(811) Fan16 Stop Precaution"
|
|
::= { vSystemErrorInDirectNumber 811 }
|
|
|
|
--<< vSystem 9 >>--
|
|
vNetwork OBJECT IDENTIFIER ::= { vSystem 9 }
|
|
|
|
vSystemIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The IP address for the projector system."
|
|
::= { vNetwork 1 }
|
|
|
|
vCinemaIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The IP address for the cinema boards."
|
|
::= { vNetwork 2 }
|
|
|
|
vCardIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The IP address for the PC Card."
|
|
::= { vNetwork 3 }
|
|
|
|
--<< vSystem 10 >>--
|
|
vSetupDate OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..11))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The date when the projector was setup.
|
|
Format : `YYYY/MM/DD' + NULL
|
|
YYYY : Year
|
|
MM : Month
|
|
DD : Date"
|
|
::= { vSystem 10 }
|
|
|
|
--<< vSystem 11 >>--
|
|
vOptionSlotStatus OBJECT IDENTIFIER ::= { vSystem 11 }
|
|
|
|
vSlotB OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
boardNone(1),
|
|
boardSIB(4),
|
|
boardIMB(5),
|
|
boardMMS(6),
|
|
boardSIB2(7),
|
|
boardNoSIB(14),
|
|
boardNoIMB(15),
|
|
boardNoMMS(16),
|
|
boardNoSIB2(17),
|
|
boardNotAvailable(20)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of option board in the slot-B.
|
|
boardNone : No Board
|
|
boardSIB : NC-80LB
|
|
boardIMB : IMB
|
|
boardMMS : MM3000B
|
|
boardSIB2 : NC-80DS
|
|
boardNotAvailable : Not Available"
|
|
|
|
::= { vOptionSlotStatus 1 }
|
|
|
|
vSlotA OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
boardNone(1),
|
|
boardSIB(4),
|
|
boardIMB(5),
|
|
boardMMS(6),
|
|
boardSIB2(7),
|
|
boardNoSIB(14),
|
|
boardNoIMB(15),
|
|
boardNoMMS(16),
|
|
boardNoSIB2(17),
|
|
boardNotAvailable(20)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of option board in the slot-A.
|
|
boardNone : No Board
|
|
boardSIB : NC-80LB
|
|
boardIMB : IMB
|
|
boardMMS : MM3000B
|
|
boardSIB2 : NC-80DS
|
|
boardNotAvailable : Not Available"
|
|
::= { vOptionSlotStatus 2 }
|
|
|
|
--<< vSystem 12 >>--
|
|
vBoardInfo OBJECT IDENTIFIER ::= { vSystem 12 }
|
|
|
|
vSerialNoPJ OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The serial number of the projector system."
|
|
::= { vBoardInfo 1 }
|
|
|
|
vSerialNoMMS OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The serial number of the MMS."
|
|
::= { vBoardInfo 2 }
|
|
|
|
vSerialNoICP OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The serial number of the ICP board."
|
|
::= { vBoardInfo 3 }
|
|
|
|
vSerialNoEnigma OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The serial number of the Enigma board."
|
|
::= { vBoardInfo 4 }
|
|
|
|
vVerPJ OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The version of the projector system."
|
|
::= { vBoardInfo 5 }
|
|
|
|
vVerMMS OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The version of MMS."
|
|
::= { vBoardInfo 6 }
|
|
|
|
vVerICP OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The version of the ICP board.
|
|
(ICP Work Version)"
|
|
::= { vBoardInfo 7 }
|
|
|
|
vVerICPLoginList OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The login list version in the ICP board.
|
|
(ICP Login List Version)"
|
|
::= { vBoardInfo 8 }
|
|
|
|
vVerSIB OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The version of the SIB board.
|
|
(SIB Main Version)"
|
|
::= { vBoardInfo 9 }
|
|
|
|
vVerEnigma OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The version of the Enigma board.
|
|
(Enigma Version)"
|
|
::= { vBoardInfo 10 }
|
|
|
|
vVerEnigmaSOList OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The SOL version of the Enigma board.
|
|
(Enigma Security Officer List Version)"
|
|
::= { vBoardInfo 11 }
|
|
|
|
vVerSlave OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "MCU firmware version of the Slave board."
|
|
::= { vBoardInfo 12 }
|
|
|
|
vVerBallast1 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The Ballast1 version of the Slave board."
|
|
::= { vBoardInfo 13 }
|
|
|
|
vVerBallast2 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The Ballast2 version of the Slave board."
|
|
::= { vBoardInfo 14 }
|
|
|
|
vICPdnQualifier OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..495))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The DN Qualifier attribute in the certificate
|
|
of the ICP board."
|
|
::= { vBoardInfo 15 }
|
|
|
|
vEnigmadnQualifier OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..495))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The DN Qualifier attribute in the certificate
|
|
of the Enigma board."
|
|
::= { vBoardInfo 16 }
|
|
|
|
--<< vSystem 13 >>--
|
|
vModelName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the model name of the projector."
|
|
::= { vSystem 13 }
|
|
|
|
--<< vSystem 14 >>--
|
|
vSystemPowerSupply OBJECT IDENTIFIER ::= { vSystem 14 }
|
|
|
|
vSystemPS3V OBJECT-TYPE
|
|
SYNTAX INTEGER(-1..999)
|
|
UNITS "x0.1V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current value of power supply 3.3V.
|
|
If this value is -1, it means can not get power supply.(error occured)"
|
|
::= { vSystemPowerSupply 1 }
|
|
|
|
vSystemPS5V OBJECT-TYPE
|
|
SYNTAX INTEGER(-1..999)
|
|
UNITS "x0.1V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current value of power supply 5V.
|
|
If this value is -1, it means can not get power supply.(error occured)"
|
|
::= { vSystemPowerSupply 2 }
|
|
|
|
vSystemPS12V OBJECT-TYPE
|
|
SYNTAX INTEGER(-1..999)
|
|
UNITS "x0.1V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current value of power supply 12V.
|
|
If this value is -1, it means can not get power supply.(error occured)"
|
|
::= { vSystemPowerSupply 3 }
|
|
|
|
vSystemPS24V OBJECT-TYPE
|
|
SYNTAX INTEGER(-1..999)
|
|
UNITS "x0.1V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current value of power supply 24V.
|
|
If this value is -1, it means can not get power supply.(error occured)"
|
|
::= { vSystemPowerSupply 4 }
|
|
|
|
--<< vSystem 15 >>--
|
|
vSystemFanSpeed OBJECT IDENTIFIER ::= { vSystem 15 }
|
|
|
|
vSystemFSFan0 OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Fan0.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 1 }
|
|
|
|
vSystemFSFan1 OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Fan1.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 2 }
|
|
|
|
vSystemFSFan2 OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Fan2.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 3 }
|
|
|
|
vSystemFSFan3 OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Fan3.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 4 }
|
|
|
|
vSystemFSFan4 OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Fan4.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 5 }
|
|
|
|
vSystemFSFan5 OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Fan5.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 6 }
|
|
|
|
vSystemFSFan6 OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Fan6.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 7 }
|
|
|
|
vSystemFSFan7 OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Fan7.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 8 }
|
|
|
|
vSystemFSFan8 OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Fan8.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 9 }
|
|
|
|
vSystemFSFan9 OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Fan9.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 10 }
|
|
|
|
vSystemFSFan10 OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Fan10.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 11 }
|
|
|
|
vSystemFSFan11 OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Fan11.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 12 }
|
|
|
|
vSystemFSFan12 OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Fan12.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 13 }
|
|
|
|
vSystemFSLampCoolingFan0 OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Lamp Cooling Fan0.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 14 }
|
|
|
|
vSystemFSLampCoolingFan1 OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Lamp Cooling Fan1.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 15 }
|
|
|
|
vSystemFSPump OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Pump.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 16 }
|
|
|
|
vSystemFSICPFan OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of ICP Fan.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 17 }
|
|
|
|
vSystemFSFan13 OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Fan13.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 18 }
|
|
|
|
vSystemFSFan14 OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Fan14.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 19 }
|
|
|
|
vSystemFSFan15 OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Fan15.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 20 }
|
|
|
|
vSystemFSFan16 OBJECT-TYPE
|
|
SYNTAX INTEGER(-3..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan speed of Fan16.
|
|
If this value is -1, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)
|
|
If this value is -3, it means can not get a fan speed.(overflow)"
|
|
::= { vSystemFanSpeed 21 }
|
|
|
|
--<< vSystem 16 >>--
|
|
vSystemSetting OBJECT IDENTIFIER ::= { vSystem 16 }
|
|
|
|
--<< vSystem.vSystemSetting 1 >>--
|
|
vLANSetting OBJECT IDENTIFIER ::= { vSystemSetting 1 }
|
|
|
|
vDHCP OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual(1),
|
|
automatic(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "LAN Settings for the projector system.( DHCP )
|
|
( To keep setting value in temporary area. When you write the
|
|
vSettingApply, the setting is available.)"
|
|
::= { vLANSetting 1 }
|
|
|
|
vIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "LAN Settings for the projector system.( System IP Address )
|
|
( To keep setting value in temporary area. When you write the
|
|
vSettingApply, the setting is available.)"
|
|
::= { vLANSetting 2 }
|
|
|
|
vSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "LAN Settings for the projector system.( Subnet Mask )
|
|
( To keep setting value in temporary area. When you write the
|
|
vSettingApply, the setting is available.)"
|
|
::= { vLANSetting 3 }
|
|
|
|
vPJSystemName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "LAN Settings for the projector system.( System Name )
|
|
( To keep setting value in temporary area. When you write the
|
|
vSettingApply, the setting is available.)"
|
|
::= { vLANSetting 4 }
|
|
|
|
vGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "LAN Settings for the projector system.( Gateway )
|
|
( To keep setting value in temporary area. When you write the
|
|
vSettingApply, the setting is available.)"
|
|
::= { vLANSetting 5 }
|
|
|
|
vDNS OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "LAN Settings for the projector system.( DNS Configuration )
|
|
( To keep setting value in temporary area. When you write the
|
|
vSettingApply, the setting is available.)"
|
|
::= { vLANSetting 6 }
|
|
|
|
vHostName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..19))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "LAN Settings for the projector system.( Host Name )
|
|
( To keep setting value in temporary area. When you write the
|
|
vSettingApply, the setting is available.)"
|
|
::= { vLANSetting 7 }
|
|
|
|
vDomainName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..59))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "LAN Settings for the projector system.( Domain Name )
|
|
( To keep setting value in temporary area. When you write the
|
|
vSettingApply, the setting is available.)"
|
|
::= { vLANSetting 8 }
|
|
|
|
vSettingApply OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Change settings in vLANSetting.
|
|
(The read value is fixed to 1. )"
|
|
::= { vLANSetting 9 }
|
|
|
|
--<< vSystem.vSystemSetting 2 >>--
|
|
vMailSetting OBJECT IDENTIFIER ::= { vSystemSetting 2 }
|
|
|
|
vAlertMail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(1),
|
|
enable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Mail Settings for the projector system.( Alert Mail )"
|
|
::= { vMailSetting 1 }
|
|
|
|
vSendersAddress OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..60))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Mail Settings for the projector system.( Sender's Address )"
|
|
::= { vMailSetting 2 }
|
|
|
|
vSMTPServer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..60))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Mail Settings for the projector system.( SMTP Server Name )"
|
|
::= { vMailSetting 3 }
|
|
|
|
vRecipientAddress1 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..60))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Mail Settings for the projector system.( Recipient's Address 1 )"
|
|
::= { vMailSetting 4 }
|
|
|
|
vRecipientAddress2 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..60))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Mail Settings for the projector system.( Recipient's Address 2 )"
|
|
::= { vMailSetting 5 }
|
|
|
|
vRecipientAddress3 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..60))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Mail Settings for the projector system.( Recipient's Address 3 )"
|
|
::= { vMailSetting 6 }
|
|
|
|
vTestMail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Execute the Test Mail.
|
|
(The read value is fixed to 1. )"
|
|
::= { vMailSetting 7 }
|
|
|
|
|
|
--<< vSystem.vSystemSetting 3 >>--
|
|
vSNMPSetting OBJECT IDENTIFIER ::= { vSystemSetting 3 }
|
|
|
|
--<< vSystem.vSystemSetting.vSNMPSetting 1 >>--
|
|
vReadSetting OBJECT IDENTIFIER ::= { vSNMPSetting 1 }
|
|
|
|
vReadAcceptAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "SNMP - Read Settings for the projector system.( Accept Address )"
|
|
::= { vReadSetting 1 }
|
|
|
|
vReadAcceptMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "SNMP - Read Settings for the projector system.( Accept Mask )"
|
|
::= { vReadSetting 2 }
|
|
|
|
vReadCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..31))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "SNMP - Read Settings for the projector system.( Community )"
|
|
::= { vReadSetting 3 }
|
|
|
|
--<< vSystem.vSystemSetting.vSNMPSetting 2 >>--
|
|
vWriteSetting OBJECT IDENTIFIER ::= { vSNMPSetting 2 }
|
|
|
|
vWriteAcceptAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "SNMP - Write Settings for the projector system.( Accept Address )"
|
|
::= { vWriteSetting 1 }
|
|
|
|
vWriteAcceptMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "SNMP - Write Settings for the projector system.( Accept Mask )"
|
|
::= { vWriteSetting 2 }
|
|
|
|
vWriteCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..31))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "SNMP - Write Settings for the projector system.( Community )"
|
|
::= { vWriteSetting 3 }
|
|
|
|
--<< vSystem.vSystemSetting.vSNMPSetting 3 >>--
|
|
vTrapSettings OBJECT IDENTIFIER ::= { vSNMPSetting 3 }
|
|
|
|
vTrapSetting OBJECT IDENTIFIER ::= { vTrapSettings 1 }
|
|
|
|
vTrapSettingCount OBJECT-TYPE
|
|
SYNTAX INTEGER(3..3)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "SNMP - Trap Settings for the projector system.( 3 number of settings )
|
|
(fixed number)"
|
|
::= { vTrapSetting 1 }
|
|
|
|
vTrapSettingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TrapSettingTable
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This is a hierarchical tree for the SNMP-Trap setting related to
|
|
the projector system. This object does not have a value."
|
|
::= { vTrapSetting 2 }
|
|
|
|
TrapSettingTable ::= SEQUENCE {
|
|
vTrapSettingIndex INTEGER,
|
|
vTrapSettingIPAddress IpAddress,
|
|
vTrapSettingCommunity DisplayString
|
|
}
|
|
|
|
vTrapSettingEntry OBJECT-TYPE
|
|
SYNTAX TrapSettingTable
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This is a hierarchical tree for the SNMP-Trap setting related to
|
|
the projector system. This object does not have a value."
|
|
INDEX { vTrapSettingIndex }
|
|
::= { vTrapSettingTable 1 }
|
|
|
|
vTrapSettingIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A unique value for each Trap setting. Its value ranges between 1 and
|
|
the value of vTrapSettingCount."
|
|
::= { vTrapSettingEntry 1 }
|
|
|
|
vTrapSettingIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "SNMP - Trap Settings for the projector system.( IP Address )
|
|
If this value is 0.0.0.0, this setting of Trap Setting is invalid."
|
|
::= { vTrapSettingEntry 2 }
|
|
|
|
vTrapSettingCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..31))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "SNMP - Trap Settings for the projector system.( Community )"
|
|
::= { vTrapSettingEntry 3 }
|
|
|
|
vTrapErrorTypeSetting OBJECT IDENTIFIER ::= { vTrapSettings 2 }
|
|
|
|
vTrapErrorTypeEntryCount OBJECT-TYPE
|
|
SYNTAX INTEGER(0..512)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of error definition."
|
|
::= { vTrapErrorTypeSetting 1 }
|
|
|
|
vTrapErrorTypeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TrapErrorTypeTable
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This is a hierarchical tree for the Error Type setting related to
|
|
the projector system. This object does not have a value."
|
|
::= { vTrapErrorTypeSetting 2 }
|
|
|
|
TrapErrorTypeTable ::= SEQUENCE {
|
|
vTrapTypeErrorIndex INTEGER,
|
|
vTrapTypeErrorNumber INTEGER,
|
|
vTrapTypeErrorCaption DisplayString,
|
|
vTrapTypeErrorSetting INTEGER
|
|
}
|
|
|
|
vTrapErrorTypeEntry OBJECT-TYPE
|
|
SYNTAX TrapErrorTypeTable
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This is a hierarchical tree for the Error Type setting related to
|
|
the projector system. This object does not have a value."
|
|
INDEX { vTrapTypeErrorIndex }
|
|
::= { vTrapErrorTypeTable 1 }
|
|
|
|
vTrapTypeErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..512)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A unique value for each Error Type setting. Its value ranges between 1
|
|
and the value of vTrapErrorTypeEntryCount."
|
|
::= { vTrapErrorTypeEntry 1 }
|
|
|
|
vTrapTypeErrorNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(1..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error number."
|
|
::= { vTrapErrorTypeEntry 2 }
|
|
|
|
vTrapTypeErrorCaption OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error caption."
|
|
::= { vTrapErrorTypeEntry 3 }
|
|
|
|
vTrapTypeErrorSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
errorNonCritical(1),
|
|
errorCritical(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The Error Type setting.( Critical / Non-Critical )"
|
|
::= { vTrapErrorTypeEntry 4 }
|
|
|
|
vTrapErrorTypeAllSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
errorNonCritical(1),
|
|
errorCritical(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the Error Type(Critical/Non-Critical) to all itmes.
|
|
(The read value is fixed to 1. )"
|
|
::= { vTrapErrorTypeSetting 3 }
|
|
|
|
vTrapFilteringTrapStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(1),
|
|
enable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The Filtering of vTrapStatus setting."
|
|
::= { vTrapSettings 3 }
|
|
|
|
vTrapFilteringTrapProtect OBJECT IDENTIFIER ::= { vTrapSettings 4 }
|
|
|
|
vTrapProtectFilteringEntryCount OBJECT-TYPE
|
|
SYNTAX INTEGER(0..512)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of error definition."
|
|
::= { vTrapFilteringTrapProtect 1 }
|
|
|
|
vTrapProtectFilteringTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TrapProtectFilteringTable
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This is a hierarchical tree for the filtering setting of vTrapProtect
|
|
related to the projector system. This object does not have a value."
|
|
::= { vTrapFilteringTrapProtect 2 }
|
|
|
|
TrapProtectFilteringTable ::= SEQUENCE {
|
|
vTrapProtectFilteringIndex INTEGER,
|
|
vTrapProtectFilteringErrorNumber INTEGER,
|
|
vTrapProtectFilteringCaption DisplayString,
|
|
vTrapProtectFilteringSetting INTEGER
|
|
}
|
|
|
|
vTrapProtectFilteringEntry OBJECT-TYPE
|
|
SYNTAX TrapProtectFilteringTable
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This is a hierarchical tree for the filtering setting of vTrapProtect
|
|
related to the projector system. This object does not have a value."
|
|
INDEX { vTrapProtectFilteringIndex }
|
|
::= { vTrapProtectFilteringTable 1 }
|
|
|
|
vTrapProtectFilteringIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..512)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A unique value for each filtering setting of vTrapProtect. Its value
|
|
ranges between 1 and the value of vTrapProtectFilteringEntryCount."
|
|
::= { vTrapProtectFilteringEntry 1 }
|
|
|
|
vTrapProtectFilteringErrorNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(1..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error number."
|
|
::= { vTrapProtectFilteringEntry 2 }
|
|
|
|
vTrapProtectFilteringCaption OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The error caption."
|
|
::= { vTrapProtectFilteringEntry 3 }
|
|
|
|
vTrapProtectFilteringSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(1),
|
|
enable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The filtering setting of vTrapProtect."
|
|
::= { vTrapProtectFilteringEntry 4 }
|
|
|
|
vTrapFilteringTrapProtectAllSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(1),
|
|
enable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the Filtering setting of vTrapProtect to all itmes.
|
|
(The read value is fixed to 1. )"
|
|
::= { vTrapFilteringTrapProtect 3 }
|
|
|
|
--<< vSystem 17 >>--
|
|
vSystemFanTargetSpeed OBJECT IDENTIFIER ::= { vSystem 17 }
|
|
|
|
vSystemFTSFan1 OBJECT-TYPE
|
|
SYNTAX INTEGER(-2..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan target speed of Fan1.
|
|
If this value is 0, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)"
|
|
::= { vSystemFanTargetSpeed 1 }
|
|
|
|
vSystemFTSFan2 OBJECT-TYPE
|
|
SYNTAX INTEGER(-2..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan target speed of Fan2.
|
|
If this value is 0, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)"
|
|
::= { vSystemFanTargetSpeed 2 }
|
|
|
|
vSystemFTSFan3 OBJECT-TYPE
|
|
SYNTAX INTEGER(-2..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan target speed of Fan3.
|
|
If this value is 0, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)"
|
|
::= { vSystemFanTargetSpeed 3 }
|
|
|
|
vSystemFTSFan4 OBJECT-TYPE
|
|
SYNTAX INTEGER(-2..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan target speed of Fan4.
|
|
If this value is 0, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)"
|
|
::= { vSystemFanTargetSpeed 4 }
|
|
|
|
vSystemFTSFan5 OBJECT-TYPE
|
|
SYNTAX INTEGER(-2..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan target speed of Fan5.
|
|
If this value is 0, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)"
|
|
::= { vSystemFanTargetSpeed 5 }
|
|
|
|
vSystemFTSFan6 OBJECT-TYPE
|
|
SYNTAX INTEGER(-2..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan target speed of Fan6.
|
|
If this value is 0, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)"
|
|
::= { vSystemFanTargetSpeed 6 }
|
|
|
|
vSystemFTSFan7 OBJECT-TYPE
|
|
SYNTAX INTEGER(-2..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan target speed of Fan7.
|
|
If this value is 0, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)"
|
|
::= { vSystemFanTargetSpeed 7 }
|
|
|
|
vSystemFTSFan8 OBJECT-TYPE
|
|
SYNTAX INTEGER(-2..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan target speed of Fan8.
|
|
If this value is 0, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)"
|
|
::= { vSystemFanTargetSpeed 8 }
|
|
|
|
vSystemFTSFan9 OBJECT-TYPE
|
|
SYNTAX INTEGER(-2..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan target speed of Fan9.
|
|
If this value is 0, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)"
|
|
::= { vSystemFanTargetSpeed 9 }
|
|
|
|
vSystemFTSFan10 OBJECT-TYPE
|
|
SYNTAX INTEGER(-2..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan target speed of Fan10.
|
|
If this value is 0, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)"
|
|
::= { vSystemFanTargetSpeed 10 }
|
|
|
|
vSystemFTSFan11 OBJECT-TYPE
|
|
SYNTAX INTEGER(-2..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan target speed of Fan11.
|
|
If this value is 0, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)"
|
|
::= { vSystemFanTargetSpeed 11 }
|
|
|
|
vSystemFTSFan12 OBJECT-TYPE
|
|
SYNTAX INTEGER(-2..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan target speed of Fan12.
|
|
If this value is 0, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)"
|
|
::= { vSystemFanTargetSpeed 12 }
|
|
|
|
vSystemFTSFan13 OBJECT-TYPE
|
|
SYNTAX INTEGER(-2..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan target speed of Fan13.
|
|
If this value is 0, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)"
|
|
::= { vSystemFanTargetSpeed 13 }
|
|
|
|
vSystemFTSFan14 OBJECT-TYPE
|
|
SYNTAX INTEGER(-2..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan target speed of Fan14.
|
|
If this value is 0, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)"
|
|
::= { vSystemFanTargetSpeed 14 }
|
|
|
|
vSystemFTSFan15 OBJECT-TYPE
|
|
SYNTAX INTEGER(-2..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan target speed of Fan15.
|
|
If this value is 0, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)"
|
|
::= { vSystemFanTargetSpeed 15 }
|
|
|
|
vSystemFTSFan16 OBJECT-TYPE
|
|
SYNTAX INTEGER(-2..99999)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan target speed of Fan16.
|
|
If this value is 0, it means the fan is stopped.
|
|
If this value is -2, it means can not get a fan speed.(error)"
|
|
::= { vSystemFanTargetSpeed 16 }
|
|
|
|
vSystemFTSICPFan OBJECT-TYPE
|
|
SYNTAX INTEGER(0..5500)
|
|
UNITS "rpm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current fan target speed of ICP Fan.
|
|
If this value is 0, it means the fan is stopped."
|
|
::= { vSystemFanTargetSpeed 17 }
|
|
|
|
--
|
|
-- * vLamp **********************************************
|
|
--
|
|
vLampMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
eco(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vLamp 1 }
|
|
|
|
vLampNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vLamp 2 }
|
|
|
|
vLampTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LampEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vLamp 3 }
|
|
|
|
vLampEntry OBJECT-TYPE
|
|
SYNTAX LampEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
INDEX { vLampIndex }
|
|
::= { vLampTable 1 }
|
|
|
|
LampEntry ::= SEQUENCE {
|
|
vLampIndex INTEGER,
|
|
vLampType INTEGER,
|
|
vLampUsage TimeTicks,
|
|
vLampTmWarning TimeTicks,
|
|
vLampTmProtect TimeTicks
|
|
}
|
|
|
|
vLampIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vLampEntry 1 }
|
|
|
|
vLampType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
super-eco(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vLampEntry 2 }
|
|
|
|
vLampUsage OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vLampEntry 3 }
|
|
|
|
vLampTmWarning OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vLampEntry 4 }
|
|
|
|
vLampTmProtect OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vLampEntry 5 }
|
|
|
|
vLampBulbName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..48))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Selected bulb name."
|
|
::= { vLamp 4 }
|
|
|
|
vLampOutput OBJECT IDENTIFIER ::= { vLamp 5 }
|
|
|
|
vLampOutputCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER(0..9999)
|
|
UNITS "x0.1A"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Getting value of output lamp bulb current from LPSU."
|
|
::= { vLampOutput 1 }
|
|
|
|
vLampOutputWattage OBJECT-TYPE
|
|
SYNTAX INTEGER(0..9999)
|
|
UNITS "W"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Getting value of output lamp bulb wattage from LPSU."
|
|
::= { vLampOutput 2 }
|
|
|
|
vLampUsage2 OBJECT IDENTIFIER ::= { vLamp 6 }
|
|
|
|
vLampBulbUsage OBJECT-TYPE
|
|
SYNTAX INTEGER(0..9999)
|
|
UNITS "H"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Lamp bulb usage.(Hour)"
|
|
::= { vLampUsage2 1 }
|
|
|
|
vLamBulbRemain OBJECT-TYPE
|
|
SYNTAX INTEGER(-9999..9999)
|
|
UNITS "H"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Lamp bulb remaining time.(Hour)"
|
|
::= { vLampUsage2 2 }
|
|
|
|
vLampHouseUsage OBJECT-TYPE
|
|
SYNTAX INTEGER(0..9999)
|
|
UNITS "H"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Lamp House usage.(Hour)"
|
|
::= { vLampUsage2 3 }
|
|
|
|
vLampStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unlit(1),
|
|
lit(2),
|
|
litLamp1(3),
|
|
litLamp2(4),
|
|
litLamp1and2(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Lamp status."
|
|
::= { vLamp 7 }
|
|
|
|
vLampOutput2 OBJECT IDENTIFIER ::= { vLamp 8 }
|
|
|
|
vLampOutputWattage2 OBJECT-TYPE
|
|
SYNTAX INTEGER(0..9999)
|
|
UNITS "x0.1W"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Getting value of output lamp wattage."
|
|
::= { vLampOutput2 1 }
|
|
|
|
vLampOutputPer OBJECT-TYPE
|
|
SYNTAX INTEGER(0..9999)
|
|
UNITS "x0.1%"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Getting value of output lamp percent."
|
|
::= { vLampOutput2 2 }
|
|
|
|
vLamp1Voltage OBJECT-TYPE
|
|
SYNTAX INTEGER(0..9999)
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Getting value of output lamp1 voltage."
|
|
::= { vLampOutput2 3 }
|
|
|
|
vLamp2Voltage OBJECT-TYPE
|
|
SYNTAX INTEGER(0..9999)
|
|
UNITS "V"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Getting value of output lamp2 voltage."
|
|
::= { vLampOutput2 4 }
|
|
|
|
vLampUsage3 OBJECT IDENTIFIER ::= { vLamp 9 }
|
|
|
|
vLamp1Usage OBJECT-TYPE
|
|
SYNTAX INTEGER(0..99999)
|
|
UNITS "H"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Lamp1 usage.(Hour)"
|
|
::= { vLampUsage3 1 }
|
|
|
|
vLamp2Usage OBJECT-TYPE
|
|
SYNTAX INTEGER(0..99999)
|
|
UNITS "H"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Lamp2 usage.(Hour)"
|
|
::= { vLampUsage3 2 }
|
|
|
|
vLampWarning OBJECT-TYPE
|
|
SYNTAX INTEGER(0..99999)
|
|
UNITS "H"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Lamp warning time.(Hour)"
|
|
::= { vLampUsage3 3 }
|
|
|
|
vLamp1Remain OBJECT-TYPE
|
|
SYNTAX INTEGER(0..999)
|
|
UNITS "%"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Lamp1 remainig time.(percent)"
|
|
::= { vLampUsage3 4 }
|
|
|
|
vLamp2Remain OBJECT-TYPE
|
|
SYNTAX INTEGER(0..999)
|
|
UNITS "%"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Lamp2 remainig time.(percent)"
|
|
::= { vLampUsage3 5 }
|
|
|
|
vLamp1Strike OBJECT-TYPE
|
|
SYNTAX INTEGER(0..99999)
|
|
UNITS "Times"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Lamp1 strike count.(Times)"
|
|
::= { vLampUsage3 6 }
|
|
|
|
vLamp2Strike OBJECT-TYPE
|
|
SYNTAX INTEGER(0..99999)
|
|
UNITS "Times"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Lamp2 strike count.(Times)"
|
|
::= { vLampUsage3 7 }
|
|
|
|
vLampMode2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dual(1),
|
|
lamp1(2),
|
|
lamp2(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current lamp mode."
|
|
::= { vLamp 10 }
|
|
|
|
|
|
--
|
|
-- * vInput **********************************************
|
|
--
|
|
vInputTerminal OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
computer1(1),
|
|
computer2(2),
|
|
video1(3),
|
|
video2(4),
|
|
svideo1(5),
|
|
svideo2(6),
|
|
rgb1-video(7),
|
|
rgb1-svideo(8),
|
|
component(9),
|
|
dvi-digital(10),
|
|
dvi-analog(11),
|
|
viewer(12),
|
|
lan(13),
|
|
testpattern(14),
|
|
slot1-1(15),
|
|
slot1-2(16),
|
|
slot2-1(17),
|
|
slot2-2(18),
|
|
unknown(19)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vInput 1 }
|
|
|
|
vInputSignal OBJECT IDENTIFIER ::= { vInput 2 }
|
|
|
|
vEntryList OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
default(1),
|
|
user(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vInputSignal 1 }
|
|
|
|
vSignalNo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vInputSignal 2 }
|
|
|
|
vSignalName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vInputSignal 3 }
|
|
|
|
vSignalFormat OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
rgb(1),
|
|
component(2),
|
|
video(3),
|
|
s-video(4),
|
|
scart(5),
|
|
hdtv(6),
|
|
digital(7),
|
|
viewer(8),
|
|
sdi(9)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vInputSignal 4 }
|
|
|
|
vSignalFreqH OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vInputSignal 5 }
|
|
|
|
vSignalFreqV OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vInputSignal 6 }
|
|
|
|
vViewerSlide OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vInputSignal 7 }
|
|
|
|
vViewerTotal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vInputSignal 8 }
|
|
|
|
vActiveTitle OBJECT IDENTIFIER ::= { vInput 3 }
|
|
|
|
vActiveTitleNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of Selected title.
|
|
If this value is 0, it means not to select any titles."
|
|
::= { vActiveTitle 1 }
|
|
|
|
vActiveTitleName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..127))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Name of Selected title.
|
|
If any titles are not selected, returns NULL."
|
|
::= { vActiveTitle 2 }
|
|
|
|
vActivePort OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
portAuto(1),
|
|
port292-A(2),
|
|
port292-B(3),
|
|
port292-Dual-AB(4),
|
|
portReserved1(5),
|
|
portTestPattern(6),
|
|
portDVI-A(7),
|
|
portDVI-B(8),
|
|
portDVI-Dual-Twin(9),
|
|
portReserved2(10),
|
|
portReserved3(11),
|
|
portDVI-Dual-Twin-MMS(12),
|
|
port292-C(13),
|
|
port292-D(14),
|
|
port292-Dual-CD(15),
|
|
port292-Quad(16),
|
|
portIMB(17),
|
|
portUnknown(18)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Active Data Port of the cinema projector."
|
|
::= { vActiveTitle 3 }
|
|
|
|
vActiveSourceType OBJECT-TYPE
|
|
SYNTAX INTEGER(-1..10)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "If active port is 292-A or B or C or D port
|
|
0x00 4:2:2 Unpacked, 10bits/Color (default)
|
|
0x01 4:2:2 Packed, 12bits/Color
|
|
0x02 4:4:4 Packed, 10bits/Color
|
|
0x03 4:4:4 Packed, 12bits/Color
|
|
If active port is 292-Dual(AB or CD),
|
|
0x00 4:2:2 Packed, 10 bits, O/E Pixels (default)
|
|
0x01 4:2:2 Packed, 10 bits, O/E Lines
|
|
0x02 4:2:2 Packed, 12 bits, O/E Pixels
|
|
0x03 4:2:2 Packed, 12 bits, O/E Lines
|
|
0x04 4:4:4 Unpacked, 10 bits
|
|
0x05 4:4:4 Packed, 10 bits, Mixed
|
|
0x06 4:4:4 Packed, 10 bits, O/E Pixels
|
|
0x07 4:4:4 Packed, 12 bits
|
|
0x08 4:2:2 Unpacked, 10 bits, O/E, Frame
|
|
0x09 4:2:2 Unpacked, 10 bits
|
|
0x0A 4:2:2 Packed, 12 bits
|
|
If active port is 292-Quad,
|
|
0x01 4:2:2 Packed, 12 bits, O/E, Frame (default)
|
|
0x02 4:4:4 Unpacked, 10 bits, O/E, Frame
|
|
0x03 4:4:4 Packed, 12 bits, O/E, Frame
|
|
If active port is DVI-A or DVI-B,
|
|
0x00 8 bits/color, Unpacked (default)
|
|
0x01 10 bits/color, Packed
|
|
0x02 12 bits/color, Packed
|
|
0x03 8 bits/color, Unpacked, 3D
|
|
If active port is DVI-Dual/Twin,
|
|
0x03 Twin: 8 bits/color, Unpacked (default)
|
|
0x04 Twin: 10 bits/color, Unpacked
|
|
0x05 Twin: 12 bits/color, Packed
|
|
0x06 Twin: 8 bits/color, Unpacked, 3D
|
|
If active port is IMB,
|
|
0x00 4:4:4 12bit (default)
|
|
0x01 4:2:2 12bit
|
|
|
|
If fails to get this information, return -1."
|
|
::= { vActiveTitle 4 }
|
|
|
|
vActivePCF OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..127))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Active PCF file name."
|
|
::= { vActiveTitle 5 }
|
|
|
|
vActiveSCREEN OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..127))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Active SCREEN file name."
|
|
::= { vActiveTitle 6 }
|
|
|
|
vAspectRatio OBJECT-TYPE
|
|
SYNTAX INTEGER (-1..8000)
|
|
UNITS "x0.001"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current aspect ratio.
|
|
If fails to get this information, return -1."
|
|
::= { vActiveTitle 7 }
|
|
|
|
vSubTitleStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current subtitle function setting."
|
|
::= { vActiveTitle 8 }
|
|
|
|
vActiveDataType OBJECT-TYPE
|
|
SYNTAX INTEGER (-1..4)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current Data Type.
|
|
0x00 Progressive
|
|
0x01 Field Interlaced (Field Bit Normal)
|
|
0x02 Field Interlaced (Field Bit Inverted)
|
|
0x03 PsF (1st Field Dominant)
|
|
0x04 PsF (2nd Field Dominant)
|
|
|
|
If fails to get this information, return -1."
|
|
::= { vActiveTitle 9 }
|
|
|
|
vActive3D OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..127))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Active 3D file name."
|
|
::= { vActiveTitle 10 }
|
|
|
|
|
|
vTestPattern OBJECT IDENTIFIER ::= { vInput 4 }
|
|
|
|
vTestPatternStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current testpattern setting."
|
|
::= { vTestPattern 1 }
|
|
|
|
vTestPatternFileName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..127))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Selected testpattern file name."
|
|
::= { vTestPattern 2 }
|
|
|
|
|
|
--
|
|
-- * vOutput **********************************************
|
|
--
|
|
vVolume OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vOutput 1 }
|
|
|
|
vFreeze OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
freezeOff(1),
|
|
freezeOn(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vOutput 2 }
|
|
|
|
vMagnify OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vOutput 3 }
|
|
|
|
vMute OBJECT IDENTIFIER ::= { vOutput 4 }
|
|
|
|
vMutePicture OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
muteOff(1),
|
|
muteOn(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vMute 1 }
|
|
|
|
vMuteSound OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
muteOff(1),
|
|
muteOn(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vMute 2 }
|
|
|
|
vMuteOSD OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
muteOff(1),
|
|
muteOn(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vMute 3 }
|
|
|
|
vPicture OBJECT IDENTIFIER ::= { vOutput 5 }
|
|
|
|
vBrightness OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vPicture 1 }
|
|
|
|
vContrast OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vPicture 2 }
|
|
|
|
vColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vPicture 3 }
|
|
|
|
vHue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vPicture 4 }
|
|
|
|
vSharpness OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vPicture 5 }
|
|
|
|
vKeystoneH OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vPicture 6 }
|
|
|
|
vKeystoneV OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vPicture 7 }
|
|
|
|
--
|
|
-- * vSetting **********************************************
|
|
--
|
|
vLanguage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lEnglish(1),
|
|
lJapanese(2),
|
|
lGerman(3),
|
|
lFrench(4),
|
|
lItalian(5),
|
|
lSpanish(6),
|
|
lSwedish(7),
|
|
lChinese(8),
|
|
lFinnish(9),
|
|
lNorwegian(10),
|
|
lDutch(11),
|
|
lTurkish(12),
|
|
lPolish(13),
|
|
lRussian(14),
|
|
lGreek(15),
|
|
lKorean(16),
|
|
lHungarian(17),
|
|
lPortuguese(18),
|
|
lOthers(19)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vSetting 1 }
|
|
|
|
vOrientation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
desktop-front(1),
|
|
ceiling-rear(2),
|
|
desktop-rear(3),
|
|
ceiling-front(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vSetting 2 }
|
|
|
|
vBackground OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blue(1),
|
|
black(2),
|
|
logo(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION ""
|
|
::= { vSetting 3 }
|
|
|
|
|
|
--
|
|
-- * vTraps **********************************************
|
|
--
|
|
vTrapStatus NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vStatus,
|
|
vSystemDouser,
|
|
vActiveTitleNumber,
|
|
vTestPatternStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "This trap is sent, when the following status are changed.
|
|
vStatus
|
|
vSystemDouser
|
|
vActiveTitleNumber
|
|
vTestPatternStatus"
|
|
::= { vTraps 1 }
|
|
|
|
vTrapProtect NOTIFICATION-TYPE
|
|
OBJECTS { vSystemErrorCriticalCounts }
|
|
STATUS current
|
|
DESCRIPTION "This trap is sent, when the new critical error is occurred."
|
|
::= { vTraps 2 }
|
|
|
|
vTrapProtectNC NOTIFICATION-TYPE
|
|
OBJECTS { vSystemErrorNonCriticalCounts }
|
|
STATUS current
|
|
DESCRIPTION "This trap is sent, when the new error of Non-Critical is occurred."
|
|
::= { vTraps 3 }
|
|
|
|
vTrapProtectStr NOTIFICATION-TYPE
|
|
OBJECTS { vSystemErrorInformation }
|
|
STATUS current
|
|
DESCRIPTION "This trap is sent, when the new critical error is occurred."
|
|
::= { vTraps 4 }
|
|
|
|
vTrapProtectStrNC NOTIFICATION-TYPE
|
|
OBJECTS { vSystemErrorInformation }
|
|
STATUS current
|
|
DESCRIPTION "This trap is sent, when the new error of Non-Critical is occurred."
|
|
::= { vTraps 5 }
|
|
|
|
|
|
END
|