Files
smarttms-rpm-build/rpmbuild/BUILD/smarttms-1.0/apache-tomcat-7.0.63/BS_mibs/VIEWLIGHT-MIB.mib
2025-12-05 21:28:39 +08:00

4576 lines
134 KiB
Plaintext
Executable File

--
-- VIEWLIGHT-MIB
--
-- VIEWLIGHT-MIB created 12/20/2011 as Version 1.06 for
-- the digital cinema projector by NEC Display Solutions, Ltd.
VIEWLIGHT-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
TimeTicks, Counter32, enterprises
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC;
nec OBJECT IDENTIFIER ::= { enterprises 119 }
necProduct OBJECT IDENTIFIER ::= { nec 1 }
nec-mib OBJECT IDENTIFIER ::= { nec 2 }
necProductDepend OBJECT IDENTIFIER ::= { nec-mib 3 }
-- necExperimental OBJECT IDENTIFIER ::= { nec 3 }
-- necProductEx OBJECT IDENTIFIER ::= { necExperimental 2 }
--
-- ViewLight Private MIB
--
viewlight OBJECT IDENTIFIER ::= { necProduct 123 }
viewlight-mib OBJECT IDENTIFIER ::= { necProductDepend 123 }
-- viewlight-ex OBJECT IDENTIFIER ::= { necProductEx 123 }
vTraps OBJECT IDENTIFIER ::= { viewlight-mib 0 }
vSystem OBJECT IDENTIFIER ::= { viewlight-mib 1 }
vLamp OBJECT IDENTIFIER ::= { viewlight-mib 2 }
vInput OBJECT IDENTIFIER ::= { viewlight-mib 3 }
vOutput OBJECT IDENTIFIER ::= { viewlight-mib 4 }
vSetting OBJECT IDENTIFIER ::= { viewlight-mib 5 }
--
-- * vSystem **********************************************
--
--<< vSystem 1 >>--
vSystemName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the name that is set in the projector."
::= { vSystem 1 }
--<< vSystem 2 >>--
vVersion OBJECT IDENTIFIER ::= { vSystem 2 }
vVerBIOS OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the BIOS version number of System for
the projector."
::= { vVersion 1 }
vVerFirm OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the firmware version number of System
for the projector."
::= { vVersion 2 }
vVerData OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the data version number of System for
the projector."
::= { vVersion 3 }
--<< vSystem 3 >>--
vStatus OBJECT-TYPE
SYNTAX INTEGER {
powerOff(1),
powerOn(2),
cooling(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the power supply status of the projector."
::= { vSystem 3 }
--<< vSystem 4 >>--
vAlert OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vSystem 4 }
--<< vSystem 5 >>--
vSystemTime OBJECT IDENTIFIER ::= { vSystem 5 }
vSystemTmProjector OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the total usage time of the projector.
(System Usage)"
::= { vSystemTime 1 }
vSystemTmFilter OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vSystemTime 2 }
vSystemTmFilterLamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the total usage time of the lamp filter."
::= { vSystemTime 3 }
vSystemTmFilterBody OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the total usage time of the body filter."
::= { vSystemTime 4 }
vSystemTmFanACOn OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the total usage time of the fan during ac on.
(AC On Fan Usage)"
::= { vSystemTime 5 }
vSystemTmFanPowerOn OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the total usage time of the fan during power on.
(Power On Fan Usage)"
::= { vSystemTime 6 }
vSystemTmFanLamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the total usage time of the fan during lamp on.
(Lamp Fan Usage)"
::= { vSystemTime 7 }
vSystemDouserCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The counts of douser(open/close)."
::= { vSystemTime 8 }
vSystemTmFilterUsage OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the total usage time of the filter."
::= { vSystemTime 9 }
vSystemTmFanUsage OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the total usage time of the fan during power on."
::= { vSystemTime 10 }
--<< vSystem 6 >>--
vSystemDouser OBJECT-TYPE
SYNTAX INTEGER {
open(1),
close(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Douser mode setting."
::= { vSystem 6 }
--<< vSystem 7 >>--
vSystemTemperature OBJECT IDENTIFIER ::= { vSystem 7 }
vSystemCinemaTemp OBJECT-TYPE
SYNTAX INTEGER(-1270..1270)
UNITS "x0.1'C"
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "Ambient temperature on the Cinema board in degrees C."
::= { vSystemTemperature 1 }
vSystemChestTemp OBJECT-TYPE
SYNTAX INTEGER(-1270..1270)
UNITS "x0.1'C"
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "Temperature on the Cinema board chest in degrees C."
::= { vSystemTemperature 2 }
vSystemDMDTemp OBJECT-TYPE
SYNTAX INTEGER(-1270..1270)
UNITS "x0.1'C"
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "Temperature on the DMD in degrees C."
::= { vSystemTemperature 3 }
vSystemOutsideAirTemp OBJECT-TYPE
SYNTAX INTEGER(-1270..1270)
UNITS "x0.1'C"
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "Temperature in the outside air in degrees C."
::= { vSystemTemperature 4 }
vSystemInsideAirTemp OBJECT-TYPE
SYNTAX INTEGER(-1270..1270)
UNITS "x0.1'C"
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "Temperature in the inside air in degrees C."
::= { vSystemTemperature 5 }
vSystemRearsideAirTemp OBJECT-TYPE
SYNTAX INTEGER(-1270..1270)
UNITS "x0.1'C"
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "Temperature in the rearside air in degrees C."
::= { vSystemTemperature 6 }
vSystemCinemaMAX6656Temp OBJECT-TYPE
SYNTAX INTEGER(0..1270)
UNITS "x0.1'C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Temperature of MAX6656 on the ICP board in degrees C."
::= { vSystemTemperature 7 }
vSystemCinemaICPFPGATemp OBJECT-TYPE
SYNTAX INTEGER(0..1270)
UNITS "x0.1'C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Temperature of ICP FPGA on the ICP board in degrees C."
::= { vSystemTemperature 8 }
vSystemCinemaFMTFPGATemp OBJECT-TYPE
SYNTAX INTEGER(0..1270)
UNITS "x0.1'C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Temperature of FMT FPGA on the ICP board in degrees C."
::= { vSystemTemperature 9 }
vSystemS2OutsideAirTemp OBJECT-TYPE
SYNTAX INTEGER(-1270..1270)
UNITS "x0.1'C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Temperature in the outside air in degrees C."
::= { vSystemTemperature 10 }
vSystemS2LPSUIntakeTemp OBJECT-TYPE
SYNTAX INTEGER(-1270..1270)
UNITS "x0.1'C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Temperature in the LPSU Intake in degrees C."
::= { vSystemTemperature 11 }
vSystemS2ExhaustTemp OBJECT-TYPE
SYNTAX INTEGER(-1270..1270)
UNITS "x0.1'C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Temperature in the Exhaust in degrees C."
::= { vSystemTemperature 12 }
vSystemS2DMDBTemp OBJECT-TYPE
SYNTAX INTEGER(-1270..1270)
UNITS "x0.1'C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Temperature on the DMD-B in degrees C."
::= { vSystemTemperature 13 }
vSystemYsTempDMD OBJECT-TYPE
SYNTAX INTEGER(-200..1000)
UNITS "x0.1'C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Temperature on the DMD in degrees C."
::= { vSystemTemperature 14 }
vSystemYsTempInlet OBJECT-TYPE
SYNTAX INTEGER(-200..1000)
UNITS "x0.1'C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Temperature on the Inlet in degrees C."
::= { vSystemTemperature 15 }
vSystemYsTempBallast1 OBJECT-TYPE
SYNTAX INTEGER(-200..1000)
UNITS "x0.1'C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Temperature on the Ballast1 in degrees C."
::= { vSystemTemperature 16 }
vSystemYsTempBallast2 OBJECT-TYPE
SYNTAX INTEGER(-200..1000)
UNITS "x0.1'C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Temperature on the Ballast2 in degrees C."
::= { vSystemTemperature 17 }
--<< vSystem 8 >>--
vSystemError OBJECT IDENTIFIER ::= { vSystem 8 }
vSystemErrorCounts OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of current occurring errors."
::= { vSystemError 1 }
vSystemErrorTable OBJECT-TYPE
SYNTAX SEQUENCE OF SystemErrorInfo
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This is a hierarchical tree for the error
information related to the projector system.
This object does not have a value."
::= { vSystemError 2 }
SystemErrorInfo ::= SEQUENCE {
vSystemErrorIndex INTEGER,
vSystemErrorInformation DisplayString (SIZE(0..63))
}
vSystemErrorEntry OBJECT-TYPE
SYNTAX SystemErrorInfo
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This is a hierarchical tree for the error
information related to the projector system.
This object does not have a value."
INDEX { vSystemErrorIndex }
::= { vSystemErrorTable 1 }
vSystemErrorIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "These are the characteristic numbers that are
assigned to the various errors.
The x within the OID can be any integer value
from 1 to vSystemErrorCounts."
::= { vSystemErrorEntry 1 }
vSystemErrorInformation OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the error information.
The x within the OID can be any integer value
from 1 to vSystemErrorCounts.
Format : `YYYY/MM/DD HH:MM:SS(n) sss' + NULL
YYYY : Year
MM : Month
DD : Date
HH : Hour
MM : Minute
SS : Second
n : number of error
sss : error message"
::= { vSystemErrorEntry 2 }
vSystemErrorCriticalCounts OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of current occurring errors.(Critical Error)"
::= { vSystemError 3 }
vSystemErrorNonCriticalCounts OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of current occurring errors.(Non-Critical Error)"
::= { vSystemError 4 }
vSystemErrorCriticalNewCounts OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of new occurring errors since last trap issued.
(Critical Error)"
::= { vSystemError 5 }
vSystemErrorCriticalTrapNewErrorTable OBJECT-TYPE
SYNTAX SEQUENCE OF CriticalTrapNewError
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This is a hierarchical tree for the new occurred error table.
( Critical-Error )
This object does not have a value."
::= { vSystemError 6 }
CriticalTrapNewError ::= SEQUENCE {
vSystemErrorCriticalTrapNewErrorIndex INTEGER,
vSystemErrorCriticalTrapNewErrorNumber INTEGER
}
vSystemErrorCriticalTrapNewError OBJECT-TYPE
SYNTAX CriticalTrapNewError
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This is a hierarchical tree for the new occurred error table.
( Critical-Error )
This object does not have a value."
INDEX { vSystemErrorCriticalTrapNewErrorIndex }
::= { vSystemErrorCriticalTrapNewErrorTable 1 }
vSystemErrorCriticalTrapNewErrorIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "These are the characteristic numbers that are
assigned to the various errors.
The x within the OID can be any integer value
from 1 to vSystemErrorCriticalNewCounts."
::= { vSystemErrorCriticalTrapNewError 1 }
vSystemErrorCriticalTrapNewErrorNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the new occurred error number.
( Critical-Error )"
::= { vSystemErrorCriticalTrapNewError 2 }
vSystemErrorNonCriticalNewCounts OBJECT-TYPE
SYNTAX INTEGER(0..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of new occurring errors since last trap issued.
(Non-Critical Error)"
::= { vSystemError 7 }
vSystemErrorNonCriticalTrapNewErrorTable OBJECT-TYPE
SYNTAX SEQUENCE OF NonCriticalTrapNewError
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This is a hierarchical tree for the new occurred error table.
( Non-Critical-Error )
This object does not have a value."
::= { vSystemError 8 }
NonCriticalTrapNewError ::= SEQUENCE {
vSystemErrorNonCriticalTrapNewErrorIndex INTEGER,
vSystemErrorNonCriticalTrapNewErrorNumber INTEGER
}
vSystemErrorNonCriticalTrapNewError OBJECT-TYPE
SYNTAX NonCriticalTrapNewError
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This is a hierarchical tree for the new occurred error table.
( Non-Critical-Error )
This object does not have a value."
INDEX { vSystemErrorNonCriticalTrapNewErrorIndex }
::= { vSystemErrorNonCriticalTrapNewErrorTable 1 }
vSystemErrorNonCriticalTrapNewErrorIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "These are the characteristic numbers that are
assigned to the various errors.
The x within the OID can be any integer value
from 1 to vSystemErrorNonCriticalNewCounts."
::= { vSystemErrorNonCriticalTrapNewError 1 }
vSystemErrorNonCriticalTrapNewErrorNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the new occurred error number.
( Non-Critical-Error )"
::= { vSystemErrorNonCriticalTrapNewError 2 }
vSystemErrorInDirectNumber OBJECT-TYPE
SYNTAX SEQUENCE OF InDirectNumber
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This is a hierarchical tree for the system error in Direct number.
This object does not have a value."
::= { vSystemError 9 }
InDirectNumber ::= SEQUENCE {
vErrLampDoorOpen INTEGER,
vErrLampOverTemp INTEGER,
vErrGPSU12VFail INTEGER,
vErrLampUnlit INTEGER,
vErrHouseOverTime INTEGER,
vErrLPSUOverTemp INTEGER,
vErrE2PROMRFail INTEGER,
vErrInterlockFail INTEGER,
vErrE2PROMWFail INTEGER,
vErrPumpStop INTEGER,
vErrDLPAckFail INTEGER,
vErrLensFail INTEGER,
vErrBulbOverTime INTEGER,
vErrLPSUFail INTEGER,
vErrOutRange INTEGER,
vErrDownLampPower INTEGER,
vErrMMSCommFail INTEGER,
vErrMMSFanStop INTEGER,
vErrMMSFail INTEGER,
vErrMMReset INTEGER,
vErrDLPCommRFail INTEGER,
vErrDLPCommEFail INTEGER,
vErrSensorFailOutsideAir INTEGER,
vErrSensorFailLPSUIntake INTEGER,
vErrSensorFailExhaust INTEGER,
vErrSensorFailDMDB INTEGER,
vErrFan0Stop INTEGER,
vErrFan1Stop INTEGER,
vErrFan2Stop INTEGER,
vErrFan3Stop INTEGER,
vErrFan4Stop INTEGER,
vErrFan5Stop INTEGER,
vErrFan6Stop INTEGER,
vErrFan7Stop INTEGER,
vErrFan8Stop INTEGER,
vErrFan9Stop INTEGER,
vErrGPSUFanStop INTEGER,
vErrLampFan0Stop INTEGER,
vErrLampFan1Stop INTEGER,
vErrICPFanStop INTEGER,
vErrGPIMACRO INTEGER,
vErrGPIControl INTEGER,
vErrOverTempOutsideAir INTEGER,
vErrOverTempPrecaution INTEGER,
vErrOverTempExhaust INTEGER,
vErrOverTempDMDB INTEGER,
vErrBulbEntry INTEGER,
vErrTamperFail INTEGER,
vErrMarriageTamperFail INTEGER,
vErrCPUFail INTEGER,
vErrGPSU24VFail INTEGER,
vErrLogWriteFail INTEGER,
vErrUnknownLPSUModel INTEGER,
vErrLPSUFanStop INTEGER,
vErr12VOutsiderange INTEGER,
vErr24VOutsiderange INTEGER,
vErrFilterTimeOver INTEGER,
vErrBodyFilterTimeOver INTEGER,
vErrFanExchangeTime INTEGER,
vErrPowerOnFanExchangeTime INTEGER,
vErrLampFanExchangeTime INTEGER,
vErrRouterFail INTEGER,
vErrSensorFailOpt INTEGER,
vErrMACWriteFail INTEGER,
vErrIllegalMACAddress INTEGER,
vErrRouterSelfCheckFail INTEGER,
vErrRouterFirmwareUpdateFail INTEGER,
vErrSIBCommFail INTEGER,
vErrSIBError INTEGER,
vErrSIBFPGAReboot INTEGER,
vErrFan10Stop INTEGER,
vErrFan11Stop INTEGER,
vErrFan12Stop INTEGER,
vErrFan13Stop INTEGER,
vErrFan14Stop INTEGER,
vErrFan0StopPrecaution INTEGER,
vErrFan1StopPrecaution INTEGER,
vErrFan2StopPrecaution INTEGER,
vErrFan3StopPrecaution INTEGER,
vErrFan4StopPrecaution INTEGER,
vErrFan5StopPrecaution INTEGER,
vErrFan6StopPrecaution INTEGER,
vErrFan7StopPrecaution INTEGER,
vErrFan8StopPrecaution INTEGER,
vErrFan9StopPrecaution INTEGER,
vErrLampFan0StopPrecaution INTEGER,
vErrLampFan1StopPrecaution INTEGER,
vErrPumpStopPrecaution INTEGER,
vErrICPFanStopPrecaution INTEGER,
vErrFan10StopPrecaution INTEGER,
vErrFan11StopPrecaution INTEGER,
vErrFan12StopPrecaution INTEGER,
vErrFan13StopPrecaution INTEGER,
vErrFan14StopPrecaution INTEGER,
vErrSDTamperTerminate INTEGER,
vErrIMBSDTamperTerminate INTEGER,
vErrBulbWarrantyOver INTEGER,
vErrSystemError INTEGER,
vErrSelfTestError INTEGER,
vErrInstallReleasePackage INTEGER,
vErrLoadReleasePackage INTEGER,
vErrKeyError INTEGER,
vErrCertificateError INTEGER,
vErrICPNormalConfiguration INTEGER,
vErrICPBootConfiguration INTEGER,
vErrFMTNormalConfiguration INTEGER,
vErrFMTBootConfiguration INTEGER,
vErrFMTSatelliteConfiguration INTEGER,
vErr120VSupplyoutofrange INTEGER,
vErr180VSupplyoutofrange INTEGER,
vErr250VSupplyoutofrange INTEGER,
vErr330VRegulatoroutofrange INTEGER,
vErrICPFPGATemperatureoutofrange INTEGER,
vErrFMTFPGATemperatureoutofrange INTEGER,
vErrICPFlashUpdate INTEGER,
vErrFMTSequenceDataFileMismatch INTEGER,
vErrFMTDMDDataFileMismatch INTEGER,
vErrFMTFlashChecksumSequenceData INTEGER,
vErrFMTFlashChecksumDMDData INTEGER,
vErrSatelliteHardwareMismatch INTEGER,
vErrFMTFlashUpdate INTEGER,
vErrRedSatelliteReportsReset INTEGER,
vErrRedSatelliteSerialLink INTEGER,
vErrRedSatelliteFirmwareConfiguration INTEGER,
vErrRedDAD1000BiasUnderVoltage INTEGER,
vErrRedDAD1000ResetUnderVoltage INTEGER,
vErrRedDAD1000OffsetUnderVoltage INTEGER,
vErrRedDAD1000ThermalShutdown INTEGER,
vErrGreenSatelliteReportsReset INTEGER,
vErrGreenSatelliteSerialLink INTEGER,
vErrGreenSatelliteFirmwareConfiguration INTEGER,
vErrGreenDAD1000BiasUnderVoltage INTEGER,
vErrGreenDAD1000ResetUnderVoltage INTEGER,
vErrGreenDAD1000OffsetUnderVoltage INTEGER,
vErrGreenDAD1000ThermalShutdown INTEGER,
vErrBlueSatelliteReportsReset INTEGER,
vErrBlueSatelliteSerialLink INTEGER,
vErrBlueSatelliteFirmwareConfiguration INTEGER,
vErrBlueDAD1000BiasUnderVoltage INTEGER,
vErrBlueDAD1000ResetUnderVoltage INTEGER,
vErrBlueDAD1000OffsetUnderVoltage INTEGER,
vErrBlueDAD1000ThermalShutdown INTEGER,
vErrRTCError INTEGER,
vErrICPFrameMemoryTestResult INTEGER,
vErrICPDataPathSignatureTestResult INTEGER,
vErrEnigmaCommFail INTEGER,
vErrEnigmaSystemError INTEGER,
vErrEnigmaSelfTestError INTEGER,
vErrEnigmaInstallReleasePackage INTEGER,
vErrEnigmaLoadReleasePackage INTEGER,
vErrEnigmaTILoginListPackage INTEGER,
vErrEnigmaSecurityOfficerLoginListPackage INTEGER,
vErrEnigmaCertificateorKey INTEGER,
vErrEnigmaICPCommunicationsStatus INTEGER,
vErrEnigmaUserLoaderIntegrity INTEGER,
vErrEnigmaMainApplicationIntegrity INTEGER,
vErrEnigmaRNGHardwareIntegrity INTEGER,
vErrEnigmaDRNGAlgorithmIntegrity INTEGER,
vErrEnigmaRSAAlgorithmIntegrity INTEGER,
vErrEnigmaAESAlgorithmIntegrity INTEGER,
vErrEnigmaHMACAlgorithmIntegrity INTEGER,
vErrEnigmaSHAAlgorithmIntegrity INTEGER,
vErrEnigmaTLSIntegrity INTEGER,
vErrEnigmaFPGAConfigurationIntegrity INTEGER,
vErrEnigmaFPGACineLink2 INTEGER,
vErrEnigmaRTCError INTEGER,
vErrEnigmaFPGAConfiguration INTEGER,
vErrEnigmaFPGATemperatureoutofrange INTEGER,
vErrEnigmaRNGHardwareDuplicateOutput INTEGER,
vErrEnigmaDRNGAlgorithmDuplicateOutput INTEGER,
vErrEnigma120VSupplyoutofrange INTEGER,
vErrEnigma180VSupplyoutofrange INTEGER,
vErrEnigma250VSupplyoutofrange INTEGER,
vErrEnigma330VRegulatoroutofrange INTEGER,
vErrEnigmaSelfTestUserLoader INTEGER,
vErrEnigmaSelfTestMainApplication INTEGER,
vErrEnigmaSelfTestRNGHardware INTEGER,
vErrEnigmaSelfTestDRNGAlgorithm INTEGER,
vErrEnigmaSelfTestRSAAlgorithm INTEGER,
vErrEnigmaSelfTestAESAlgorithm INTEGER,
vErrEnigmaSelfTestHMACAlgorithm INTEGER,
vErrEnigmaSelfTestSHAAlgorithm INTEGER,
vErrEnigmaSelfTestTLSIntegrity INTEGER,
vErrEnigmaSelfTestFPGAConfiguration INTEGER,
vErrEnigmaSelfTestFPGACineLink2 INTEGER,
vErrEnigmaSecurityTamper INTEGER,
vErrEnigmaTopSideSecurityEnclosureOpen INTEGER,
vErrEnigmaBottomSideSecurityEnclosureOpen INTEGER,
vErrEnigmaSecurityBatteryEvent INTEGER,
vErrEnigmaSoftwareCommandedZeroization INTEGER,
vErrEnigmaSecurityEnclosureNotArmed INTEGER,
vErrEnigmaPhysicalMarriageTamper INTEGER,
vErrEnigmaLogicalMarriageTamper INTEGER,
vErrEnigmaMarriageNOTActive INTEGER,
vErrEnigmaServiceDoorTamper INTEGER,
vErrEnigmaSecurityLog INTEGER,
vErrEnigmaSecurityBatteryLowWarning INTEGER,
vErrEnigmaSecurityLogWarning INTEGER,
vErrIMBCommFail INTEGER,
vErrIMBSystemError INTEGER,
vErrIMBSelfTestError INTEGER,
vErrIMBCertificateorKey INTEGER,
vErrIMBICPCommunicationsStatus INTEGER,
vErrIMBRTCError INTEGER,
vErrIMBFPGATemperatureoutofrange INTEGER,
vErrIMBSupplyvoltageoutofrange INTEGER,
vErrIMBSecurityTamper INTEGER,
vErrIMBSecurityBatteryEvent INTEGER,
vErrIMBSecurityEnclosureNotArmed INTEGER,
vErrIMBPhysicalMarriageTamper INTEGER,
vErrIMBLogicalMarriageTamper INTEGER,
vErrIMBMarriageNOTActive INTEGER,
vErrIMBServiceDoorTamper INTEGER,
vErrIMBSecurityBatteryLowWarning INTEGER,
vErrSlaveCommFail INTEGER,
vErrSlaveStatusFail INTEGER,
vErrLampLitChange INTEGER,
vErrSlaveCommAckFail INTEGER,
vErrLamp1OverTime INTEGER,
vErrLamp2OverTime INTEGER,
vErrSensorFailInlet INTEGER,
vErrSensorFailDMD INTEGER,
vErrOverTempDMDPrecaution INTEGER,
vErrOverTempInletPrecaution INTEGER,
vErrDownLampPowerActivated INTEGER,
vErrOverTempBallast1Precaution INTEGER,
vErrOverTempBallast2Precaution INTEGER,
vErrOverTempDMD INTEGER,
vErrOverTempInlet INTEGER,
vErrOverTempLamp INTEGER,
vErrOverTempBallast1 INTEGER,
vErrOverTempBallast2 INTEGER,
vErrInterlockOpen INTEGER,
vErrSystemI2cFail INTEGER,
vErrEepromFail INTEGER,
vErrEepVersionFail INTEGER,
vErrSoftwareI2cFail INTEGER,
vErrPreCooling INTEGER,
vErrLamp1DoorOpen INTEGER,
vErrLamp2DoorOpen INTEGER,
vErrBallast1Uart INTEGER,
vErrBallast2Uart INTEGER,
vErrFanInit INTEGER,
vErrExGpioFail INTEGER,
vErrNotchFilterOpen INTEGER,
vErrFan15Stop INTEGER,
vErrFan16Stop INTEGER,
vErrFan15StopPrecaution INTEGER,
vErrFan16StopPrecaution INTEGER
}
NCs2ErrorType ::= INTEGER { good(1), bad(2) }
vErrLampDoorOpen
OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(1) Lamp Door Open"
::= { vSystemErrorInDirectNumber 1
}
vErrLampOverTemp OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(2) Lamp OverTemp."
::= { vSystemErrorInDirectNumber 2 }
vErrGPSU12VFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(4) GPSU (12V) Fail"
::= { vSystemErrorInDirectNumber 4 }
vErrLampUnlit OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(5) Lamp Unlit"
::= { vSystemErrorInDirectNumber 5 }
vErrHouseOverTime OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(6) House OverTime"
::= { vSystemErrorInDirectNumber 6 }
vErrLPSUOverTemp OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(8) LPSU OverTemp."
::= { vSystemErrorInDirectNumber 8 }
vErrE2PROMRFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(12) E2PROM R Fail"
::= { vSystemErrorInDirectNumber 12 }
vErrInterlockFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(13) Interlock Fail"
::= { vSystemErrorInDirectNumber 13 }
vErrE2PROMWFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(15) E2PROM W Fail"
::= { vSystemErrorInDirectNumber 15 }
vErrPumpStop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(17) Pump Stop"
::= { vSystemErrorInDirectNumber 17 }
vErrDLPAckFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(120) DLP Ack Fail"
::= { vSystemErrorInDirectNumber 120 }
vErrLensFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(121) Lens Fail"
::= { vSystemErrorInDirectNumber 121 }
vErrBulbOverTime OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(123) Bulb OverTime"
::= { vSystemErrorInDirectNumber 123 }
vErrLPSUFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(125) LPSU Fail"
::= { vSystemErrorInDirectNumber 125 }
vErrOutRange OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(128) OutRange"
::= { vSystemErrorInDirectNumber 128 }
vErrDownLampPower OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(129) Down Lamp Power"
::= { vSystemErrorInDirectNumber 129 }
vErrMMSCommFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(130) MMS Comm Fail"
::= { vSystemErrorInDirectNumber 130 }
vErrMMSFanStop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(131) MMS Fan Stop"
::= { vSystemErrorInDirectNumber 131 }
vErrMMSFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(132) MMS Fail"
::= { vSystemErrorInDirectNumber 132 }
vErrMMReset OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(133) MM Reset"
::= { vSystemErrorInDirectNumber 133 }
vErrDLPCommRFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(140) DLP CommR Fail"
::= { vSystemErrorInDirectNumber 140 }
vErrDLPCommEFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(141) DLP CommE Fail"
::= { vSystemErrorInDirectNumber 141 }
vErrSensorFailOutsideAir OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(145) SensorFail Outside Air"
::= { vSystemErrorInDirectNumber 145 }
vErrSensorFailLPSUIntake OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(146) SensorFail LPSU Intake"
::= { vSystemErrorInDirectNumber 146 }
vErrSensorFailExhaust OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(147) SensorFail Exhaust"
::= { vSystemErrorInDirectNumber 147 }
vErrSensorFailDMDB OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(148) SensorFail DMD-B"
::= { vSystemErrorInDirectNumber 148 }
vErrFan0Stop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(150) Fan0 Stop"
::= { vSystemErrorInDirectNumber 150 }
vErrFan1Stop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(151) Fan1 Stop"
::= { vSystemErrorInDirectNumber 151 }
vErrFan2Stop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(152) Fan2 Stop"
::= { vSystemErrorInDirectNumber 152 }
vErrFan3Stop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(153) Fan3 Stop"
::= { vSystemErrorInDirectNumber 153 }
vErrFan4Stop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(154) Fan4 Stop"
::= { vSystemErrorInDirectNumber 154 }
vErrFan5Stop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(155) Fan5 Stop"
::= { vSystemErrorInDirectNumber 155 }
vErrFan6Stop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(156) Fan6 Stop"
::= { vSystemErrorInDirectNumber 156 }
vErrFan7Stop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(157) Fan7 Stop"
::= { vSystemErrorInDirectNumber 157 }
vErrFan8Stop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(158) Fan8 Stop"
::= { vSystemErrorInDirectNumber 158 }
vErrFan9Stop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(159) Fan9 Stop"
::= { vSystemErrorInDirectNumber 159 }
vErrGPSUFanStop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(160) GPSU Fan Stop"
::= { vSystemErrorInDirectNumber 160 }
vErrLampFan0Stop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(162) Lamp Fan0 Stop"
::= { vSystemErrorInDirectNumber 162 }
vErrLampFan1Stop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(163) Lamp Fan1 Stop"
::= { vSystemErrorInDirectNumber 163 }
vErrICPFanStop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(164) ICP Fan Stop"
::= { vSystemErrorInDirectNumber 164 }
vErrGPIMACRO OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(165) GPI MACRO Selection Invalid"
::= { vSystemErrorInDirectNumber 165 }
vErrGPIControl OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(166) GPI Control Invalid"
::= { vSystemErrorInDirectNumber 166 }
vErrOverTempOutsideAir OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(170) OverTemp.Outside Air"
::= { vSystemErrorInDirectNumber 170 }
vErrOverTempPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(171) OverTemp Precaution"
::= { vSystemErrorInDirectNumber 171 }
vErrOverTempExhaust OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(172) OverTemp.Exhaust"
::= { vSystemErrorInDirectNumber 172 }
vErrOverTempDMDB OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(173) OverTemp.DMD-B"
::= { vSystemErrorInDirectNumber 173 }
vErrBulbEntry OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(174) Bulb Entry"
::= { vSystemErrorInDirectNumber 174 }
vErrTamperFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(177) Tamper Fail"
::= { vSystemErrorInDirectNumber 177 }
vErrMarriageTamperFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(178) Marriage Tamper Fail"
::= { vSystemErrorInDirectNumber 178 }
vErrCPUFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(180) CPU Fail"
::= { vSystemErrorInDirectNumber 180 }
vErrGPSU24VFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(187) GPSU (24V) Fail"
::= { vSystemErrorInDirectNumber 187 }
vErrLogWriteFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(201) Error Log Write Fail"
::= { vSystemErrorInDirectNumber 201 }
vErrUnknownLPSUModel OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(210) Unknown LPSU Model"
::= { vSystemErrorInDirectNumber 210 }
vErrLPSUFanStop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(211) LPSU Fan Stop"
::= { vSystemErrorInDirectNumber 211 }
vErr12VOutsiderange OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(213) 12V Outside range"
::= { vSystemErrorInDirectNumber 213 }
vErr24VOutsiderange OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(214) 24V Outside range"
::= { vSystemErrorInDirectNumber 214 }
vErrFilterTimeOver OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
NC2000/NC1200/NC3200/NC3240
(215) Lamp Filter Time Over
NC900
(215) Filter Time Over"
::= { vSystemErrorInDirectNumber 215 }
vErrBodyFilterTimeOver OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(216) Body Filter Time Over"
::= { vSystemErrorInDirectNumber 216 }
vErrFanExchangeTime OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
NC2000/NC1200/NC3200/NC3240
(220) AC On Fan Exchange Time
NC900
(220) Fan Exchange Time"
::= { vSystemErrorInDirectNumber 220 }
vErrPowerOnFanExchangeTime OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(221) Power On Fan Exchange Time"
::= { vSystemErrorInDirectNumber 221 }
vErrLampFanExchangeTime OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(222) Lamp Fan Exchange Time"
::= { vSystemErrorInDirectNumber 222 }
vErrRouterFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(230) Router Fail"
::= { vSystemErrorInDirectNumber 230 }
vErrSensorFailOpt OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(231) SensorFail Opt"
::= { vSystemErrorInDirectNumber 231 }
vErrMACWriteFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(232) MAC Write Fail"
::= { vSystemErrorInDirectNumber 232 }
vErrIllegalMACAddress OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(233) Illegal MAC Address"
::= { vSystemErrorInDirectNumber 233 }
vErrRouterSelfCheckFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(235) Router Self Check Fail"
::= { vSystemErrorInDirectNumber 235 }
vErrRouterFirmwareUpdateFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(236) Router Firmware Update Fail"
::= { vSystemErrorInDirectNumber 236 }
vErrSIBCommFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(240) SIB Comm Fail"
::= { vSystemErrorInDirectNumber 240 }
vErrSIBError OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(241) SIB Error"
::= { vSystemErrorInDirectNumber 241 }
vErrSIBFPGAReboot OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(242) SIB FPGA Reboot"
::= { vSystemErrorInDirectNumber 242 }
vErrFan10Stop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(245) Fan10 Stop"
::= { vSystemErrorInDirectNumber 245 }
vErrFan11Stop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(246) Fan11 Stop"
::= { vSystemErrorInDirectNumber 246 }
vErrFan12Stop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(247) Fan12 Stop"
::= { vSystemErrorInDirectNumber 247 }
vErrFan13Stop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(248) Fan13 Stop"
::= { vSystemErrorInDirectNumber 248 }
vErrFan14Stop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(249) Fan14 Stop"
::= { vSystemErrorInDirectNumber 249 }
vErrFan0StopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(250) Fan0 Stop Precaution"
::= { vSystemErrorInDirectNumber 250 }
vErrFan1StopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(251) Fan1 Stop Precaution"
::= { vSystemErrorInDirectNumber 251 }
vErrFan2StopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(252) Fan2 Stop Precaution"
::= { vSystemErrorInDirectNumber 252 }
vErrFan3StopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(253) Fan3 Stop Precaution"
::= { vSystemErrorInDirectNumber 253 }
vErrFan4StopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(254) Fan4 Stop Precaution"
::= { vSystemErrorInDirectNumber 254 }
vErrFan5StopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(255) Fan5 Stop Precaution"
::= { vSystemErrorInDirectNumber 255 }
vErrFan6StopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(256) Fan6 Stop Precaution"
::= { vSystemErrorInDirectNumber 256 }
vErrFan7StopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(257) Fan7 Stop Precaution"
::= { vSystemErrorInDirectNumber 257 }
vErrFan8StopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(258) Fan8 Stop Precaution"
::= { vSystemErrorInDirectNumber 258 }
vErrFan9StopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(259) Fan9 Stop Precaution"
::= { vSystemErrorInDirectNumber 259 }
vErrLampFan0StopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(260) Lamp Fan0 Stop Precaution"
::= { vSystemErrorInDirectNumber 260 }
vErrLampFan1StopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(261) Lamp Fan1 Stop Precaution"
::= { vSystemErrorInDirectNumber 261 }
vErrPumpStopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(262) Pump Stop Precaution"
::= { vSystemErrorInDirectNumber 262 }
vErrICPFanStopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(263) ICP Fan Stop Precaution"
::= { vSystemErrorInDirectNumber 263 }
vErrFan10StopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(264) Fan10 Stop Precaution"
::= { vSystemErrorInDirectNumber 264 }
vErrFan11StopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(265) Fan11 Stop Precaution"
::= { vSystemErrorInDirectNumber 265 }
vErrFan12StopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(266) Fan12 Stop Precaution"
::= { vSystemErrorInDirectNumber 266 }
vErrFan13StopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(267) Fan13 Stop Precaution"
::= { vSystemErrorInDirectNumber 267 }
vErrFan14StopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(268) Fan14 Stop Precaution"
::= { vSystemErrorInDirectNumber 268 }
vErrSDTamperTerminate OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(270) SD Tamper Terminate"
::= { vSystemErrorInDirectNumber 270 }
vErrIMBSDTamperTerminate OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(271) IMB:SD Tamper Terminate"
::= { vSystemErrorInDirectNumber 271 }
vErrBulbWarrantyOver OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(280) Bulb Warranty Over"
::= { vSystemErrorInDirectNumber 280 }
vErrSystemError OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(301) System Error"
::= { vSystemErrorInDirectNumber 301 }
vErrSelfTestError OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(302) Self Test Error"
::= { vSystemErrorInDirectNumber 302 }
vErrInstallReleasePackage OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(303) Install Release Package Error"
::= { vSystemErrorInDirectNumber 303 }
vErrLoadReleasePackage OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(304) Load Release Package Error"
::= { vSystemErrorInDirectNumber 304 }
vErrKeyError OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(305) Key Error"
::= { vSystemErrorInDirectNumber 305 }
vErrCertificateError OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(306) Certificate Error"
::= { vSystemErrorInDirectNumber 306 }
vErrICPNormalConfiguration OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(317) ICP Normal Configuration Error"
::= { vSystemErrorInDirectNumber 317 }
vErrICPBootConfiguration OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(318) ICP Boot Configuration Error"
::= { vSystemErrorInDirectNumber 318 }
vErrFMTNormalConfiguration OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(319) FMT Normal Configuration Error"
::= { vSystemErrorInDirectNumber 319 }
vErrFMTBootConfiguration OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(320) FMT Boot Configuration Error"
::= { vSystemErrorInDirectNumber 320 }
vErrFMTSatelliteConfiguration OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(321) FMT Satellite Configuration Error"
::= { vSystemErrorInDirectNumber 321 }
vErr120VSupplyoutofrange OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(322) 1.20V Supply out of range"
::= { vSystemErrorInDirectNumber 322 }
vErr180VSupplyoutofrange OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(323) 1.80V Supply out of range"
::= { vSystemErrorInDirectNumber 323 }
vErr250VSupplyoutofrange OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(324) 2.50V Supply out of range"
::= { vSystemErrorInDirectNumber 324 }
vErr330VRegulatoroutofrange OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(325) 3.30V Regulator out of range"
::= { vSystemErrorInDirectNumber 325 }
vErrICPFPGATemperatureoutofrange OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(326) ICP FPGA Temperature out of range"
::= { vSystemErrorInDirectNumber 326 }
vErrFMTFPGATemperatureoutofrange OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(327) FMT FPGA Temperature out of range"
::= { vSystemErrorInDirectNumber 327 }
vErrICPFlashUpdate OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(328) ICP Flash Update Error"
::= { vSystemErrorInDirectNumber 328 }
vErrFMTSequenceDataFileMismatch OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(329) FMT Sequence Data File Mismatch"
::= { vSystemErrorInDirectNumber 329 }
vErrFMTDMDDataFileMismatch OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(330) FMT DMD Data File Mismatch"
::= { vSystemErrorInDirectNumber 330 }
vErrFMTFlashChecksumSequenceData OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(331) FMT Flash Checksum Error - Sequence Data"
::= { vSystemErrorInDirectNumber 331 }
vErrFMTFlashChecksumDMDData OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(332) FMT Flash Checksum Error - DMD Data"
::= { vSystemErrorInDirectNumber 332 }
vErrSatelliteHardwareMismatch OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(333) Satellite Hardware Mismatch"
::= { vSystemErrorInDirectNumber 333 }
vErrFMTFlashUpdate OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(334) FMT Flash Update Error"
::= { vSystemErrorInDirectNumber 334 }
vErrRedSatelliteReportsReset OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(335) Red Satellite Reports Reset"
::= { vSystemErrorInDirectNumber 335 }
vErrRedSatelliteSerialLink OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(336) Red Satellite Serial Link Error"
::= { vSystemErrorInDirectNumber 336 }
vErrRedSatelliteFirmwareConfiguration OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(337) Red Satellite Firmware Configuration Error"
::= { vSystemErrorInDirectNumber 337 }
vErrRedDAD1000BiasUnderVoltage OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(338) Red DAD1000 Bias Under Voltage Error"
::= { vSystemErrorInDirectNumber 338 }
vErrRedDAD1000ResetUnderVoltage OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(339) Red DAD1000 Reset Under Voltage Error"
::= { vSystemErrorInDirectNumber 339 }
vErrRedDAD1000OffsetUnderVoltage OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(340) Red DAD1000 Offset Under Voltage Error"
::= { vSystemErrorInDirectNumber 340 }
vErrRedDAD1000ThermalShutdown OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(341) Red DAD1000 Thermal Shutdown Error"
::= { vSystemErrorInDirectNumber 341 }
vErrGreenSatelliteReportsReset OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(342) Green Satellite Reports Reset"
::= { vSystemErrorInDirectNumber 342 }
vErrGreenSatelliteSerialLink OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(343) Green Satellite Serial Link Error"
::= { vSystemErrorInDirectNumber 343 }
vErrGreenSatelliteFirmwareConfiguration OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(344) Green Satellite Firmware Configuration Error"
::= { vSystemErrorInDirectNumber 344 }
vErrGreenDAD1000BiasUnderVoltage OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(345) Green DAD1000 Bias Under Voltage Error"
::= { vSystemErrorInDirectNumber 345 }
vErrGreenDAD1000ResetUnderVoltage OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(346) Green DAD1000 Reset Under Voltage Error"
::= { vSystemErrorInDirectNumber 346 }
vErrGreenDAD1000OffsetUnderVoltage OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(347) Green DAD1000 Offset Under Voltage Error"
::= { vSystemErrorInDirectNumber 347 }
vErrGreenDAD1000ThermalShutdown OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(348) Green DAD1000 Thermal Shutdown Error"
::= { vSystemErrorInDirectNumber 348 }
vErrBlueSatelliteReportsReset OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(349) Blue Satellite Reports Reset"
::= { vSystemErrorInDirectNumber 349 }
vErrBlueSatelliteSerialLink OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(350) Blue Satellite Serial Link Error"
::= { vSystemErrorInDirectNumber 350 }
vErrBlueSatelliteFirmwareConfiguration OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(351) Blue Satellite Firmware Configuration Error"
::= { vSystemErrorInDirectNumber 351 }
vErrBlueDAD1000BiasUnderVoltage OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(352) Blue DAD1000 Bias Under Voltage Error"
::= { vSystemErrorInDirectNumber 352 }
vErrBlueDAD1000ResetUnderVoltage OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(353) Blue DAD1000 Reset Under Voltage Error"
::= { vSystemErrorInDirectNumber 353 }
vErrBlueDAD1000OffsetUnderVoltage OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(354) Blue DAD1000 Offset Under Voltage Error"
::= { vSystemErrorInDirectNumber 354 }
vErrBlueDAD1000ThermalShutdown OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(355) Blue DAD1000 Thermal Shutdown Error"
::= { vSystemErrorInDirectNumber 355 }
vErrRTCError OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(356) RTC Error"
::= { vSystemErrorInDirectNumber 356 }
vErrICPFrameMemoryTestResult OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(370) ICP Frame Memory Test Result Fail"
::= { vSystemErrorInDirectNumber 370 }
vErrICPDataPathSignatureTestResult OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(372) ICP Data Path Signature Test Result Fail"
::= { vSystemErrorInDirectNumber 372 }
vErrEnigmaCommFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(400) Enigma Comm Fail"
::= { vSystemErrorInDirectNumber 400 }
vErrEnigmaSystemError OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(410) System Error"
::= { vSystemErrorInDirectNumber 410 }
vErrEnigmaSelfTestError OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(411) Self Test Error"
::= { vSystemErrorInDirectNumber 411 }
vErrEnigmaInstallReleasePackage OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(412) Install Release Package Error"
::= { vSystemErrorInDirectNumber 412 }
vErrEnigmaLoadReleasePackage OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(413) Load Release Package Error"
::= { vSystemErrorInDirectNumber 413 }
vErrEnigmaTILoginListPackage OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(414) TI Login List Package Error"
::= { vSystemErrorInDirectNumber 414 }
vErrEnigmaSecurityOfficerLoginListPackage OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(415) Security Officer Login List Package Error"
::= { vSystemErrorInDirectNumber 415 }
vErrEnigmaCertificateorKey OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(419) Certificate or Key Error"
::= { vSystemErrorInDirectNumber 419 }
vErrEnigmaICPCommunicationsStatus OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(420) ICP Communications Status"
::= { vSystemErrorInDirectNumber 420 }
vErrEnigmaUserLoaderIntegrity OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(426) User Loader Integrity Error"
::= { vSystemErrorInDirectNumber 426 }
vErrEnigmaMainApplicationIntegrity OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(427) Main Application Integrity Error"
::= { vSystemErrorInDirectNumber 427 }
vErrEnigmaRNGHardwareIntegrity OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(428) RNG Hardware Integrity Error"
::= { vSystemErrorInDirectNumber 428 }
vErrEnigmaDRNGAlgorithmIntegrity OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(429) DRNG Algorithm Integrity Error"
::= { vSystemErrorInDirectNumber 429 }
vErrEnigmaRSAAlgorithmIntegrity OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(430) RSA Algorithm Integrity Error"
::= { vSystemErrorInDirectNumber 430 }
vErrEnigmaAESAlgorithmIntegrity OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(431) AES Algorithm Integrity Error"
::= { vSystemErrorInDirectNumber 431 }
vErrEnigmaHMACAlgorithmIntegrity OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(432) HMAC Algorithm Integrity Error"
::= { vSystemErrorInDirectNumber 432 }
vErrEnigmaSHAAlgorithmIntegrity OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(433) SHA Algorithm Integrity Error"
::= { vSystemErrorInDirectNumber 433 }
vErrEnigmaTLSIntegrity OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(434) TLS Integrity Error"
::= { vSystemErrorInDirectNumber 434 }
vErrEnigmaFPGAConfigurationIntegrity OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(435) FPGA Configuration Integrity Error"
::= { vSystemErrorInDirectNumber 435 }
vErrEnigmaFPGACineLink2 OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(436) FPGA CineLink 2 Decryption Integrity Error"
::= { vSystemErrorInDirectNumber 436 }
vErrEnigmaRTCError OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(437) RTC Error"
::= { vSystemErrorInDirectNumber 437 }
vErrEnigmaFPGAConfiguration OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(442) FPGA Configuration Error"
::= { vSystemErrorInDirectNumber 442 }
vErrEnigmaFPGATemperatureoutofrange OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(443) FPGA Temperature out of range"
::= { vSystemErrorInDirectNumber 443 }
vErrEnigmaRNGHardwareDuplicateOutput OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(446) RNG Hardware Duplicate Output Error"
::= { vSystemErrorInDirectNumber 446 }
vErrEnigmaDRNGAlgorithmDuplicateOutput OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(447) DRNG Algorithm Duplicate Output Error"
::= { vSystemErrorInDirectNumber 447 }
vErrEnigma120VSupplyoutofrange OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(450) 1.20V Supply out of range"
::= { vSystemErrorInDirectNumber 450 }
vErrEnigma180VSupplyoutofrange OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(451) 1.80V Supply out of range"
::= { vSystemErrorInDirectNumber 451 }
vErrEnigma250VSupplyoutofrange OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(452) 2.50V Supply out of range"
::= { vSystemErrorInDirectNumber 452 }
vErrEnigma330VRegulatoroutofrange OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(453) 3.30V Regulator out of range"
::= { vSystemErrorInDirectNumber 453 }
vErrEnigmaSelfTestUserLoader OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(458) SelfTest User Loader Integrity Error"
::= { vSystemErrorInDirectNumber 458 }
vErrEnigmaSelfTestMainApplication OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(459) SelfTest Main Application Integrity Error"
::= { vSystemErrorInDirectNumber 459 }
vErrEnigmaSelfTestRNGHardware OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(460) SelfTest RNG Hardware Integrity Error"
::= { vSystemErrorInDirectNumber 460 }
vErrEnigmaSelfTestDRNGAlgorithm OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(461) SelfTest DRNG Algorithm Integrity Error"
::= { vSystemErrorInDirectNumber 461 }
vErrEnigmaSelfTestRSAAlgorithm OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(462) SelfTest RSA Algorithm Integrity Error"
::= { vSystemErrorInDirectNumber 462 }
vErrEnigmaSelfTestAESAlgorithm OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(463) SelfTest AES Algorithm Integrity Error"
::= { vSystemErrorInDirectNumber 463 }
vErrEnigmaSelfTestHMACAlgorithm OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(464) SelfTest HMAC Algorithm Integrity Error"
::= { vSystemErrorInDirectNumber 464 }
vErrEnigmaSelfTestSHAAlgorithm OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(465) SelfTest SHA Algorithm Integrity Error"
::= { vSystemErrorInDirectNumber 465 }
vErrEnigmaSelfTestTLSIntegrity OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(466) SelfTest TLS Integrity Error"
::= { vSystemErrorInDirectNumber 466 }
vErrEnigmaSelfTestFPGAConfiguration OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(467) SelfTest FPGA Configuration Integrity Error"
::= { vSystemErrorInDirectNumber 467 }
vErrEnigmaSelfTestFPGACineLink2 OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(468) SelfTest FPGA CineLink. 2 Decryption Integrit"
::= { vSystemErrorInDirectNumber 468 }
vErrEnigmaSecurityTamper OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(474) Security Tamper"
::= { vSystemErrorInDirectNumber 474 }
vErrEnigmaTopSideSecurityEnclosureOpen OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(475) Top Side Security Enclosure Open"
::= { vSystemErrorInDirectNumber 475 }
vErrEnigmaBottomSideSecurityEnclosureOpen OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(476) Bottom Side Security Enclosure Open"
::= { vSystemErrorInDirectNumber 476 }
vErrEnigmaSecurityBatteryEvent OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(477) Security Battery Event"
::= { vSystemErrorInDirectNumber 477 }
vErrEnigmaSoftwareCommandedZeroization OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(478) Software Commanded Zeroization"
::= { vSystemErrorInDirectNumber 478 }
vErrEnigmaSecurityEnclosureNotArmed OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(481) Security Enclosure Not Armed"
::= { vSystemErrorInDirectNumber 481 }
vErrEnigmaPhysicalMarriageTamper OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(482) Physical Marriage Tamper"
::= { vSystemErrorInDirectNumber 482 }
vErrEnigmaLogicalMarriageTamper OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(483) Logical Marriage Tamper"
::= { vSystemErrorInDirectNumber 483 }
vErrEnigmaMarriageNOTActive OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(484) Marriage NOT Active"
::= { vSystemErrorInDirectNumber 484 }
vErrEnigmaServiceDoorTamper OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(486) Service Door Tamper"
::= { vSystemErrorInDirectNumber 486 }
vErrEnigmaSecurityLog OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(487) Security Log Error"
::= { vSystemErrorInDirectNumber 487 }
vErrEnigmaSecurityBatteryLowWarning OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(488) Security Battery Low Warning"
::= { vSystemErrorInDirectNumber 488 }
vErrEnigmaSecurityLogWarning OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(489) Security Log Warning"
::= { vSystemErrorInDirectNumber 489 }
vErrIMBCommFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(500) IMB Comm Fail"
::= { vSystemErrorInDirectNumber 500 }
vErrIMBSystemError OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(510) IMB:System Error"
::= { vSystemErrorInDirectNumber 510 }
vErrIMBSelfTestError OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(511) IMB:Self Test Error"
::= { vSystemErrorInDirectNumber 511 }
vErrIMBCertificateorKey OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(519) IMB:Certificate or Key Error"
::= { vSystemErrorInDirectNumber 519 }
vErrIMBICPCommunicationsStatus OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(520) IMB:ICP Communications Status"
::= { vSystemErrorInDirectNumber 520 }
vErrIMBRTCError OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(537) IMB:RTC Error"
::= { vSystemErrorInDirectNumber 537 }
vErrIMBFPGATemperatureoutofrange OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(543) IMB:FPGA Temperature out of range"
::= { vSystemErrorInDirectNumber 543 }
vErrIMBSupplyvoltageoutofrange OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(550) IMB:Supply voltage out of range"
::= { vSystemErrorInDirectNumber 550 }
vErrIMBSecurityTamper OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(574) IMB:Security Tamper"
::= { vSystemErrorInDirectNumber 574 }
vErrIMBSecurityBatteryEvent OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(577) IMB:Security Battery Event"
::= { vSystemErrorInDirectNumber 577 }
vErrIMBSecurityEnclosureNotArmed OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(581) IMB:Security Enclosure Not Armed"
::= { vSystemErrorInDirectNumber 581 }
vErrIMBPhysicalMarriageTamper OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(582) IMB:Physical Marriage Tamper"
::= { vSystemErrorInDirectNumber 582 }
vErrIMBLogicalMarriageTamper OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(583) IMB:Logical Marriage Tamper"
::= { vSystemErrorInDirectNumber 583 }
vErrIMBMarriageNOTActive OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(584) IMB:Marriage NOT Active"
::= { vSystemErrorInDirectNumber 584 }
vErrIMBServiceDoorTamper OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(586) IMB:Service Door Tamper"
::= { vSystemErrorInDirectNumber 586 }
vErrIMBSecurityBatteryLowWarning OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(588) IMB:Security Battery Low Warning"
::= { vSystemErrorInDirectNumber 588 }
vErrSlaveCommFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(700) Slave Comm Fail"
::= { vSystemErrorInDirectNumber 700 }
vErrSlaveStatusFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(701) Slave Status Fail"
::= { vSystemErrorInDirectNumber 701 }
vErrLampLitChange OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(702) Lamp Lit Change"
::= { vSystemErrorInDirectNumber 702 }
vErrSlaveCommAckFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(703) Slave Comm Ack Fail"
::= { vSystemErrorInDirectNumber 703 }
vErrLamp1OverTime OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(710) Lamp1 OverTime"
::= { vSystemErrorInDirectNumber 710 }
vErrLamp2OverTime OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(711) Lamp2 OverTime"
::= { vSystemErrorInDirectNumber 711 }
vErrSensorFailInlet OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(740) SensorFail Inlet"
::= { vSystemErrorInDirectNumber 740 }
vErrSensorFailDMD OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(741) SensorFail DMD"
::= { vSystemErrorInDirectNumber 741 }
vErrOverTempDMDPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(750) OverTemp.DMD Precaution"
::= { vSystemErrorInDirectNumber 750 }
vErrOverTempInletPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(751) OverTemp.Inlet Precaution"
::= { vSystemErrorInDirectNumber 751 }
vErrDownLampPowerActivated OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(752) Down Lamp Power Activated"
::= { vSystemErrorInDirectNumber 752 }
vErrOverTempBallast1Precaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(753) OverTemp.Ballast1 Precaution"
::= { vSystemErrorInDirectNumber 753 }
vErrOverTempBallast2Precaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(754) OverTemp.Ballast2 Precaution"
::= { vSystemErrorInDirectNumber 754 }
vErrOverTempDMD OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(760) OverTemp.DMD"
::= { vSystemErrorInDirectNumber 760 }
vErrOverTempInlet OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(761) OverTemp.Inlet"
::= { vSystemErrorInDirectNumber 761 }
vErrOverTempLamp OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(762) OverTemp.Lamp"
::= { vSystemErrorInDirectNumber 762 }
vErrOverTempBallast1 OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(764) OverTemp.Ballast1"
::= { vSystemErrorInDirectNumber 764 }
vErrOverTempBallast2 OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(765) OverTemp.Ballast2"
::= { vSystemErrorInDirectNumber 765 }
vErrInterlockOpen OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(781) Interlock Open"
::= { vSystemErrorInDirectNumber 781 }
vErrSystemI2cFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(782) SystemI2cFail"
::= { vSystemErrorInDirectNumber 782 }
vErrEepromFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(783) EepromFail"
::= { vSystemErrorInDirectNumber 783 }
vErrEepVersionFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(784) EepVersionFail"
::= { vSystemErrorInDirectNumber 784 }
vErrSoftwareI2cFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(785) SoftwareI2cFail"
::= { vSystemErrorInDirectNumber 785 }
vErrPreCooling OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(786) PreCooling"
::= { vSystemErrorInDirectNumber 786 }
vErrLamp1DoorOpen OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(787) Lamp1 Door Open"
::= { vSystemErrorInDirectNumber 787 }
vErrLamp2DoorOpen OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(788) Lamp2 Door Open"
::= { vSystemErrorInDirectNumber 788 }
vErrBallast1Uart OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(789) Ballast1UartError"
::= { vSystemErrorInDirectNumber 789 }
vErrBallast2Uart OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(790) Ballast2UartError"
::= { vSystemErrorInDirectNumber 790 }
vErrFanInit OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(791) FanInitError"
::= { vSystemErrorInDirectNumber 791 }
vErrExGpioFail OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(792) ExGpioFail"
::= { vSystemErrorInDirectNumber 792 }
vErrNotchFilterOpen OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(793) Notch Filter Open"
::= { vSystemErrorInDirectNumber 793 }
vErrFan15Stop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(800) Fan15 Stop"
::= { vSystemErrorInDirectNumber 800 }
vErrFan16Stop OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(801) Fan16 Stop"
::= { vSystemErrorInDirectNumber 801 }
vErrFan15StopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(810) Fan15 Stop Precaution"
::= { vSystemErrorInDirectNumber 810 }
vErrFan16StopPrecaution OBJECT-TYPE
SYNTAX NCs2ErrorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error status of specified number.
(811) Fan16 Stop Precaution"
::= { vSystemErrorInDirectNumber 811 }
--<< vSystem 9 >>--
vNetwork OBJECT IDENTIFIER ::= { vSystem 9 }
vSystemIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The IP address for the projector system."
::= { vNetwork 1 }
vCinemaIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The IP address for the cinema boards."
::= { vNetwork 2 }
vCardIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "The IP address for the PC Card."
::= { vNetwork 3 }
--<< vSystem 10 >>--
vSetupDate OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..11))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The date when the projector was setup.
Format : `YYYY/MM/DD' + NULL
YYYY : Year
MM : Month
DD : Date"
::= { vSystem 10 }
--<< vSystem 11 >>--
vOptionSlotStatus OBJECT IDENTIFIER ::= { vSystem 11 }
vSlotB OBJECT-TYPE
SYNTAX INTEGER {
boardNone(1),
boardSIB(4),
boardIMB(5),
boardMMS(6),
boardSIB2(7),
boardNoSIB(14),
boardNoIMB(15),
boardNoMMS(16),
boardNoSIB2(17),
boardNotAvailable(20)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The status of option board in the slot-B.
boardNone : No Board
boardSIB : NC-80LB
boardIMB : IMB
boardMMS : MM3000B
boardSIB2 : NC-80DS
boardNotAvailable : Not Available"
::= { vOptionSlotStatus 1 }
vSlotA OBJECT-TYPE
SYNTAX INTEGER {
boardNone(1),
boardSIB(4),
boardIMB(5),
boardMMS(6),
boardSIB2(7),
boardNoSIB(14),
boardNoIMB(15),
boardNoMMS(16),
boardNoSIB2(17),
boardNotAvailable(20)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The status of option board in the slot-A.
boardNone : No Board
boardSIB : NC-80LB
boardIMB : IMB
boardMMS : MM3000B
boardSIB2 : NC-80DS
boardNotAvailable : Not Available"
::= { vOptionSlotStatus 2 }
--<< vSystem 12 >>--
vBoardInfo OBJECT IDENTIFIER ::= { vSystem 12 }
vSerialNoPJ OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The serial number of the projector system."
::= { vBoardInfo 1 }
vSerialNoMMS OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The serial number of the MMS."
::= { vBoardInfo 2 }
vSerialNoICP OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The serial number of the ICP board."
::= { vBoardInfo 3 }
vSerialNoEnigma OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The serial number of the Enigma board."
::= { vBoardInfo 4 }
vVerPJ OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The version of the projector system."
::= { vBoardInfo 5 }
vVerMMS OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The version of MMS."
::= { vBoardInfo 6 }
vVerICP OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The version of the ICP board.
(ICP Work Version)"
::= { vBoardInfo 7 }
vVerICPLoginList OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The login list version in the ICP board.
(ICP Login List Version)"
::= { vBoardInfo 8 }
vVerSIB OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The version of the SIB board.
(SIB Main Version)"
::= { vBoardInfo 9 }
vVerEnigma OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The version of the Enigma board.
(Enigma Version)"
::= { vBoardInfo 10 }
vVerEnigmaSOList OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The SOL version of the Enigma board.
(Enigma Security Officer List Version)"
::= { vBoardInfo 11 }
vVerSlave OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "MCU firmware version of the Slave board."
::= { vBoardInfo 12 }
vVerBallast1 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Ballast1 version of the Slave board."
::= { vBoardInfo 13 }
vVerBallast2 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Ballast2 version of the Slave board."
::= { vBoardInfo 14 }
vICPdnQualifier OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..495))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The DN Qualifier attribute in the certificate
of the ICP board."
::= { vBoardInfo 15 }
vEnigmadnQualifier OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..495))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The DN Qualifier attribute in the certificate
of the Enigma board."
::= { vBoardInfo 16 }
--<< vSystem 13 >>--
vModelName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the model name of the projector."
::= { vSystem 13 }
--<< vSystem 14 >>--
vSystemPowerSupply OBJECT IDENTIFIER ::= { vSystem 14 }
vSystemPS3V OBJECT-TYPE
SYNTAX INTEGER(-1..999)
UNITS "x0.1V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current value of power supply 3.3V.
If this value is -1, it means can not get power supply.(error occured)"
::= { vSystemPowerSupply 1 }
vSystemPS5V OBJECT-TYPE
SYNTAX INTEGER(-1..999)
UNITS "x0.1V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current value of power supply 5V.
If this value is -1, it means can not get power supply.(error occured)"
::= { vSystemPowerSupply 2 }
vSystemPS12V OBJECT-TYPE
SYNTAX INTEGER(-1..999)
UNITS "x0.1V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current value of power supply 12V.
If this value is -1, it means can not get power supply.(error occured)"
::= { vSystemPowerSupply 3 }
vSystemPS24V OBJECT-TYPE
SYNTAX INTEGER(-1..999)
UNITS "x0.1V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current value of power supply 24V.
If this value is -1, it means can not get power supply.(error occured)"
::= { vSystemPowerSupply 4 }
--<< vSystem 15 >>--
vSystemFanSpeed OBJECT IDENTIFIER ::= { vSystem 15 }
vSystemFSFan0 OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Fan0.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 1 }
vSystemFSFan1 OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Fan1.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 2 }
vSystemFSFan2 OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Fan2.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 3 }
vSystemFSFan3 OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Fan3.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 4 }
vSystemFSFan4 OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Fan4.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 5 }
vSystemFSFan5 OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Fan5.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 6 }
vSystemFSFan6 OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Fan6.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 7 }
vSystemFSFan7 OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Fan7.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 8 }
vSystemFSFan8 OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Fan8.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 9 }
vSystemFSFan9 OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Fan9.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 10 }
vSystemFSFan10 OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Fan10.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 11 }
vSystemFSFan11 OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Fan11.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 12 }
vSystemFSFan12 OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Fan12.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 13 }
vSystemFSLampCoolingFan0 OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Lamp Cooling Fan0.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 14 }
vSystemFSLampCoolingFan1 OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Lamp Cooling Fan1.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 15 }
vSystemFSPump OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Pump.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 16 }
vSystemFSICPFan OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of ICP Fan.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 17 }
vSystemFSFan13 OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Fan13.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 18 }
vSystemFSFan14 OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Fan14.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 19 }
vSystemFSFan15 OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Fan15.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 20 }
vSystemFSFan16 OBJECT-TYPE
SYNTAX INTEGER(-3..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan speed of Fan16.
If this value is -1, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)
If this value is -3, it means can not get a fan speed.(overflow)"
::= { vSystemFanSpeed 21 }
--<< vSystem 16 >>--
vSystemSetting OBJECT IDENTIFIER ::= { vSystem 16 }
--<< vSystem.vSystemSetting 1 >>--
vLANSetting OBJECT IDENTIFIER ::= { vSystemSetting 1 }
vDHCP OBJECT-TYPE
SYNTAX INTEGER {
manual(1),
automatic(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "LAN Settings for the projector system.( DHCP )
( To keep setting value in temporary area. When you write the
vSettingApply, the setting is available.)"
::= { vLANSetting 1 }
vIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "LAN Settings for the projector system.( System IP Address )
( To keep setting value in temporary area. When you write the
vSettingApply, the setting is available.)"
::= { vLANSetting 2 }
vSubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "LAN Settings for the projector system.( Subnet Mask )
( To keep setting value in temporary area. When you write the
vSettingApply, the setting is available.)"
::= { vLANSetting 3 }
vPJSystemName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "LAN Settings for the projector system.( System Name )
( To keep setting value in temporary area. When you write the
vSettingApply, the setting is available.)"
::= { vLANSetting 4 }
vGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "LAN Settings for the projector system.( Gateway )
( To keep setting value in temporary area. When you write the
vSettingApply, the setting is available.)"
::= { vLANSetting 5 }
vDNS OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "LAN Settings for the projector system.( DNS Configuration )
( To keep setting value in temporary area. When you write the
vSettingApply, the setting is available.)"
::= { vLANSetting 6 }
vHostName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..19))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "LAN Settings for the projector system.( Host Name )
( To keep setting value in temporary area. When you write the
vSettingApply, the setting is available.)"
::= { vLANSetting 7 }
vDomainName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..59))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "LAN Settings for the projector system.( Domain Name )
( To keep setting value in temporary area. When you write the
vSettingApply, the setting is available.)"
::= { vLANSetting 8 }
vSettingApply OBJECT-TYPE
SYNTAX INTEGER {
execute(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Change settings in vLANSetting.
(The read value is fixed to 1. )"
::= { vLANSetting 9 }
--<< vSystem.vSystemSetting 2 >>--
vMailSetting OBJECT IDENTIFIER ::= { vSystemSetting 2 }
vAlertMail OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Mail Settings for the projector system.( Alert Mail )"
::= { vMailSetting 1 }
vSendersAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..60))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Mail Settings for the projector system.( Sender's Address )"
::= { vMailSetting 2 }
vSMTPServer OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..60))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Mail Settings for the projector system.( SMTP Server Name )"
::= { vMailSetting 3 }
vRecipientAddress1 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..60))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Mail Settings for the projector system.( Recipient's Address 1 )"
::= { vMailSetting 4 }
vRecipientAddress2 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..60))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Mail Settings for the projector system.( Recipient's Address 2 )"
::= { vMailSetting 5 }
vRecipientAddress3 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..60))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Mail Settings for the projector system.( Recipient's Address 3 )"
::= { vMailSetting 6 }
vTestMail OBJECT-TYPE
SYNTAX INTEGER {
execute(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Execute the Test Mail.
(The read value is fixed to 1. )"
::= { vMailSetting 7 }
--<< vSystem.vSystemSetting 3 >>--
vSNMPSetting OBJECT IDENTIFIER ::= { vSystemSetting 3 }
--<< vSystem.vSystemSetting.vSNMPSetting 1 >>--
vReadSetting OBJECT IDENTIFIER ::= { vSNMPSetting 1 }
vReadAcceptAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SNMP - Read Settings for the projector system.( Accept Address )"
::= { vReadSetting 1 }
vReadAcceptMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SNMP - Read Settings for the projector system.( Accept Mask )"
::= { vReadSetting 2 }
vReadCommunity OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SNMP - Read Settings for the projector system.( Community )"
::= { vReadSetting 3 }
--<< vSystem.vSystemSetting.vSNMPSetting 2 >>--
vWriteSetting OBJECT IDENTIFIER ::= { vSNMPSetting 2 }
vWriteAcceptAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SNMP - Write Settings for the projector system.( Accept Address )"
::= { vWriteSetting 1 }
vWriteAcceptMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SNMP - Write Settings for the projector system.( Accept Mask )"
::= { vWriteSetting 2 }
vWriteCommunity OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SNMP - Write Settings for the projector system.( Community )"
::= { vWriteSetting 3 }
--<< vSystem.vSystemSetting.vSNMPSetting 3 >>--
vTrapSettings OBJECT IDENTIFIER ::= { vSNMPSetting 3 }
vTrapSetting OBJECT IDENTIFIER ::= { vTrapSettings 1 }
vTrapSettingCount OBJECT-TYPE
SYNTAX INTEGER(3..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SNMP - Trap Settings for the projector system.( 3 number of settings )
(fixed number)"
::= { vTrapSetting 1 }
vTrapSettingTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrapSettingTable
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This is a hierarchical tree for the SNMP-Trap setting related to
the projector system. This object does not have a value."
::= { vTrapSetting 2 }
TrapSettingTable ::= SEQUENCE {
vTrapSettingIndex INTEGER,
vTrapSettingIPAddress IpAddress,
vTrapSettingCommunity DisplayString
}
vTrapSettingEntry OBJECT-TYPE
SYNTAX TrapSettingTable
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This is a hierarchical tree for the SNMP-Trap setting related to
the projector system. This object does not have a value."
INDEX { vTrapSettingIndex }
::= { vTrapSettingTable 1 }
vTrapSettingIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A unique value for each Trap setting. Its value ranges between 1 and
the value of vTrapSettingCount."
::= { vTrapSettingEntry 1 }
vTrapSettingIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SNMP - Trap Settings for the projector system.( IP Address )
If this value is 0.0.0.0, this setting of Trap Setting is invalid."
::= { vTrapSettingEntry 2 }
vTrapSettingCommunity OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SNMP - Trap Settings for the projector system.( Community )"
::= { vTrapSettingEntry 3 }
vTrapErrorTypeSetting OBJECT IDENTIFIER ::= { vTrapSettings 2 }
vTrapErrorTypeEntryCount OBJECT-TYPE
SYNTAX INTEGER(0..512)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of error definition."
::= { vTrapErrorTypeSetting 1 }
vTrapErrorTypeTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrapErrorTypeTable
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This is a hierarchical tree for the Error Type setting related to
the projector system. This object does not have a value."
::= { vTrapErrorTypeSetting 2 }
TrapErrorTypeTable ::= SEQUENCE {
vTrapTypeErrorIndex INTEGER,
vTrapTypeErrorNumber INTEGER,
vTrapTypeErrorCaption DisplayString,
vTrapTypeErrorSetting INTEGER
}
vTrapErrorTypeEntry OBJECT-TYPE
SYNTAX TrapErrorTypeTable
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This is a hierarchical tree for the Error Type setting related to
the projector system. This object does not have a value."
INDEX { vTrapTypeErrorIndex }
::= { vTrapErrorTypeTable 1 }
vTrapTypeErrorIndex OBJECT-TYPE
SYNTAX INTEGER(1..512)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A unique value for each Error Type setting. Its value ranges between 1
and the value of vTrapErrorTypeEntryCount."
::= { vTrapErrorTypeEntry 1 }
vTrapTypeErrorNumber OBJECT-TYPE
SYNTAX INTEGER(1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error number."
::= { vTrapErrorTypeEntry 2 }
vTrapTypeErrorCaption OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error caption."
::= { vTrapErrorTypeEntry 3 }
vTrapTypeErrorSetting OBJECT-TYPE
SYNTAX INTEGER {
errorNonCritical(1),
errorCritical(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The Error Type setting.( Critical / Non-Critical )"
::= { vTrapErrorTypeEntry 4 }
vTrapErrorTypeAllSetting OBJECT-TYPE
SYNTAX INTEGER {
errorNonCritical(1),
errorCritical(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Set the Error Type(Critical/Non-Critical) to all itmes.
(The read value is fixed to 1. )"
::= { vTrapErrorTypeSetting 3 }
vTrapFilteringTrapStatus OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The Filtering of vTrapStatus setting."
::= { vTrapSettings 3 }
vTrapFilteringTrapProtect OBJECT IDENTIFIER ::= { vTrapSettings 4 }
vTrapProtectFilteringEntryCount OBJECT-TYPE
SYNTAX INTEGER(0..512)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of error definition."
::= { vTrapFilteringTrapProtect 1 }
vTrapProtectFilteringTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrapProtectFilteringTable
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This is a hierarchical tree for the filtering setting of vTrapProtect
related to the projector system. This object does not have a value."
::= { vTrapFilteringTrapProtect 2 }
TrapProtectFilteringTable ::= SEQUENCE {
vTrapProtectFilteringIndex INTEGER,
vTrapProtectFilteringErrorNumber INTEGER,
vTrapProtectFilteringCaption DisplayString,
vTrapProtectFilteringSetting INTEGER
}
vTrapProtectFilteringEntry OBJECT-TYPE
SYNTAX TrapProtectFilteringTable
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This is a hierarchical tree for the filtering setting of vTrapProtect
related to the projector system. This object does not have a value."
INDEX { vTrapProtectFilteringIndex }
::= { vTrapProtectFilteringTable 1 }
vTrapProtectFilteringIndex OBJECT-TYPE
SYNTAX INTEGER(1..512)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A unique value for each filtering setting of vTrapProtect. Its value
ranges between 1 and the value of vTrapProtectFilteringEntryCount."
::= { vTrapProtectFilteringEntry 1 }
vTrapProtectFilteringErrorNumber OBJECT-TYPE
SYNTAX INTEGER(1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error number."
::= { vTrapProtectFilteringEntry 2 }
vTrapProtectFilteringCaption OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error caption."
::= { vTrapProtectFilteringEntry 3 }
vTrapProtectFilteringSetting OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The filtering setting of vTrapProtect."
::= { vTrapProtectFilteringEntry 4 }
vTrapFilteringTrapProtectAllSetting OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Set the Filtering setting of vTrapProtect to all itmes.
(The read value is fixed to 1. )"
::= { vTrapFilteringTrapProtect 3 }
--<< vSystem 17 >>--
vSystemFanTargetSpeed OBJECT IDENTIFIER ::= { vSystem 17 }
vSystemFTSFan1 OBJECT-TYPE
SYNTAX INTEGER(-2..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan target speed of Fan1.
If this value is 0, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)"
::= { vSystemFanTargetSpeed 1 }
vSystemFTSFan2 OBJECT-TYPE
SYNTAX INTEGER(-2..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan target speed of Fan2.
If this value is 0, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)"
::= { vSystemFanTargetSpeed 2 }
vSystemFTSFan3 OBJECT-TYPE
SYNTAX INTEGER(-2..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan target speed of Fan3.
If this value is 0, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)"
::= { vSystemFanTargetSpeed 3 }
vSystemFTSFan4 OBJECT-TYPE
SYNTAX INTEGER(-2..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan target speed of Fan4.
If this value is 0, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)"
::= { vSystemFanTargetSpeed 4 }
vSystemFTSFan5 OBJECT-TYPE
SYNTAX INTEGER(-2..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan target speed of Fan5.
If this value is 0, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)"
::= { vSystemFanTargetSpeed 5 }
vSystemFTSFan6 OBJECT-TYPE
SYNTAX INTEGER(-2..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan target speed of Fan6.
If this value is 0, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)"
::= { vSystemFanTargetSpeed 6 }
vSystemFTSFan7 OBJECT-TYPE
SYNTAX INTEGER(-2..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan target speed of Fan7.
If this value is 0, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)"
::= { vSystemFanTargetSpeed 7 }
vSystemFTSFan8 OBJECT-TYPE
SYNTAX INTEGER(-2..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan target speed of Fan8.
If this value is 0, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)"
::= { vSystemFanTargetSpeed 8 }
vSystemFTSFan9 OBJECT-TYPE
SYNTAX INTEGER(-2..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan target speed of Fan9.
If this value is 0, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)"
::= { vSystemFanTargetSpeed 9 }
vSystemFTSFan10 OBJECT-TYPE
SYNTAX INTEGER(-2..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan target speed of Fan10.
If this value is 0, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)"
::= { vSystemFanTargetSpeed 10 }
vSystemFTSFan11 OBJECT-TYPE
SYNTAX INTEGER(-2..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan target speed of Fan11.
If this value is 0, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)"
::= { vSystemFanTargetSpeed 11 }
vSystemFTSFan12 OBJECT-TYPE
SYNTAX INTEGER(-2..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan target speed of Fan12.
If this value is 0, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)"
::= { vSystemFanTargetSpeed 12 }
vSystemFTSFan13 OBJECT-TYPE
SYNTAX INTEGER(-2..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan target speed of Fan13.
If this value is 0, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)"
::= { vSystemFanTargetSpeed 13 }
vSystemFTSFan14 OBJECT-TYPE
SYNTAX INTEGER(-2..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan target speed of Fan14.
If this value is 0, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)"
::= { vSystemFanTargetSpeed 14 }
vSystemFTSFan15 OBJECT-TYPE
SYNTAX INTEGER(-2..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan target speed of Fan15.
If this value is 0, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)"
::= { vSystemFanTargetSpeed 15 }
vSystemFTSFan16 OBJECT-TYPE
SYNTAX INTEGER(-2..99999)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan target speed of Fan16.
If this value is 0, it means the fan is stopped.
If this value is -2, it means can not get a fan speed.(error)"
::= { vSystemFanTargetSpeed 16 }
vSystemFTSICPFan OBJECT-TYPE
SYNTAX INTEGER(0..5500)
UNITS "rpm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current fan target speed of ICP Fan.
If this value is 0, it means the fan is stopped."
::= { vSystemFanTargetSpeed 17 }
--
-- * vLamp **********************************************
--
vLampMode OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
eco(2)
}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vLamp 1 }
vLampNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vLamp 2 }
vLampTable OBJECT-TYPE
SYNTAX SEQUENCE OF LampEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION ""
::= { vLamp 3 }
vLampEntry OBJECT-TYPE
SYNTAX LampEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION ""
INDEX { vLampIndex }
::= { vLampTable 1 }
LampEntry ::= SEQUENCE {
vLampIndex INTEGER,
vLampType INTEGER,
vLampUsage TimeTicks,
vLampTmWarning TimeTicks,
vLampTmProtect TimeTicks
}
vLampIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vLampEntry 1 }
vLampType OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
super-eco(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vLampEntry 2 }
vLampUsage OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vLampEntry 3 }
vLampTmWarning OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vLampEntry 4 }
vLampTmProtect OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vLampEntry 5 }
vLampBulbName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..48))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Selected bulb name."
::= { vLamp 4 }
vLampOutput OBJECT IDENTIFIER ::= { vLamp 5 }
vLampOutputCurrent OBJECT-TYPE
SYNTAX INTEGER(0..9999)
UNITS "x0.1A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Getting value of output lamp bulb current from LPSU."
::= { vLampOutput 1 }
vLampOutputWattage OBJECT-TYPE
SYNTAX INTEGER(0..9999)
UNITS "W"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Getting value of output lamp bulb wattage from LPSU."
::= { vLampOutput 2 }
vLampUsage2 OBJECT IDENTIFIER ::= { vLamp 6 }
vLampBulbUsage OBJECT-TYPE
SYNTAX INTEGER(0..9999)
UNITS "H"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Lamp bulb usage.(Hour)"
::= { vLampUsage2 1 }
vLamBulbRemain OBJECT-TYPE
SYNTAX INTEGER(-9999..9999)
UNITS "H"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Lamp bulb remaining time.(Hour)"
::= { vLampUsage2 2 }
vLampHouseUsage OBJECT-TYPE
SYNTAX INTEGER(0..9999)
UNITS "H"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Lamp House usage.(Hour)"
::= { vLampUsage2 3 }
vLampStatus OBJECT-TYPE
SYNTAX INTEGER {
unlit(1),
lit(2),
litLamp1(3),
litLamp2(4),
litLamp1and2(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Lamp status."
::= { vLamp 7 }
vLampOutput2 OBJECT IDENTIFIER ::= { vLamp 8 }
vLampOutputWattage2 OBJECT-TYPE
SYNTAX INTEGER(0..9999)
UNITS "x0.1W"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Getting value of output lamp wattage."
::= { vLampOutput2 1 }
vLampOutputPer OBJECT-TYPE
SYNTAX INTEGER(0..9999)
UNITS "x0.1%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Getting value of output lamp percent."
::= { vLampOutput2 2 }
vLamp1Voltage OBJECT-TYPE
SYNTAX INTEGER(0..9999)
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Getting value of output lamp1 voltage."
::= { vLampOutput2 3 }
vLamp2Voltage OBJECT-TYPE
SYNTAX INTEGER(0..9999)
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Getting value of output lamp2 voltage."
::= { vLampOutput2 4 }
vLampUsage3 OBJECT IDENTIFIER ::= { vLamp 9 }
vLamp1Usage OBJECT-TYPE
SYNTAX INTEGER(0..99999)
UNITS "H"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Lamp1 usage.(Hour)"
::= { vLampUsage3 1 }
vLamp2Usage OBJECT-TYPE
SYNTAX INTEGER(0..99999)
UNITS "H"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Lamp2 usage.(Hour)"
::= { vLampUsage3 2 }
vLampWarning OBJECT-TYPE
SYNTAX INTEGER(0..99999)
UNITS "H"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Lamp warning time.(Hour)"
::= { vLampUsage3 3 }
vLamp1Remain OBJECT-TYPE
SYNTAX INTEGER(0..999)
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Lamp1 remainig time.(percent)"
::= { vLampUsage3 4 }
vLamp2Remain OBJECT-TYPE
SYNTAX INTEGER(0..999)
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Lamp2 remainig time.(percent)"
::= { vLampUsage3 5 }
vLamp1Strike OBJECT-TYPE
SYNTAX INTEGER(0..99999)
UNITS "Times"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Lamp1 strike count.(Times)"
::= { vLampUsage3 6 }
vLamp2Strike OBJECT-TYPE
SYNTAX INTEGER(0..99999)
UNITS "Times"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Lamp2 strike count.(Times)"
::= { vLampUsage3 7 }
vLampMode2 OBJECT-TYPE
SYNTAX INTEGER {
dual(1),
lamp1(2),
lamp2(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current lamp mode."
::= { vLamp 10 }
--
-- * vInput **********************************************
--
vInputTerminal OBJECT-TYPE
SYNTAX INTEGER {
computer1(1),
computer2(2),
video1(3),
video2(4),
svideo1(5),
svideo2(6),
rgb1-video(7),
rgb1-svideo(8),
component(9),
dvi-digital(10),
dvi-analog(11),
viewer(12),
lan(13),
testpattern(14),
slot1-1(15),
slot1-2(16),
slot2-1(17),
slot2-2(18),
unknown(19)
}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vInput 1 }
vInputSignal OBJECT IDENTIFIER ::= { vInput 2 }
vEntryList OBJECT-TYPE
SYNTAX INTEGER {
default(1),
user(2)
}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vInputSignal 1 }
vSignalNo OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vInputSignal 2 }
vSignalName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vInputSignal 3 }
vSignalFormat OBJECT-TYPE
SYNTAX INTEGER {
rgb(1),
component(2),
video(3),
s-video(4),
scart(5),
hdtv(6),
digital(7),
viewer(8),
sdi(9)
}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vInputSignal 4 }
vSignalFreqH OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vInputSignal 5 }
vSignalFreqV OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vInputSignal 6 }
vViewerSlide OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vInputSignal 7 }
vViewerTotal OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vInputSignal 8 }
vActiveTitle OBJECT IDENTIFIER ::= { vInput 3 }
vActiveTitleNumber OBJECT-TYPE
SYNTAX INTEGER(0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of Selected title.
If this value is 0, it means not to select any titles."
::= { vActiveTitle 1 }
vActiveTitleName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Name of Selected title.
If any titles are not selected, returns NULL."
::= { vActiveTitle 2 }
vActivePort OBJECT-TYPE
SYNTAX INTEGER {
portAuto(1),
port292-A(2),
port292-B(3),
port292-Dual-AB(4),
portReserved1(5),
portTestPattern(6),
portDVI-A(7),
portDVI-B(8),
portDVI-Dual-Twin(9),
portReserved2(10),
portReserved3(11),
portDVI-Dual-Twin-MMS(12),
port292-C(13),
port292-D(14),
port292-Dual-CD(15),
port292-Quad(16),
portIMB(17),
portUnknown(18)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Active Data Port of the cinema projector."
::= { vActiveTitle 3 }
vActiveSourceType OBJECT-TYPE
SYNTAX INTEGER(-1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "If active port is 292-A or B or C or D port
0x00 4:2:2 Unpacked, 10bits/Color (default)
0x01 4:2:2 Packed, 12bits/Color
0x02 4:4:4 Packed, 10bits/Color
0x03 4:4:4 Packed, 12bits/Color
If active port is 292-Dual(AB or CD),
0x00 4:2:2 Packed, 10 bits, O/E Pixels (default)
0x01 4:2:2 Packed, 10 bits, O/E Lines
0x02 4:2:2 Packed, 12 bits, O/E Pixels
0x03 4:2:2 Packed, 12 bits, O/E Lines
0x04 4:4:4 Unpacked, 10 bits
0x05 4:4:4 Packed, 10 bits, Mixed
0x06 4:4:4 Packed, 10 bits, O/E Pixels
0x07 4:4:4 Packed, 12 bits
0x08 4:2:2 Unpacked, 10 bits, O/E, Frame
0x09 4:2:2 Unpacked, 10 bits
0x0A 4:2:2 Packed, 12 bits
If active port is 292-Quad,
0x01 4:2:2 Packed, 12 bits, O/E, Frame (default)
0x02 4:4:4 Unpacked, 10 bits, O/E, Frame
0x03 4:4:4 Packed, 12 bits, O/E, Frame
If active port is DVI-A or DVI-B,
0x00 8 bits/color, Unpacked (default)
0x01 10 bits/color, Packed
0x02 12 bits/color, Packed
0x03 8 bits/color, Unpacked, 3D
If active port is DVI-Dual/Twin,
0x03 Twin: 8 bits/color, Unpacked (default)
0x04 Twin: 10 bits/color, Unpacked
0x05 Twin: 12 bits/color, Packed
0x06 Twin: 8 bits/color, Unpacked, 3D
If active port is IMB,
0x00 4:4:4 12bit (default)
0x01 4:2:2 12bit
If fails to get this information, return -1."
::= { vActiveTitle 4 }
vActivePCF OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Active PCF file name."
::= { vActiveTitle 5 }
vActiveSCREEN OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Active SCREEN file name."
::= { vActiveTitle 6 }
vAspectRatio OBJECT-TYPE
SYNTAX INTEGER (-1..8000)
UNITS "x0.001"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current aspect ratio.
If fails to get this information, return -1."
::= { vActiveTitle 7 }
vSubTitleStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current subtitle function setting."
::= { vActiveTitle 8 }
vActiveDataType OBJECT-TYPE
SYNTAX INTEGER (-1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current Data Type.
0x00 Progressive
0x01 Field Interlaced (Field Bit Normal)
0x02 Field Interlaced (Field Bit Inverted)
0x03 PsF (1st Field Dominant)
0x04 PsF (2nd Field Dominant)
If fails to get this information, return -1."
::= { vActiveTitle 9 }
vActive3D OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Active 3D file name."
::= { vActiveTitle 10 }
vTestPattern OBJECT IDENTIFIER ::= { vInput 4 }
vTestPatternStatus OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current testpattern setting."
::= { vTestPattern 1 }
vTestPatternFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Selected testpattern file name."
::= { vTestPattern 2 }
--
-- * vOutput **********************************************
--
vVolume OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vOutput 1 }
vFreeze OBJECT-TYPE
SYNTAX INTEGER {
freezeOff(1),
freezeOn(2)
}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vOutput 2 }
vMagnify OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vOutput 3 }
vMute OBJECT IDENTIFIER ::= { vOutput 4 }
vMutePicture OBJECT-TYPE
SYNTAX INTEGER {
muteOff(1),
muteOn(2)
}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vMute 1 }
vMuteSound OBJECT-TYPE
SYNTAX INTEGER {
muteOff(1),
muteOn(2)
}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vMute 2 }
vMuteOSD OBJECT-TYPE
SYNTAX INTEGER {
muteOff(1),
muteOn(2)
}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vMute 3 }
vPicture OBJECT IDENTIFIER ::= { vOutput 5 }
vBrightness OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vPicture 1 }
vContrast OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vPicture 2 }
vColor OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vPicture 3 }
vHue OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vPicture 4 }
vSharpness OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vPicture 5 }
vKeystoneH OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vPicture 6 }
vKeystoneV OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vPicture 7 }
--
-- * vSetting **********************************************
--
vLanguage OBJECT-TYPE
SYNTAX INTEGER {
lEnglish(1),
lJapanese(2),
lGerman(3),
lFrench(4),
lItalian(5),
lSpanish(6),
lSwedish(7),
lChinese(8),
lFinnish(9),
lNorwegian(10),
lDutch(11),
lTurkish(12),
lPolish(13),
lRussian(14),
lGreek(15),
lKorean(16),
lHungarian(17),
lPortuguese(18),
lOthers(19)
}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vSetting 1 }
vOrientation OBJECT-TYPE
SYNTAX INTEGER {
desktop-front(1),
ceiling-rear(2),
desktop-rear(3),
ceiling-front(4)
}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vSetting 2 }
vBackground OBJECT-TYPE
SYNTAX INTEGER {
blue(1),
black(2),
logo(3)
}
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION ""
::= { vSetting 3 }
--
-- * vTraps **********************************************
--
vTrapStatus NOTIFICATION-TYPE
OBJECTS {
vStatus,
vSystemDouser,
vActiveTitleNumber,
vTestPatternStatus
}
STATUS current
DESCRIPTION "This trap is sent, when the following status are changed.
vStatus
vSystemDouser
vActiveTitleNumber
vTestPatternStatus"
::= { vTraps 1 }
vTrapProtect NOTIFICATION-TYPE
OBJECTS { vSystemErrorCriticalCounts }
STATUS current
DESCRIPTION "This trap is sent, when the new critical error is occurred."
::= { vTraps 2 }
vTrapProtectNC NOTIFICATION-TYPE
OBJECTS { vSystemErrorNonCriticalCounts }
STATUS current
DESCRIPTION "This trap is sent, when the new error of Non-Critical is occurred."
::= { vTraps 3 }
vTrapProtectStr NOTIFICATION-TYPE
OBJECTS { vSystemErrorInformation }
STATUS current
DESCRIPTION "This trap is sent, when the new critical error is occurred."
::= { vTraps 4 }
vTrapProtectStrNC NOTIFICATION-TYPE
OBJECTS { vSystemErrorInformation }
STATUS current
DESCRIPTION "This trap is sent, when the new error of Non-Critical is occurred."
::= { vTraps 5 }
END