-- -- VIEWLIGHT-MIB -- -- VIEWLIGHT-MIB created 12/20/2011 as Version 1.06 for -- the digital cinema projector by NEC Display Solutions, Ltd. VIEWLIGHT-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, TimeTicks, Counter32, enterprises FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC; nec OBJECT IDENTIFIER ::= { enterprises 119 } necProduct OBJECT IDENTIFIER ::= { nec 1 } nec-mib OBJECT IDENTIFIER ::= { nec 2 } necProductDepend OBJECT IDENTIFIER ::= { nec-mib 3 } -- necExperimental OBJECT IDENTIFIER ::= { nec 3 } -- necProductEx OBJECT IDENTIFIER ::= { necExperimental 2 } -- -- ViewLight Private MIB -- viewlight OBJECT IDENTIFIER ::= { necProduct 123 } viewlight-mib OBJECT IDENTIFIER ::= { necProductDepend 123 } -- viewlight-ex OBJECT IDENTIFIER ::= { necProductEx 123 } vTraps OBJECT IDENTIFIER ::= { viewlight-mib 0 } vSystem OBJECT IDENTIFIER ::= { viewlight-mib 1 } vLamp OBJECT IDENTIFIER ::= { viewlight-mib 2 } vInput OBJECT IDENTIFIER ::= { viewlight-mib 3 } vOutput OBJECT IDENTIFIER ::= { viewlight-mib 4 } vSetting OBJECT IDENTIFIER ::= { viewlight-mib 5 } -- -- * vSystem ********************************************** -- --<< vSystem 1 >>-- vSystemName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the name that is set in the projector." ::= { vSystem 1 } --<< vSystem 2 >>-- vVersion OBJECT IDENTIFIER ::= { vSystem 2 } vVerBIOS OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the BIOS version number of System for the projector." ::= { vVersion 1 } vVerFirm OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the firmware version number of System for the projector." ::= { vVersion 2 } vVerData OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the data version number of System for the projector." ::= { vVersion 3 } --<< vSystem 3 >>-- vStatus OBJECT-TYPE SYNTAX INTEGER { powerOff(1), powerOn(2), cooling(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is the power supply status of the projector." ::= { vSystem 3 } --<< vSystem 4 >>-- vAlert OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vSystem 4 } --<< vSystem 5 >>-- vSystemTime OBJECT IDENTIFIER ::= { vSystem 5 } vSystemTmProjector OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This is the total usage time of the projector. (System Usage)" ::= { vSystemTime 1 } vSystemTmFilter OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vSystemTime 2 } vSystemTmFilterLamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This is the total usage time of the lamp filter." ::= { vSystemTime 3 } vSystemTmFilterBody OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This is the total usage time of the body filter." ::= { vSystemTime 4 } vSystemTmFanACOn OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This is the total usage time of the fan during ac on. (AC On Fan Usage)" ::= { vSystemTime 5 } vSystemTmFanPowerOn OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This is the total usage time of the fan during power on. (Power On Fan Usage)" ::= { vSystemTime 6 } vSystemTmFanLamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This is the total usage time of the fan during lamp on. (Lamp Fan Usage)" ::= { vSystemTime 7 } vSystemDouserCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counts of douser(open/close)." ::= { vSystemTime 8 } vSystemTmFilterUsage OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This is the total usage time of the filter." ::= { vSystemTime 9 } vSystemTmFanUsage OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This is the total usage time of the fan during power on." ::= { vSystemTime 10 } --<< vSystem 6 >>-- vSystemDouser OBJECT-TYPE SYNTAX INTEGER { open(1), close(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Douser mode setting." ::= { vSystem 6 } --<< vSystem 7 >>-- vSystemTemperature OBJECT IDENTIFIER ::= { vSystem 7 } vSystemCinemaTemp OBJECT-TYPE SYNTAX INTEGER(-1270..1270) UNITS "x0.1'C" MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Ambient temperature on the Cinema board in degrees C." ::= { vSystemTemperature 1 } vSystemChestTemp OBJECT-TYPE SYNTAX INTEGER(-1270..1270) UNITS "x0.1'C" MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Temperature on the Cinema board chest in degrees C." ::= { vSystemTemperature 2 } vSystemDMDTemp OBJECT-TYPE SYNTAX INTEGER(-1270..1270) UNITS "x0.1'C" MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Temperature on the DMD in degrees C." ::= { vSystemTemperature 3 } vSystemOutsideAirTemp OBJECT-TYPE SYNTAX INTEGER(-1270..1270) UNITS "x0.1'C" MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Temperature in the outside air in degrees C." ::= { vSystemTemperature 4 } vSystemInsideAirTemp OBJECT-TYPE SYNTAX INTEGER(-1270..1270) UNITS "x0.1'C" MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Temperature in the inside air in degrees C." ::= { vSystemTemperature 5 } vSystemRearsideAirTemp OBJECT-TYPE SYNTAX INTEGER(-1270..1270) UNITS "x0.1'C" MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Temperature in the rearside air in degrees C." ::= { vSystemTemperature 6 } vSystemCinemaMAX6656Temp OBJECT-TYPE SYNTAX INTEGER(0..1270) UNITS "x0.1'C" MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of MAX6656 on the ICP board in degrees C." ::= { vSystemTemperature 7 } vSystemCinemaICPFPGATemp OBJECT-TYPE SYNTAX INTEGER(0..1270) UNITS "x0.1'C" MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of ICP FPGA on the ICP board in degrees C." ::= { vSystemTemperature 8 } vSystemCinemaFMTFPGATemp OBJECT-TYPE SYNTAX INTEGER(0..1270) UNITS "x0.1'C" MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of FMT FPGA on the ICP board in degrees C." ::= { vSystemTemperature 9 } vSystemS2OutsideAirTemp OBJECT-TYPE SYNTAX INTEGER(-1270..1270) UNITS "x0.1'C" MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature in the outside air in degrees C." ::= { vSystemTemperature 10 } vSystemS2LPSUIntakeTemp OBJECT-TYPE SYNTAX INTEGER(-1270..1270) UNITS "x0.1'C" MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature in the LPSU Intake in degrees C." ::= { vSystemTemperature 11 } vSystemS2ExhaustTemp OBJECT-TYPE SYNTAX INTEGER(-1270..1270) UNITS "x0.1'C" MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature in the Exhaust in degrees C." ::= { vSystemTemperature 12 } vSystemS2DMDBTemp OBJECT-TYPE SYNTAX INTEGER(-1270..1270) UNITS "x0.1'C" MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature on the DMD-B in degrees C." ::= { vSystemTemperature 13 } vSystemYsTempDMD OBJECT-TYPE SYNTAX INTEGER(-200..1000) UNITS "x0.1'C" MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature on the DMD in degrees C." ::= { vSystemTemperature 14 } vSystemYsTempInlet OBJECT-TYPE SYNTAX INTEGER(-200..1000) UNITS "x0.1'C" MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature on the Inlet in degrees C." ::= { vSystemTemperature 15 } vSystemYsTempBallast1 OBJECT-TYPE SYNTAX INTEGER(-200..1000) UNITS "x0.1'C" MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature on the Ballast1 in degrees C." ::= { vSystemTemperature 16 } vSystemYsTempBallast2 OBJECT-TYPE SYNTAX INTEGER(-200..1000) UNITS "x0.1'C" MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature on the Ballast2 in degrees C." ::= { vSystemTemperature 17 } --<< vSystem 8 >>-- vSystemError OBJECT IDENTIFIER ::= { vSystem 8 } vSystemErrorCounts OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of current occurring errors." ::= { vSystemError 1 } vSystemErrorTable OBJECT-TYPE SYNTAX SEQUENCE OF SystemErrorInfo MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a hierarchical tree for the error information related to the projector system. This object does not have a value." ::= { vSystemError 2 } SystemErrorInfo ::= SEQUENCE { vSystemErrorIndex INTEGER, vSystemErrorInformation DisplayString (SIZE(0..63)) } vSystemErrorEntry OBJECT-TYPE SYNTAX SystemErrorInfo MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a hierarchical tree for the error information related to the projector system. This object does not have a value." INDEX { vSystemErrorIndex } ::= { vSystemErrorTable 1 } vSystemErrorIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "These are the characteristic numbers that are assigned to the various errors. The x within the OID can be any integer value from 1 to vSystemErrorCounts." ::= { vSystemErrorEntry 1 } vSystemErrorInformation OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the error information. The x within the OID can be any integer value from 1 to vSystemErrorCounts. Format : `YYYY/MM/DD HH:MM:SS(n) sss' + NULL YYYY : Year MM : Month DD : Date HH : Hour MM : Minute SS : Second n : number of error sss : error message" ::= { vSystemErrorEntry 2 } vSystemErrorCriticalCounts OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of current occurring errors.(Critical Error)" ::= { vSystemError 3 } vSystemErrorNonCriticalCounts OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of current occurring errors.(Non-Critical Error)" ::= { vSystemError 4 } vSystemErrorCriticalNewCounts OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of new occurring errors since last trap issued. (Critical Error)" ::= { vSystemError 5 } vSystemErrorCriticalTrapNewErrorTable OBJECT-TYPE SYNTAX SEQUENCE OF CriticalTrapNewError MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a hierarchical tree for the new occurred error table. ( Critical-Error ) This object does not have a value." ::= { vSystemError 6 } CriticalTrapNewError ::= SEQUENCE { vSystemErrorCriticalTrapNewErrorIndex INTEGER, vSystemErrorCriticalTrapNewErrorNumber INTEGER } vSystemErrorCriticalTrapNewError OBJECT-TYPE SYNTAX CriticalTrapNewError MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a hierarchical tree for the new occurred error table. ( Critical-Error ) This object does not have a value." INDEX { vSystemErrorCriticalTrapNewErrorIndex } ::= { vSystemErrorCriticalTrapNewErrorTable 1 } vSystemErrorCriticalTrapNewErrorIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "These are the characteristic numbers that are assigned to the various errors. The x within the OID can be any integer value from 1 to vSystemErrorCriticalNewCounts." ::= { vSystemErrorCriticalTrapNewError 1 } vSystemErrorCriticalTrapNewErrorNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This is the new occurred error number. ( Critical-Error )" ::= { vSystemErrorCriticalTrapNewError 2 } vSystemErrorNonCriticalNewCounts OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of new occurring errors since last trap issued. (Non-Critical Error)" ::= { vSystemError 7 } vSystemErrorNonCriticalTrapNewErrorTable OBJECT-TYPE SYNTAX SEQUENCE OF NonCriticalTrapNewError MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a hierarchical tree for the new occurred error table. ( Non-Critical-Error ) This object does not have a value." ::= { vSystemError 8 } NonCriticalTrapNewError ::= SEQUENCE { vSystemErrorNonCriticalTrapNewErrorIndex INTEGER, vSystemErrorNonCriticalTrapNewErrorNumber INTEGER } vSystemErrorNonCriticalTrapNewError OBJECT-TYPE SYNTAX NonCriticalTrapNewError MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a hierarchical tree for the new occurred error table. ( Non-Critical-Error ) This object does not have a value." INDEX { vSystemErrorNonCriticalTrapNewErrorIndex } ::= { vSystemErrorNonCriticalTrapNewErrorTable 1 } vSystemErrorNonCriticalTrapNewErrorIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "These are the characteristic numbers that are assigned to the various errors. The x within the OID can be any integer value from 1 to vSystemErrorNonCriticalNewCounts." ::= { vSystemErrorNonCriticalTrapNewError 1 } vSystemErrorNonCriticalTrapNewErrorNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This is the new occurred error number. ( Non-Critical-Error )" ::= { vSystemErrorNonCriticalTrapNewError 2 } vSystemErrorInDirectNumber OBJECT-TYPE SYNTAX SEQUENCE OF InDirectNumber MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a hierarchical tree for the system error in Direct number. This object does not have a value." ::= { vSystemError 9 } InDirectNumber ::= SEQUENCE { vErrLampDoorOpen INTEGER, vErrLampOverTemp INTEGER, vErrGPSU12VFail INTEGER, vErrLampUnlit INTEGER, vErrHouseOverTime INTEGER, vErrLPSUOverTemp INTEGER, vErrE2PROMRFail INTEGER, vErrInterlockFail INTEGER, vErrE2PROMWFail INTEGER, vErrPumpStop INTEGER, vErrDLPAckFail INTEGER, vErrLensFail INTEGER, vErrBulbOverTime INTEGER, vErrLPSUFail INTEGER, vErrOutRange INTEGER, vErrDownLampPower INTEGER, vErrMMSCommFail INTEGER, vErrMMSFanStop INTEGER, vErrMMSFail INTEGER, vErrMMReset INTEGER, vErrDLPCommRFail INTEGER, vErrDLPCommEFail INTEGER, vErrSensorFailOutsideAir INTEGER, vErrSensorFailLPSUIntake INTEGER, vErrSensorFailExhaust INTEGER, vErrSensorFailDMDB INTEGER, vErrFan0Stop INTEGER, vErrFan1Stop INTEGER, vErrFan2Stop INTEGER, vErrFan3Stop INTEGER, vErrFan4Stop INTEGER, vErrFan5Stop INTEGER, vErrFan6Stop INTEGER, vErrFan7Stop INTEGER, vErrFan8Stop INTEGER, vErrFan9Stop INTEGER, vErrGPSUFanStop INTEGER, vErrLampFan0Stop INTEGER, vErrLampFan1Stop INTEGER, vErrICPFanStop INTEGER, vErrGPIMACRO INTEGER, vErrGPIControl INTEGER, vErrOverTempOutsideAir INTEGER, vErrOverTempPrecaution INTEGER, vErrOverTempExhaust INTEGER, vErrOverTempDMDB INTEGER, vErrBulbEntry INTEGER, vErrTamperFail INTEGER, vErrMarriageTamperFail INTEGER, vErrCPUFail INTEGER, vErrGPSU24VFail INTEGER, vErrLogWriteFail INTEGER, vErrUnknownLPSUModel INTEGER, vErrLPSUFanStop INTEGER, vErr12VOutsiderange INTEGER, vErr24VOutsiderange INTEGER, vErrFilterTimeOver INTEGER, vErrBodyFilterTimeOver INTEGER, vErrFanExchangeTime INTEGER, vErrPowerOnFanExchangeTime INTEGER, vErrLampFanExchangeTime INTEGER, vErrRouterFail INTEGER, vErrSensorFailOpt INTEGER, vErrMACWriteFail INTEGER, vErrIllegalMACAddress INTEGER, vErrRouterSelfCheckFail INTEGER, vErrRouterFirmwareUpdateFail INTEGER, vErrSIBCommFail INTEGER, vErrSIBError INTEGER, vErrSIBFPGAReboot INTEGER, vErrFan10Stop INTEGER, vErrFan11Stop INTEGER, vErrFan12Stop INTEGER, vErrFan13Stop INTEGER, vErrFan14Stop INTEGER, vErrFan0StopPrecaution INTEGER, vErrFan1StopPrecaution INTEGER, vErrFan2StopPrecaution INTEGER, vErrFan3StopPrecaution INTEGER, vErrFan4StopPrecaution INTEGER, vErrFan5StopPrecaution INTEGER, vErrFan6StopPrecaution INTEGER, vErrFan7StopPrecaution INTEGER, vErrFan8StopPrecaution INTEGER, vErrFan9StopPrecaution INTEGER, vErrLampFan0StopPrecaution INTEGER, vErrLampFan1StopPrecaution INTEGER, vErrPumpStopPrecaution INTEGER, vErrICPFanStopPrecaution INTEGER, vErrFan10StopPrecaution INTEGER, vErrFan11StopPrecaution INTEGER, vErrFan12StopPrecaution INTEGER, vErrFan13StopPrecaution INTEGER, vErrFan14StopPrecaution INTEGER, vErrSDTamperTerminate INTEGER, vErrIMBSDTamperTerminate INTEGER, vErrBulbWarrantyOver INTEGER, vErrSystemError INTEGER, vErrSelfTestError INTEGER, vErrInstallReleasePackage INTEGER, vErrLoadReleasePackage INTEGER, vErrKeyError INTEGER, vErrCertificateError INTEGER, vErrICPNormalConfiguration INTEGER, vErrICPBootConfiguration INTEGER, vErrFMTNormalConfiguration INTEGER, vErrFMTBootConfiguration INTEGER, vErrFMTSatelliteConfiguration INTEGER, vErr120VSupplyoutofrange INTEGER, vErr180VSupplyoutofrange INTEGER, vErr250VSupplyoutofrange INTEGER, vErr330VRegulatoroutofrange INTEGER, vErrICPFPGATemperatureoutofrange INTEGER, vErrFMTFPGATemperatureoutofrange INTEGER, vErrICPFlashUpdate INTEGER, vErrFMTSequenceDataFileMismatch INTEGER, vErrFMTDMDDataFileMismatch INTEGER, vErrFMTFlashChecksumSequenceData INTEGER, vErrFMTFlashChecksumDMDData INTEGER, vErrSatelliteHardwareMismatch INTEGER, vErrFMTFlashUpdate INTEGER, vErrRedSatelliteReportsReset INTEGER, vErrRedSatelliteSerialLink INTEGER, vErrRedSatelliteFirmwareConfiguration INTEGER, vErrRedDAD1000BiasUnderVoltage INTEGER, vErrRedDAD1000ResetUnderVoltage INTEGER, vErrRedDAD1000OffsetUnderVoltage INTEGER, vErrRedDAD1000ThermalShutdown INTEGER, vErrGreenSatelliteReportsReset INTEGER, vErrGreenSatelliteSerialLink INTEGER, vErrGreenSatelliteFirmwareConfiguration INTEGER, vErrGreenDAD1000BiasUnderVoltage INTEGER, vErrGreenDAD1000ResetUnderVoltage INTEGER, vErrGreenDAD1000OffsetUnderVoltage INTEGER, vErrGreenDAD1000ThermalShutdown INTEGER, vErrBlueSatelliteReportsReset INTEGER, vErrBlueSatelliteSerialLink INTEGER, vErrBlueSatelliteFirmwareConfiguration INTEGER, vErrBlueDAD1000BiasUnderVoltage INTEGER, vErrBlueDAD1000ResetUnderVoltage INTEGER, vErrBlueDAD1000OffsetUnderVoltage INTEGER, vErrBlueDAD1000ThermalShutdown INTEGER, vErrRTCError INTEGER, vErrICPFrameMemoryTestResult INTEGER, vErrICPDataPathSignatureTestResult INTEGER, vErrEnigmaCommFail INTEGER, vErrEnigmaSystemError INTEGER, vErrEnigmaSelfTestError INTEGER, vErrEnigmaInstallReleasePackage INTEGER, vErrEnigmaLoadReleasePackage INTEGER, vErrEnigmaTILoginListPackage INTEGER, vErrEnigmaSecurityOfficerLoginListPackage INTEGER, vErrEnigmaCertificateorKey INTEGER, vErrEnigmaICPCommunicationsStatus INTEGER, vErrEnigmaUserLoaderIntegrity INTEGER, vErrEnigmaMainApplicationIntegrity INTEGER, vErrEnigmaRNGHardwareIntegrity INTEGER, vErrEnigmaDRNGAlgorithmIntegrity INTEGER, vErrEnigmaRSAAlgorithmIntegrity INTEGER, vErrEnigmaAESAlgorithmIntegrity INTEGER, vErrEnigmaHMACAlgorithmIntegrity INTEGER, vErrEnigmaSHAAlgorithmIntegrity INTEGER, vErrEnigmaTLSIntegrity INTEGER, vErrEnigmaFPGAConfigurationIntegrity INTEGER, vErrEnigmaFPGACineLink2 INTEGER, vErrEnigmaRTCError INTEGER, vErrEnigmaFPGAConfiguration INTEGER, vErrEnigmaFPGATemperatureoutofrange INTEGER, vErrEnigmaRNGHardwareDuplicateOutput INTEGER, vErrEnigmaDRNGAlgorithmDuplicateOutput INTEGER, vErrEnigma120VSupplyoutofrange INTEGER, vErrEnigma180VSupplyoutofrange INTEGER, vErrEnigma250VSupplyoutofrange INTEGER, vErrEnigma330VRegulatoroutofrange INTEGER, vErrEnigmaSelfTestUserLoader INTEGER, vErrEnigmaSelfTestMainApplication INTEGER, vErrEnigmaSelfTestRNGHardware INTEGER, vErrEnigmaSelfTestDRNGAlgorithm INTEGER, vErrEnigmaSelfTestRSAAlgorithm INTEGER, vErrEnigmaSelfTestAESAlgorithm INTEGER, vErrEnigmaSelfTestHMACAlgorithm INTEGER, vErrEnigmaSelfTestSHAAlgorithm INTEGER, vErrEnigmaSelfTestTLSIntegrity INTEGER, vErrEnigmaSelfTestFPGAConfiguration INTEGER, vErrEnigmaSelfTestFPGACineLink2 INTEGER, vErrEnigmaSecurityTamper INTEGER, vErrEnigmaTopSideSecurityEnclosureOpen INTEGER, vErrEnigmaBottomSideSecurityEnclosureOpen INTEGER, vErrEnigmaSecurityBatteryEvent INTEGER, vErrEnigmaSoftwareCommandedZeroization INTEGER, vErrEnigmaSecurityEnclosureNotArmed INTEGER, vErrEnigmaPhysicalMarriageTamper INTEGER, vErrEnigmaLogicalMarriageTamper INTEGER, vErrEnigmaMarriageNOTActive INTEGER, vErrEnigmaServiceDoorTamper INTEGER, vErrEnigmaSecurityLog INTEGER, vErrEnigmaSecurityBatteryLowWarning INTEGER, vErrEnigmaSecurityLogWarning INTEGER, vErrIMBCommFail INTEGER, vErrIMBSystemError INTEGER, vErrIMBSelfTestError INTEGER, vErrIMBCertificateorKey INTEGER, vErrIMBICPCommunicationsStatus INTEGER, vErrIMBRTCError INTEGER, vErrIMBFPGATemperatureoutofrange INTEGER, vErrIMBSupplyvoltageoutofrange INTEGER, vErrIMBSecurityTamper INTEGER, vErrIMBSecurityBatteryEvent INTEGER, vErrIMBSecurityEnclosureNotArmed INTEGER, vErrIMBPhysicalMarriageTamper INTEGER, vErrIMBLogicalMarriageTamper INTEGER, vErrIMBMarriageNOTActive INTEGER, vErrIMBServiceDoorTamper INTEGER, vErrIMBSecurityBatteryLowWarning INTEGER, vErrSlaveCommFail INTEGER, vErrSlaveStatusFail INTEGER, vErrLampLitChange INTEGER, vErrSlaveCommAckFail INTEGER, vErrLamp1OverTime INTEGER, vErrLamp2OverTime INTEGER, vErrSensorFailInlet INTEGER, vErrSensorFailDMD INTEGER, vErrOverTempDMDPrecaution INTEGER, vErrOverTempInletPrecaution INTEGER, vErrDownLampPowerActivated INTEGER, vErrOverTempBallast1Precaution INTEGER, vErrOverTempBallast2Precaution INTEGER, vErrOverTempDMD INTEGER, vErrOverTempInlet INTEGER, vErrOverTempLamp INTEGER, vErrOverTempBallast1 INTEGER, vErrOverTempBallast2 INTEGER, vErrInterlockOpen INTEGER, vErrSystemI2cFail INTEGER, vErrEepromFail INTEGER, vErrEepVersionFail INTEGER, vErrSoftwareI2cFail INTEGER, vErrPreCooling INTEGER, vErrLamp1DoorOpen INTEGER, vErrLamp2DoorOpen INTEGER, vErrBallast1Uart INTEGER, vErrBallast2Uart INTEGER, vErrFanInit INTEGER, vErrExGpioFail INTEGER, vErrNotchFilterOpen INTEGER, vErrFan15Stop INTEGER, vErrFan16Stop INTEGER, vErrFan15StopPrecaution INTEGER, vErrFan16StopPrecaution INTEGER } NCs2ErrorType ::= INTEGER { good(1), bad(2) } vErrLampDoorOpen OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (1) Lamp Door Open" ::= { vSystemErrorInDirectNumber 1 } vErrLampOverTemp OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (2) Lamp OverTemp." ::= { vSystemErrorInDirectNumber 2 } vErrGPSU12VFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (4) GPSU (12V) Fail" ::= { vSystemErrorInDirectNumber 4 } vErrLampUnlit OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (5) Lamp Unlit" ::= { vSystemErrorInDirectNumber 5 } vErrHouseOverTime OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (6) House OverTime" ::= { vSystemErrorInDirectNumber 6 } vErrLPSUOverTemp OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (8) LPSU OverTemp." ::= { vSystemErrorInDirectNumber 8 } vErrE2PROMRFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (12) E2PROM R Fail" ::= { vSystemErrorInDirectNumber 12 } vErrInterlockFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (13) Interlock Fail" ::= { vSystemErrorInDirectNumber 13 } vErrE2PROMWFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (15) E2PROM W Fail" ::= { vSystemErrorInDirectNumber 15 } vErrPumpStop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (17) Pump Stop" ::= { vSystemErrorInDirectNumber 17 } vErrDLPAckFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (120) DLP Ack Fail" ::= { vSystemErrorInDirectNumber 120 } vErrLensFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (121) Lens Fail" ::= { vSystemErrorInDirectNumber 121 } vErrBulbOverTime OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (123) Bulb OverTime" ::= { vSystemErrorInDirectNumber 123 } vErrLPSUFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (125) LPSU Fail" ::= { vSystemErrorInDirectNumber 125 } vErrOutRange OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (128) OutRange" ::= { vSystemErrorInDirectNumber 128 } vErrDownLampPower OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (129) Down Lamp Power" ::= { vSystemErrorInDirectNumber 129 } vErrMMSCommFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (130) MMS Comm Fail" ::= { vSystemErrorInDirectNumber 130 } vErrMMSFanStop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (131) MMS Fan Stop" ::= { vSystemErrorInDirectNumber 131 } vErrMMSFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (132) MMS Fail" ::= { vSystemErrorInDirectNumber 132 } vErrMMReset OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (133) MM Reset" ::= { vSystemErrorInDirectNumber 133 } vErrDLPCommRFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (140) DLP CommR Fail" ::= { vSystemErrorInDirectNumber 140 } vErrDLPCommEFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (141) DLP CommE Fail" ::= { vSystemErrorInDirectNumber 141 } vErrSensorFailOutsideAir OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (145) SensorFail Outside Air" ::= { vSystemErrorInDirectNumber 145 } vErrSensorFailLPSUIntake OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (146) SensorFail LPSU Intake" ::= { vSystemErrorInDirectNumber 146 } vErrSensorFailExhaust OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (147) SensorFail Exhaust" ::= { vSystemErrorInDirectNumber 147 } vErrSensorFailDMDB OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (148) SensorFail DMD-B" ::= { vSystemErrorInDirectNumber 148 } vErrFan0Stop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (150) Fan0 Stop" ::= { vSystemErrorInDirectNumber 150 } vErrFan1Stop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (151) Fan1 Stop" ::= { vSystemErrorInDirectNumber 151 } vErrFan2Stop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (152) Fan2 Stop" ::= { vSystemErrorInDirectNumber 152 } vErrFan3Stop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (153) Fan3 Stop" ::= { vSystemErrorInDirectNumber 153 } vErrFan4Stop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (154) Fan4 Stop" ::= { vSystemErrorInDirectNumber 154 } vErrFan5Stop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (155) Fan5 Stop" ::= { vSystemErrorInDirectNumber 155 } vErrFan6Stop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (156) Fan6 Stop" ::= { vSystemErrorInDirectNumber 156 } vErrFan7Stop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (157) Fan7 Stop" ::= { vSystemErrorInDirectNumber 157 } vErrFan8Stop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (158) Fan8 Stop" ::= { vSystemErrorInDirectNumber 158 } vErrFan9Stop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (159) Fan9 Stop" ::= { vSystemErrorInDirectNumber 159 } vErrGPSUFanStop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (160) GPSU Fan Stop" ::= { vSystemErrorInDirectNumber 160 } vErrLampFan0Stop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (162) Lamp Fan0 Stop" ::= { vSystemErrorInDirectNumber 162 } vErrLampFan1Stop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (163) Lamp Fan1 Stop" ::= { vSystemErrorInDirectNumber 163 } vErrICPFanStop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (164) ICP Fan Stop" ::= { vSystemErrorInDirectNumber 164 } vErrGPIMACRO OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (165) GPI MACRO Selection Invalid" ::= { vSystemErrorInDirectNumber 165 } vErrGPIControl OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (166) GPI Control Invalid" ::= { vSystemErrorInDirectNumber 166 } vErrOverTempOutsideAir OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (170) OverTemp.Outside Air" ::= { vSystemErrorInDirectNumber 170 } vErrOverTempPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (171) OverTemp Precaution" ::= { vSystemErrorInDirectNumber 171 } vErrOverTempExhaust OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (172) OverTemp.Exhaust" ::= { vSystemErrorInDirectNumber 172 } vErrOverTempDMDB OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (173) OverTemp.DMD-B" ::= { vSystemErrorInDirectNumber 173 } vErrBulbEntry OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (174) Bulb Entry" ::= { vSystemErrorInDirectNumber 174 } vErrTamperFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (177) Tamper Fail" ::= { vSystemErrorInDirectNumber 177 } vErrMarriageTamperFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (178) Marriage Tamper Fail" ::= { vSystemErrorInDirectNumber 178 } vErrCPUFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (180) CPU Fail" ::= { vSystemErrorInDirectNumber 180 } vErrGPSU24VFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (187) GPSU (24V) Fail" ::= { vSystemErrorInDirectNumber 187 } vErrLogWriteFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (201) Error Log Write Fail" ::= { vSystemErrorInDirectNumber 201 } vErrUnknownLPSUModel OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (210) Unknown LPSU Model" ::= { vSystemErrorInDirectNumber 210 } vErrLPSUFanStop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (211) LPSU Fan Stop" ::= { vSystemErrorInDirectNumber 211 } vErr12VOutsiderange OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (213) 12V Outside range" ::= { vSystemErrorInDirectNumber 213 } vErr24VOutsiderange OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (214) 24V Outside range" ::= { vSystemErrorInDirectNumber 214 } vErrFilterTimeOver OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. NC2000/NC1200/NC3200/NC3240 (215) Lamp Filter Time Over NC900 (215) Filter Time Over" ::= { vSystemErrorInDirectNumber 215 } vErrBodyFilterTimeOver OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (216) Body Filter Time Over" ::= { vSystemErrorInDirectNumber 216 } vErrFanExchangeTime OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. NC2000/NC1200/NC3200/NC3240 (220) AC On Fan Exchange Time NC900 (220) Fan Exchange Time" ::= { vSystemErrorInDirectNumber 220 } vErrPowerOnFanExchangeTime OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (221) Power On Fan Exchange Time" ::= { vSystemErrorInDirectNumber 221 } vErrLampFanExchangeTime OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (222) Lamp Fan Exchange Time" ::= { vSystemErrorInDirectNumber 222 } vErrRouterFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (230) Router Fail" ::= { vSystemErrorInDirectNumber 230 } vErrSensorFailOpt OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (231) SensorFail Opt" ::= { vSystemErrorInDirectNumber 231 } vErrMACWriteFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (232) MAC Write Fail" ::= { vSystemErrorInDirectNumber 232 } vErrIllegalMACAddress OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (233) Illegal MAC Address" ::= { vSystemErrorInDirectNumber 233 } vErrRouterSelfCheckFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (235) Router Self Check Fail" ::= { vSystemErrorInDirectNumber 235 } vErrRouterFirmwareUpdateFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (236) Router Firmware Update Fail" ::= { vSystemErrorInDirectNumber 236 } vErrSIBCommFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (240) SIB Comm Fail" ::= { vSystemErrorInDirectNumber 240 } vErrSIBError OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (241) SIB Error" ::= { vSystemErrorInDirectNumber 241 } vErrSIBFPGAReboot OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (242) SIB FPGA Reboot" ::= { vSystemErrorInDirectNumber 242 } vErrFan10Stop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (245) Fan10 Stop" ::= { vSystemErrorInDirectNumber 245 } vErrFan11Stop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (246) Fan11 Stop" ::= { vSystemErrorInDirectNumber 246 } vErrFan12Stop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (247) Fan12 Stop" ::= { vSystemErrorInDirectNumber 247 } vErrFan13Stop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (248) Fan13 Stop" ::= { vSystemErrorInDirectNumber 248 } vErrFan14Stop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (249) Fan14 Stop" ::= { vSystemErrorInDirectNumber 249 } vErrFan0StopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (250) Fan0 Stop Precaution" ::= { vSystemErrorInDirectNumber 250 } vErrFan1StopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (251) Fan1 Stop Precaution" ::= { vSystemErrorInDirectNumber 251 } vErrFan2StopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (252) Fan2 Stop Precaution" ::= { vSystemErrorInDirectNumber 252 } vErrFan3StopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (253) Fan3 Stop Precaution" ::= { vSystemErrorInDirectNumber 253 } vErrFan4StopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (254) Fan4 Stop Precaution" ::= { vSystemErrorInDirectNumber 254 } vErrFan5StopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (255) Fan5 Stop Precaution" ::= { vSystemErrorInDirectNumber 255 } vErrFan6StopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (256) Fan6 Stop Precaution" ::= { vSystemErrorInDirectNumber 256 } vErrFan7StopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (257) Fan7 Stop Precaution" ::= { vSystemErrorInDirectNumber 257 } vErrFan8StopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (258) Fan8 Stop Precaution" ::= { vSystemErrorInDirectNumber 258 } vErrFan9StopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (259) Fan9 Stop Precaution" ::= { vSystemErrorInDirectNumber 259 } vErrLampFan0StopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (260) Lamp Fan0 Stop Precaution" ::= { vSystemErrorInDirectNumber 260 } vErrLampFan1StopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (261) Lamp Fan1 Stop Precaution" ::= { vSystemErrorInDirectNumber 261 } vErrPumpStopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (262) Pump Stop Precaution" ::= { vSystemErrorInDirectNumber 262 } vErrICPFanStopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (263) ICP Fan Stop Precaution" ::= { vSystemErrorInDirectNumber 263 } vErrFan10StopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (264) Fan10 Stop Precaution" ::= { vSystemErrorInDirectNumber 264 } vErrFan11StopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (265) Fan11 Stop Precaution" ::= { vSystemErrorInDirectNumber 265 } vErrFan12StopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (266) Fan12 Stop Precaution" ::= { vSystemErrorInDirectNumber 266 } vErrFan13StopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (267) Fan13 Stop Precaution" ::= { vSystemErrorInDirectNumber 267 } vErrFan14StopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (268) Fan14 Stop Precaution" ::= { vSystemErrorInDirectNumber 268 } vErrSDTamperTerminate OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (270) SD Tamper Terminate" ::= { vSystemErrorInDirectNumber 270 } vErrIMBSDTamperTerminate OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (271) IMB:SD Tamper Terminate" ::= { vSystemErrorInDirectNumber 271 } vErrBulbWarrantyOver OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (280) Bulb Warranty Over" ::= { vSystemErrorInDirectNumber 280 } vErrSystemError OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (301) System Error" ::= { vSystemErrorInDirectNumber 301 } vErrSelfTestError OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (302) Self Test Error" ::= { vSystemErrorInDirectNumber 302 } vErrInstallReleasePackage OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (303) Install Release Package Error" ::= { vSystemErrorInDirectNumber 303 } vErrLoadReleasePackage OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (304) Load Release Package Error" ::= { vSystemErrorInDirectNumber 304 } vErrKeyError OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (305) Key Error" ::= { vSystemErrorInDirectNumber 305 } vErrCertificateError OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (306) Certificate Error" ::= { vSystemErrorInDirectNumber 306 } vErrICPNormalConfiguration OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (317) ICP Normal Configuration Error" ::= { vSystemErrorInDirectNumber 317 } vErrICPBootConfiguration OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (318) ICP Boot Configuration Error" ::= { vSystemErrorInDirectNumber 318 } vErrFMTNormalConfiguration OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (319) FMT Normal Configuration Error" ::= { vSystemErrorInDirectNumber 319 } vErrFMTBootConfiguration OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (320) FMT Boot Configuration Error" ::= { vSystemErrorInDirectNumber 320 } vErrFMTSatelliteConfiguration OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (321) FMT Satellite Configuration Error" ::= { vSystemErrorInDirectNumber 321 } vErr120VSupplyoutofrange OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (322) 1.20V Supply out of range" ::= { vSystemErrorInDirectNumber 322 } vErr180VSupplyoutofrange OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (323) 1.80V Supply out of range" ::= { vSystemErrorInDirectNumber 323 } vErr250VSupplyoutofrange OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (324) 2.50V Supply out of range" ::= { vSystemErrorInDirectNumber 324 } vErr330VRegulatoroutofrange OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (325) 3.30V Regulator out of range" ::= { vSystemErrorInDirectNumber 325 } vErrICPFPGATemperatureoutofrange OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (326) ICP FPGA Temperature out of range" ::= { vSystemErrorInDirectNumber 326 } vErrFMTFPGATemperatureoutofrange OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (327) FMT FPGA Temperature out of range" ::= { vSystemErrorInDirectNumber 327 } vErrICPFlashUpdate OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (328) ICP Flash Update Error" ::= { vSystemErrorInDirectNumber 328 } vErrFMTSequenceDataFileMismatch OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (329) FMT Sequence Data File Mismatch" ::= { vSystemErrorInDirectNumber 329 } vErrFMTDMDDataFileMismatch OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (330) FMT DMD Data File Mismatch" ::= { vSystemErrorInDirectNumber 330 } vErrFMTFlashChecksumSequenceData OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (331) FMT Flash Checksum Error - Sequence Data" ::= { vSystemErrorInDirectNumber 331 } vErrFMTFlashChecksumDMDData OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (332) FMT Flash Checksum Error - DMD Data" ::= { vSystemErrorInDirectNumber 332 } vErrSatelliteHardwareMismatch OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (333) Satellite Hardware Mismatch" ::= { vSystemErrorInDirectNumber 333 } vErrFMTFlashUpdate OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (334) FMT Flash Update Error" ::= { vSystemErrorInDirectNumber 334 } vErrRedSatelliteReportsReset OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (335) Red Satellite Reports Reset" ::= { vSystemErrorInDirectNumber 335 } vErrRedSatelliteSerialLink OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (336) Red Satellite Serial Link Error" ::= { vSystemErrorInDirectNumber 336 } vErrRedSatelliteFirmwareConfiguration OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (337) Red Satellite Firmware Configuration Error" ::= { vSystemErrorInDirectNumber 337 } vErrRedDAD1000BiasUnderVoltage OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (338) Red DAD1000 Bias Under Voltage Error" ::= { vSystemErrorInDirectNumber 338 } vErrRedDAD1000ResetUnderVoltage OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (339) Red DAD1000 Reset Under Voltage Error" ::= { vSystemErrorInDirectNumber 339 } vErrRedDAD1000OffsetUnderVoltage OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (340) Red DAD1000 Offset Under Voltage Error" ::= { vSystemErrorInDirectNumber 340 } vErrRedDAD1000ThermalShutdown OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (341) Red DAD1000 Thermal Shutdown Error" ::= { vSystemErrorInDirectNumber 341 } vErrGreenSatelliteReportsReset OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (342) Green Satellite Reports Reset" ::= { vSystemErrorInDirectNumber 342 } vErrGreenSatelliteSerialLink OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (343) Green Satellite Serial Link Error" ::= { vSystemErrorInDirectNumber 343 } vErrGreenSatelliteFirmwareConfiguration OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (344) Green Satellite Firmware Configuration Error" ::= { vSystemErrorInDirectNumber 344 } vErrGreenDAD1000BiasUnderVoltage OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (345) Green DAD1000 Bias Under Voltage Error" ::= { vSystemErrorInDirectNumber 345 } vErrGreenDAD1000ResetUnderVoltage OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (346) Green DAD1000 Reset Under Voltage Error" ::= { vSystemErrorInDirectNumber 346 } vErrGreenDAD1000OffsetUnderVoltage OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (347) Green DAD1000 Offset Under Voltage Error" ::= { vSystemErrorInDirectNumber 347 } vErrGreenDAD1000ThermalShutdown OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (348) Green DAD1000 Thermal Shutdown Error" ::= { vSystemErrorInDirectNumber 348 } vErrBlueSatelliteReportsReset OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (349) Blue Satellite Reports Reset" ::= { vSystemErrorInDirectNumber 349 } vErrBlueSatelliteSerialLink OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (350) Blue Satellite Serial Link Error" ::= { vSystemErrorInDirectNumber 350 } vErrBlueSatelliteFirmwareConfiguration OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (351) Blue Satellite Firmware Configuration Error" ::= { vSystemErrorInDirectNumber 351 } vErrBlueDAD1000BiasUnderVoltage OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (352) Blue DAD1000 Bias Under Voltage Error" ::= { vSystemErrorInDirectNumber 352 } vErrBlueDAD1000ResetUnderVoltage OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (353) Blue DAD1000 Reset Under Voltage Error" ::= { vSystemErrorInDirectNumber 353 } vErrBlueDAD1000OffsetUnderVoltage OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (354) Blue DAD1000 Offset Under Voltage Error" ::= { vSystemErrorInDirectNumber 354 } vErrBlueDAD1000ThermalShutdown OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (355) Blue DAD1000 Thermal Shutdown Error" ::= { vSystemErrorInDirectNumber 355 } vErrRTCError OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (356) RTC Error" ::= { vSystemErrorInDirectNumber 356 } vErrICPFrameMemoryTestResult OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (370) ICP Frame Memory Test Result Fail" ::= { vSystemErrorInDirectNumber 370 } vErrICPDataPathSignatureTestResult OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (372) ICP Data Path Signature Test Result Fail" ::= { vSystemErrorInDirectNumber 372 } vErrEnigmaCommFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (400) Enigma Comm Fail" ::= { vSystemErrorInDirectNumber 400 } vErrEnigmaSystemError OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (410) System Error" ::= { vSystemErrorInDirectNumber 410 } vErrEnigmaSelfTestError OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (411) Self Test Error" ::= { vSystemErrorInDirectNumber 411 } vErrEnigmaInstallReleasePackage OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (412) Install Release Package Error" ::= { vSystemErrorInDirectNumber 412 } vErrEnigmaLoadReleasePackage OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (413) Load Release Package Error" ::= { vSystemErrorInDirectNumber 413 } vErrEnigmaTILoginListPackage OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (414) TI Login List Package Error" ::= { vSystemErrorInDirectNumber 414 } vErrEnigmaSecurityOfficerLoginListPackage OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (415) Security Officer Login List Package Error" ::= { vSystemErrorInDirectNumber 415 } vErrEnigmaCertificateorKey OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (419) Certificate or Key Error" ::= { vSystemErrorInDirectNumber 419 } vErrEnigmaICPCommunicationsStatus OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (420) ICP Communications Status" ::= { vSystemErrorInDirectNumber 420 } vErrEnigmaUserLoaderIntegrity OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (426) User Loader Integrity Error" ::= { vSystemErrorInDirectNumber 426 } vErrEnigmaMainApplicationIntegrity OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (427) Main Application Integrity Error" ::= { vSystemErrorInDirectNumber 427 } vErrEnigmaRNGHardwareIntegrity OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (428) RNG Hardware Integrity Error" ::= { vSystemErrorInDirectNumber 428 } vErrEnigmaDRNGAlgorithmIntegrity OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (429) DRNG Algorithm Integrity Error" ::= { vSystemErrorInDirectNumber 429 } vErrEnigmaRSAAlgorithmIntegrity OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (430) RSA Algorithm Integrity Error" ::= { vSystemErrorInDirectNumber 430 } vErrEnigmaAESAlgorithmIntegrity OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (431) AES Algorithm Integrity Error" ::= { vSystemErrorInDirectNumber 431 } vErrEnigmaHMACAlgorithmIntegrity OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (432) HMAC Algorithm Integrity Error" ::= { vSystemErrorInDirectNumber 432 } vErrEnigmaSHAAlgorithmIntegrity OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (433) SHA Algorithm Integrity Error" ::= { vSystemErrorInDirectNumber 433 } vErrEnigmaTLSIntegrity OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (434) TLS Integrity Error" ::= { vSystemErrorInDirectNumber 434 } vErrEnigmaFPGAConfigurationIntegrity OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (435) FPGA Configuration Integrity Error" ::= { vSystemErrorInDirectNumber 435 } vErrEnigmaFPGACineLink2 OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (436) FPGA CineLink 2 Decryption Integrity Error" ::= { vSystemErrorInDirectNumber 436 } vErrEnigmaRTCError OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (437) RTC Error" ::= { vSystemErrorInDirectNumber 437 } vErrEnigmaFPGAConfiguration OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (442) FPGA Configuration Error" ::= { vSystemErrorInDirectNumber 442 } vErrEnigmaFPGATemperatureoutofrange OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (443) FPGA Temperature out of range" ::= { vSystemErrorInDirectNumber 443 } vErrEnigmaRNGHardwareDuplicateOutput OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (446) RNG Hardware Duplicate Output Error" ::= { vSystemErrorInDirectNumber 446 } vErrEnigmaDRNGAlgorithmDuplicateOutput OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (447) DRNG Algorithm Duplicate Output Error" ::= { vSystemErrorInDirectNumber 447 } vErrEnigma120VSupplyoutofrange OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (450) 1.20V Supply out of range" ::= { vSystemErrorInDirectNumber 450 } vErrEnigma180VSupplyoutofrange OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (451) 1.80V Supply out of range" ::= { vSystemErrorInDirectNumber 451 } vErrEnigma250VSupplyoutofrange OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (452) 2.50V Supply out of range" ::= { vSystemErrorInDirectNumber 452 } vErrEnigma330VRegulatoroutofrange OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (453) 3.30V Regulator out of range" ::= { vSystemErrorInDirectNumber 453 } vErrEnigmaSelfTestUserLoader OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (458) SelfTest User Loader Integrity Error" ::= { vSystemErrorInDirectNumber 458 } vErrEnigmaSelfTestMainApplication OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (459) SelfTest Main Application Integrity Error" ::= { vSystemErrorInDirectNumber 459 } vErrEnigmaSelfTestRNGHardware OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (460) SelfTest RNG Hardware Integrity Error" ::= { vSystemErrorInDirectNumber 460 } vErrEnigmaSelfTestDRNGAlgorithm OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (461) SelfTest DRNG Algorithm Integrity Error" ::= { vSystemErrorInDirectNumber 461 } vErrEnigmaSelfTestRSAAlgorithm OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (462) SelfTest RSA Algorithm Integrity Error" ::= { vSystemErrorInDirectNumber 462 } vErrEnigmaSelfTestAESAlgorithm OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (463) SelfTest AES Algorithm Integrity Error" ::= { vSystemErrorInDirectNumber 463 } vErrEnigmaSelfTestHMACAlgorithm OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (464) SelfTest HMAC Algorithm Integrity Error" ::= { vSystemErrorInDirectNumber 464 } vErrEnigmaSelfTestSHAAlgorithm OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (465) SelfTest SHA Algorithm Integrity Error" ::= { vSystemErrorInDirectNumber 465 } vErrEnigmaSelfTestTLSIntegrity OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (466) SelfTest TLS Integrity Error" ::= { vSystemErrorInDirectNumber 466 } vErrEnigmaSelfTestFPGAConfiguration OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (467) SelfTest FPGA Configuration Integrity Error" ::= { vSystemErrorInDirectNumber 467 } vErrEnigmaSelfTestFPGACineLink2 OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (468) SelfTest FPGA CineLink. 2 Decryption Integrit" ::= { vSystemErrorInDirectNumber 468 } vErrEnigmaSecurityTamper OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (474) Security Tamper" ::= { vSystemErrorInDirectNumber 474 } vErrEnigmaTopSideSecurityEnclosureOpen OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (475) Top Side Security Enclosure Open" ::= { vSystemErrorInDirectNumber 475 } vErrEnigmaBottomSideSecurityEnclosureOpen OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (476) Bottom Side Security Enclosure Open" ::= { vSystemErrorInDirectNumber 476 } vErrEnigmaSecurityBatteryEvent OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (477) Security Battery Event" ::= { vSystemErrorInDirectNumber 477 } vErrEnigmaSoftwareCommandedZeroization OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (478) Software Commanded Zeroization" ::= { vSystemErrorInDirectNumber 478 } vErrEnigmaSecurityEnclosureNotArmed OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (481) Security Enclosure Not Armed" ::= { vSystemErrorInDirectNumber 481 } vErrEnigmaPhysicalMarriageTamper OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (482) Physical Marriage Tamper" ::= { vSystemErrorInDirectNumber 482 } vErrEnigmaLogicalMarriageTamper OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (483) Logical Marriage Tamper" ::= { vSystemErrorInDirectNumber 483 } vErrEnigmaMarriageNOTActive OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (484) Marriage NOT Active" ::= { vSystemErrorInDirectNumber 484 } vErrEnigmaServiceDoorTamper OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (486) Service Door Tamper" ::= { vSystemErrorInDirectNumber 486 } vErrEnigmaSecurityLog OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (487) Security Log Error" ::= { vSystemErrorInDirectNumber 487 } vErrEnigmaSecurityBatteryLowWarning OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (488) Security Battery Low Warning" ::= { vSystemErrorInDirectNumber 488 } vErrEnigmaSecurityLogWarning OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (489) Security Log Warning" ::= { vSystemErrorInDirectNumber 489 } vErrIMBCommFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (500) IMB Comm Fail" ::= { vSystemErrorInDirectNumber 500 } vErrIMBSystemError OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (510) IMB:System Error" ::= { vSystemErrorInDirectNumber 510 } vErrIMBSelfTestError OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (511) IMB:Self Test Error" ::= { vSystemErrorInDirectNumber 511 } vErrIMBCertificateorKey OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (519) IMB:Certificate or Key Error" ::= { vSystemErrorInDirectNumber 519 } vErrIMBICPCommunicationsStatus OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (520) IMB:ICP Communications Status" ::= { vSystemErrorInDirectNumber 520 } vErrIMBRTCError OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (537) IMB:RTC Error" ::= { vSystemErrorInDirectNumber 537 } vErrIMBFPGATemperatureoutofrange OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (543) IMB:FPGA Temperature out of range" ::= { vSystemErrorInDirectNumber 543 } vErrIMBSupplyvoltageoutofrange OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (550) IMB:Supply voltage out of range" ::= { vSystemErrorInDirectNumber 550 } vErrIMBSecurityTamper OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (574) IMB:Security Tamper" ::= { vSystemErrorInDirectNumber 574 } vErrIMBSecurityBatteryEvent OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (577) IMB:Security Battery Event" ::= { vSystemErrorInDirectNumber 577 } vErrIMBSecurityEnclosureNotArmed OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (581) IMB:Security Enclosure Not Armed" ::= { vSystemErrorInDirectNumber 581 } vErrIMBPhysicalMarriageTamper OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (582) IMB:Physical Marriage Tamper" ::= { vSystemErrorInDirectNumber 582 } vErrIMBLogicalMarriageTamper OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (583) IMB:Logical Marriage Tamper" ::= { vSystemErrorInDirectNumber 583 } vErrIMBMarriageNOTActive OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (584) IMB:Marriage NOT Active" ::= { vSystemErrorInDirectNumber 584 } vErrIMBServiceDoorTamper OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (586) IMB:Service Door Tamper" ::= { vSystemErrorInDirectNumber 586 } vErrIMBSecurityBatteryLowWarning OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (588) IMB:Security Battery Low Warning" ::= { vSystemErrorInDirectNumber 588 } vErrSlaveCommFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (700) Slave Comm Fail" ::= { vSystemErrorInDirectNumber 700 } vErrSlaveStatusFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (701) Slave Status Fail" ::= { vSystemErrorInDirectNumber 701 } vErrLampLitChange OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (702) Lamp Lit Change" ::= { vSystemErrorInDirectNumber 702 } vErrSlaveCommAckFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (703) Slave Comm Ack Fail" ::= { vSystemErrorInDirectNumber 703 } vErrLamp1OverTime OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (710) Lamp1 OverTime" ::= { vSystemErrorInDirectNumber 710 } vErrLamp2OverTime OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (711) Lamp2 OverTime" ::= { vSystemErrorInDirectNumber 711 } vErrSensorFailInlet OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (740) SensorFail Inlet" ::= { vSystemErrorInDirectNumber 740 } vErrSensorFailDMD OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (741) SensorFail DMD" ::= { vSystemErrorInDirectNumber 741 } vErrOverTempDMDPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (750) OverTemp.DMD Precaution" ::= { vSystemErrorInDirectNumber 750 } vErrOverTempInletPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (751) OverTemp.Inlet Precaution" ::= { vSystemErrorInDirectNumber 751 } vErrDownLampPowerActivated OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (752) Down Lamp Power Activated" ::= { vSystemErrorInDirectNumber 752 } vErrOverTempBallast1Precaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (753) OverTemp.Ballast1 Precaution" ::= { vSystemErrorInDirectNumber 753 } vErrOverTempBallast2Precaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (754) OverTemp.Ballast2 Precaution" ::= { vSystemErrorInDirectNumber 754 } vErrOverTempDMD OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (760) OverTemp.DMD" ::= { vSystemErrorInDirectNumber 760 } vErrOverTempInlet OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (761) OverTemp.Inlet" ::= { vSystemErrorInDirectNumber 761 } vErrOverTempLamp OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (762) OverTemp.Lamp" ::= { vSystemErrorInDirectNumber 762 } vErrOverTempBallast1 OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (764) OverTemp.Ballast1" ::= { vSystemErrorInDirectNumber 764 } vErrOverTempBallast2 OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (765) OverTemp.Ballast2" ::= { vSystemErrorInDirectNumber 765 } vErrInterlockOpen OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (781) Interlock Open" ::= { vSystemErrorInDirectNumber 781 } vErrSystemI2cFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (782) SystemI2cFail" ::= { vSystemErrorInDirectNumber 782 } vErrEepromFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (783) EepromFail" ::= { vSystemErrorInDirectNumber 783 } vErrEepVersionFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (784) EepVersionFail" ::= { vSystemErrorInDirectNumber 784 } vErrSoftwareI2cFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (785) SoftwareI2cFail" ::= { vSystemErrorInDirectNumber 785 } vErrPreCooling OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (786) PreCooling" ::= { vSystemErrorInDirectNumber 786 } vErrLamp1DoorOpen OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (787) Lamp1 Door Open" ::= { vSystemErrorInDirectNumber 787 } vErrLamp2DoorOpen OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (788) Lamp2 Door Open" ::= { vSystemErrorInDirectNumber 788 } vErrBallast1Uart OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (789) Ballast1UartError" ::= { vSystemErrorInDirectNumber 789 } vErrBallast2Uart OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (790) Ballast2UartError" ::= { vSystemErrorInDirectNumber 790 } vErrFanInit OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (791) FanInitError" ::= { vSystemErrorInDirectNumber 791 } vErrExGpioFail OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (792) ExGpioFail" ::= { vSystemErrorInDirectNumber 792 } vErrNotchFilterOpen OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (793) Notch Filter Open" ::= { vSystemErrorInDirectNumber 793 } vErrFan15Stop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (800) Fan15 Stop" ::= { vSystemErrorInDirectNumber 800 } vErrFan16Stop OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (801) Fan16 Stop" ::= { vSystemErrorInDirectNumber 801 } vErrFan15StopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (810) Fan15 Stop Precaution" ::= { vSystemErrorInDirectNumber 810 } vErrFan16StopPrecaution OBJECT-TYPE SYNTAX NCs2ErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "The error status of specified number. (811) Fan16 Stop Precaution" ::= { vSystemErrorInDirectNumber 811 } --<< vSystem 9 >>-- vNetwork OBJECT IDENTIFIER ::= { vSystem 9 } vSystemIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address for the projector system." ::= { vNetwork 1 } vCinemaIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The IP address for the cinema boards." ::= { vNetwork 2 } vCardIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The IP address for the PC Card." ::= { vNetwork 3 } --<< vSystem 10 >>-- vSetupDate OBJECT-TYPE SYNTAX DisplayString (SIZE(0..11)) MAX-ACCESS read-only STATUS current DESCRIPTION "The date when the projector was setup. Format : `YYYY/MM/DD' + NULL YYYY : Year MM : Month DD : Date" ::= { vSystem 10 } --<< vSystem 11 >>-- vOptionSlotStatus OBJECT IDENTIFIER ::= { vSystem 11 } vSlotB OBJECT-TYPE SYNTAX INTEGER { boardNone(1), boardSIB(4), boardIMB(5), boardMMS(6), boardSIB2(7), boardNoSIB(14), boardNoIMB(15), boardNoMMS(16), boardNoSIB2(17), boardNotAvailable(20) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of option board in the slot-B. boardNone : No Board boardSIB : NC-80LB boardIMB : IMB boardMMS : MM3000B boardSIB2 : NC-80DS boardNotAvailable : Not Available" ::= { vOptionSlotStatus 1 } vSlotA OBJECT-TYPE SYNTAX INTEGER { boardNone(1), boardSIB(4), boardIMB(5), boardMMS(6), boardSIB2(7), boardNoSIB(14), boardNoIMB(15), boardNoMMS(16), boardNoSIB2(17), boardNotAvailable(20) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of option board in the slot-A. boardNone : No Board boardSIB : NC-80LB boardIMB : IMB boardMMS : MM3000B boardSIB2 : NC-80DS boardNotAvailable : Not Available" ::= { vOptionSlotStatus 2 } --<< vSystem 12 >>-- vBoardInfo OBJECT IDENTIFIER ::= { vSystem 12 } vSerialNoPJ OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number of the projector system." ::= { vBoardInfo 1 } vSerialNoMMS OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number of the MMS." ::= { vBoardInfo 2 } vSerialNoICP OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number of the ICP board." ::= { vBoardInfo 3 } vSerialNoEnigma OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number of the Enigma board." ::= { vBoardInfo 4 } vVerPJ OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The version of the projector system." ::= { vBoardInfo 5 } vVerMMS OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The version of MMS." ::= { vBoardInfo 6 } vVerICP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The version of the ICP board. (ICP Work Version)" ::= { vBoardInfo 7 } vVerICPLoginList OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The login list version in the ICP board. (ICP Login List Version)" ::= { vBoardInfo 8 } vVerSIB OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The version of the SIB board. (SIB Main Version)" ::= { vBoardInfo 9 } vVerEnigma OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The version of the Enigma board. (Enigma Version)" ::= { vBoardInfo 10 } vVerEnigmaSOList OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The SOL version of the Enigma board. (Enigma Security Officer List Version)" ::= { vBoardInfo 11 } vVerSlave OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "MCU firmware version of the Slave board." ::= { vBoardInfo 12 } vVerBallast1 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The Ballast1 version of the Slave board." ::= { vBoardInfo 13 } vVerBallast2 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The Ballast2 version of the Slave board." ::= { vBoardInfo 14 } vICPdnQualifier OBJECT-TYPE SYNTAX DisplayString (SIZE(0..495)) MAX-ACCESS read-only STATUS current DESCRIPTION "The DN Qualifier attribute in the certificate of the ICP board." ::= { vBoardInfo 15 } vEnigmadnQualifier OBJECT-TYPE SYNTAX DisplayString (SIZE(0..495)) MAX-ACCESS read-only STATUS current DESCRIPTION "The DN Qualifier attribute in the certificate of the Enigma board." ::= { vBoardInfo 16 } --<< vSystem 13 >>-- vModelName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the model name of the projector." ::= { vSystem 13 } --<< vSystem 14 >>-- vSystemPowerSupply OBJECT IDENTIFIER ::= { vSystem 14 } vSystemPS3V OBJECT-TYPE SYNTAX INTEGER(-1..999) UNITS "x0.1V" MAX-ACCESS read-only STATUS current DESCRIPTION "Current value of power supply 3.3V. If this value is -1, it means can not get power supply.(error occured)" ::= { vSystemPowerSupply 1 } vSystemPS5V OBJECT-TYPE SYNTAX INTEGER(-1..999) UNITS "x0.1V" MAX-ACCESS read-only STATUS current DESCRIPTION "Current value of power supply 5V. If this value is -1, it means can not get power supply.(error occured)" ::= { vSystemPowerSupply 2 } vSystemPS12V OBJECT-TYPE SYNTAX INTEGER(-1..999) UNITS "x0.1V" MAX-ACCESS read-only STATUS current DESCRIPTION "Current value of power supply 12V. If this value is -1, it means can not get power supply.(error occured)" ::= { vSystemPowerSupply 3 } vSystemPS24V OBJECT-TYPE SYNTAX INTEGER(-1..999) UNITS "x0.1V" MAX-ACCESS read-only STATUS current DESCRIPTION "Current value of power supply 24V. If this value is -1, it means can not get power supply.(error occured)" ::= { vSystemPowerSupply 4 } --<< vSystem 15 >>-- vSystemFanSpeed OBJECT IDENTIFIER ::= { vSystem 15 } vSystemFSFan0 OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Fan0. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 1 } vSystemFSFan1 OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Fan1. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 2 } vSystemFSFan2 OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Fan2. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 3 } vSystemFSFan3 OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Fan3. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 4 } vSystemFSFan4 OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Fan4. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 5 } vSystemFSFan5 OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Fan5. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 6 } vSystemFSFan6 OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Fan6. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 7 } vSystemFSFan7 OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Fan7. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 8 } vSystemFSFan8 OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Fan8. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 9 } vSystemFSFan9 OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Fan9. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 10 } vSystemFSFan10 OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Fan10. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 11 } vSystemFSFan11 OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Fan11. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 12 } vSystemFSFan12 OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Fan12. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 13 } vSystemFSLampCoolingFan0 OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Lamp Cooling Fan0. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 14 } vSystemFSLampCoolingFan1 OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Lamp Cooling Fan1. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 15 } vSystemFSPump OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Pump. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 16 } vSystemFSICPFan OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of ICP Fan. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 17 } vSystemFSFan13 OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Fan13. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 18 } vSystemFSFan14 OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Fan14. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 19 } vSystemFSFan15 OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Fan15. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 20 } vSystemFSFan16 OBJECT-TYPE SYNTAX INTEGER(-3..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan speed of Fan16. If this value is -1, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error) If this value is -3, it means can not get a fan speed.(overflow)" ::= { vSystemFanSpeed 21 } --<< vSystem 16 >>-- vSystemSetting OBJECT IDENTIFIER ::= { vSystem 16 } --<< vSystem.vSystemSetting 1 >>-- vLANSetting OBJECT IDENTIFIER ::= { vSystemSetting 1 } vDHCP OBJECT-TYPE SYNTAX INTEGER { manual(1), automatic(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "LAN Settings for the projector system.( DHCP ) ( To keep setting value in temporary area. When you write the vSettingApply, the setting is available.)" ::= { vLANSetting 1 } vIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "LAN Settings for the projector system.( System IP Address ) ( To keep setting value in temporary area. When you write the vSettingApply, the setting is available.)" ::= { vLANSetting 2 } vSubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "LAN Settings for the projector system.( Subnet Mask ) ( To keep setting value in temporary area. When you write the vSettingApply, the setting is available.)" ::= { vLANSetting 3 } vPJSystemName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "LAN Settings for the projector system.( System Name ) ( To keep setting value in temporary area. When you write the vSettingApply, the setting is available.)" ::= { vLANSetting 4 } vGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "LAN Settings for the projector system.( Gateway ) ( To keep setting value in temporary area. When you write the vSettingApply, the setting is available.)" ::= { vLANSetting 5 } vDNS OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "LAN Settings for the projector system.( DNS Configuration ) ( To keep setting value in temporary area. When you write the vSettingApply, the setting is available.)" ::= { vLANSetting 6 } vHostName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..19)) MAX-ACCESS read-write STATUS current DESCRIPTION "LAN Settings for the projector system.( Host Name ) ( To keep setting value in temporary area. When you write the vSettingApply, the setting is available.)" ::= { vLANSetting 7 } vDomainName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..59)) MAX-ACCESS read-write STATUS current DESCRIPTION "LAN Settings for the projector system.( Domain Name ) ( To keep setting value in temporary area. When you write the vSettingApply, the setting is available.)" ::= { vLANSetting 8 } vSettingApply OBJECT-TYPE SYNTAX INTEGER { execute(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Change settings in vLANSetting. (The read value is fixed to 1. )" ::= { vLANSetting 9 } --<< vSystem.vSystemSetting 2 >>-- vMailSetting OBJECT IDENTIFIER ::= { vSystemSetting 2 } vAlertMail OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Mail Settings for the projector system.( Alert Mail )" ::= { vMailSetting 1 } vSendersAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..60)) MAX-ACCESS read-write STATUS current DESCRIPTION "Mail Settings for the projector system.( Sender's Address )" ::= { vMailSetting 2 } vSMTPServer OBJECT-TYPE SYNTAX DisplayString (SIZE(0..60)) MAX-ACCESS read-write STATUS current DESCRIPTION "Mail Settings for the projector system.( SMTP Server Name )" ::= { vMailSetting 3 } vRecipientAddress1 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..60)) MAX-ACCESS read-write STATUS current DESCRIPTION "Mail Settings for the projector system.( Recipient's Address 1 )" ::= { vMailSetting 4 } vRecipientAddress2 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..60)) MAX-ACCESS read-write STATUS current DESCRIPTION "Mail Settings for the projector system.( Recipient's Address 2 )" ::= { vMailSetting 5 } vRecipientAddress3 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..60)) MAX-ACCESS read-write STATUS current DESCRIPTION "Mail Settings for the projector system.( Recipient's Address 3 )" ::= { vMailSetting 6 } vTestMail OBJECT-TYPE SYNTAX INTEGER { execute(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Execute the Test Mail. (The read value is fixed to 1. )" ::= { vMailSetting 7 } --<< vSystem.vSystemSetting 3 >>-- vSNMPSetting OBJECT IDENTIFIER ::= { vSystemSetting 3 } --<< vSystem.vSystemSetting.vSNMPSetting 1 >>-- vReadSetting OBJECT IDENTIFIER ::= { vSNMPSetting 1 } vReadAcceptAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP - Read Settings for the projector system.( Accept Address )" ::= { vReadSetting 1 } vReadAcceptMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP - Read Settings for the projector system.( Accept Mask )" ::= { vReadSetting 2 } vReadCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP - Read Settings for the projector system.( Community )" ::= { vReadSetting 3 } --<< vSystem.vSystemSetting.vSNMPSetting 2 >>-- vWriteSetting OBJECT IDENTIFIER ::= { vSNMPSetting 2 } vWriteAcceptAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP - Write Settings for the projector system.( Accept Address )" ::= { vWriteSetting 1 } vWriteAcceptMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP - Write Settings for the projector system.( Accept Mask )" ::= { vWriteSetting 2 } vWriteCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP - Write Settings for the projector system.( Community )" ::= { vWriteSetting 3 } --<< vSystem.vSystemSetting.vSNMPSetting 3 >>-- vTrapSettings OBJECT IDENTIFIER ::= { vSNMPSetting 3 } vTrapSetting OBJECT IDENTIFIER ::= { vTrapSettings 1 } vTrapSettingCount OBJECT-TYPE SYNTAX INTEGER(3..3) MAX-ACCESS read-only STATUS current DESCRIPTION "SNMP - Trap Settings for the projector system.( 3 number of settings ) (fixed number)" ::= { vTrapSetting 1 } vTrapSettingTable OBJECT-TYPE SYNTAX SEQUENCE OF TrapSettingTable MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a hierarchical tree for the SNMP-Trap setting related to the projector system. This object does not have a value." ::= { vTrapSetting 2 } TrapSettingTable ::= SEQUENCE { vTrapSettingIndex INTEGER, vTrapSettingIPAddress IpAddress, vTrapSettingCommunity DisplayString } vTrapSettingEntry OBJECT-TYPE SYNTAX TrapSettingTable MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a hierarchical tree for the SNMP-Trap setting related to the projector system. This object does not have a value." INDEX { vTrapSettingIndex } ::= { vTrapSettingTable 1 } vTrapSettingIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value for each Trap setting. Its value ranges between 1 and the value of vTrapSettingCount." ::= { vTrapSettingEntry 1 } vTrapSettingIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP - Trap Settings for the projector system.( IP Address ) If this value is 0.0.0.0, this setting of Trap Setting is invalid." ::= { vTrapSettingEntry 2 } vTrapSettingCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP - Trap Settings for the projector system.( Community )" ::= { vTrapSettingEntry 3 } vTrapErrorTypeSetting OBJECT IDENTIFIER ::= { vTrapSettings 2 } vTrapErrorTypeEntryCount OBJECT-TYPE SYNTAX INTEGER(0..512) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of error definition." ::= { vTrapErrorTypeSetting 1 } vTrapErrorTypeTable OBJECT-TYPE SYNTAX SEQUENCE OF TrapErrorTypeTable MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a hierarchical tree for the Error Type setting related to the projector system. This object does not have a value." ::= { vTrapErrorTypeSetting 2 } TrapErrorTypeTable ::= SEQUENCE { vTrapTypeErrorIndex INTEGER, vTrapTypeErrorNumber INTEGER, vTrapTypeErrorCaption DisplayString, vTrapTypeErrorSetting INTEGER } vTrapErrorTypeEntry OBJECT-TYPE SYNTAX TrapErrorTypeTable MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a hierarchical tree for the Error Type setting related to the projector system. This object does not have a value." INDEX { vTrapTypeErrorIndex } ::= { vTrapErrorTypeTable 1 } vTrapTypeErrorIndex OBJECT-TYPE SYNTAX INTEGER(1..512) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value for each Error Type setting. Its value ranges between 1 and the value of vTrapErrorTypeEntryCount." ::= { vTrapErrorTypeEntry 1 } vTrapTypeErrorNumber OBJECT-TYPE SYNTAX INTEGER(1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The error number." ::= { vTrapErrorTypeEntry 2 } vTrapTypeErrorCaption OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The error caption." ::= { vTrapErrorTypeEntry 3 } vTrapTypeErrorSetting OBJECT-TYPE SYNTAX INTEGER { errorNonCritical(1), errorCritical(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Error Type setting.( Critical / Non-Critical )" ::= { vTrapErrorTypeEntry 4 } vTrapErrorTypeAllSetting OBJECT-TYPE SYNTAX INTEGER { errorNonCritical(1), errorCritical(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the Error Type(Critical/Non-Critical) to all itmes. (The read value is fixed to 1. )" ::= { vTrapErrorTypeSetting 3 } vTrapFilteringTrapStatus OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Filtering of vTrapStatus setting." ::= { vTrapSettings 3 } vTrapFilteringTrapProtect OBJECT IDENTIFIER ::= { vTrapSettings 4 } vTrapProtectFilteringEntryCount OBJECT-TYPE SYNTAX INTEGER(0..512) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of error definition." ::= { vTrapFilteringTrapProtect 1 } vTrapProtectFilteringTable OBJECT-TYPE SYNTAX SEQUENCE OF TrapProtectFilteringTable MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a hierarchical tree for the filtering setting of vTrapProtect related to the projector system. This object does not have a value." ::= { vTrapFilteringTrapProtect 2 } TrapProtectFilteringTable ::= SEQUENCE { vTrapProtectFilteringIndex INTEGER, vTrapProtectFilteringErrorNumber INTEGER, vTrapProtectFilteringCaption DisplayString, vTrapProtectFilteringSetting INTEGER } vTrapProtectFilteringEntry OBJECT-TYPE SYNTAX TrapProtectFilteringTable MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a hierarchical tree for the filtering setting of vTrapProtect related to the projector system. This object does not have a value." INDEX { vTrapProtectFilteringIndex } ::= { vTrapProtectFilteringTable 1 } vTrapProtectFilteringIndex OBJECT-TYPE SYNTAX INTEGER(1..512) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value for each filtering setting of vTrapProtect. Its value ranges between 1 and the value of vTrapProtectFilteringEntryCount." ::= { vTrapProtectFilteringEntry 1 } vTrapProtectFilteringErrorNumber OBJECT-TYPE SYNTAX INTEGER(1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The error number." ::= { vTrapProtectFilteringEntry 2 } vTrapProtectFilteringCaption OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The error caption." ::= { vTrapProtectFilteringEntry 3 } vTrapProtectFilteringSetting OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The filtering setting of vTrapProtect." ::= { vTrapProtectFilteringEntry 4 } vTrapFilteringTrapProtectAllSetting OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the Filtering setting of vTrapProtect to all itmes. (The read value is fixed to 1. )" ::= { vTrapFilteringTrapProtect 3 } --<< vSystem 17 >>-- vSystemFanTargetSpeed OBJECT IDENTIFIER ::= { vSystem 17 } vSystemFTSFan1 OBJECT-TYPE SYNTAX INTEGER(-2..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan target speed of Fan1. If this value is 0, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error)" ::= { vSystemFanTargetSpeed 1 } vSystemFTSFan2 OBJECT-TYPE SYNTAX INTEGER(-2..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan target speed of Fan2. If this value is 0, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error)" ::= { vSystemFanTargetSpeed 2 } vSystemFTSFan3 OBJECT-TYPE SYNTAX INTEGER(-2..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan target speed of Fan3. If this value is 0, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error)" ::= { vSystemFanTargetSpeed 3 } vSystemFTSFan4 OBJECT-TYPE SYNTAX INTEGER(-2..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan target speed of Fan4. If this value is 0, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error)" ::= { vSystemFanTargetSpeed 4 } vSystemFTSFan5 OBJECT-TYPE SYNTAX INTEGER(-2..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan target speed of Fan5. If this value is 0, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error)" ::= { vSystemFanTargetSpeed 5 } vSystemFTSFan6 OBJECT-TYPE SYNTAX INTEGER(-2..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan target speed of Fan6. If this value is 0, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error)" ::= { vSystemFanTargetSpeed 6 } vSystemFTSFan7 OBJECT-TYPE SYNTAX INTEGER(-2..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan target speed of Fan7. If this value is 0, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error)" ::= { vSystemFanTargetSpeed 7 } vSystemFTSFan8 OBJECT-TYPE SYNTAX INTEGER(-2..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan target speed of Fan8. If this value is 0, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error)" ::= { vSystemFanTargetSpeed 8 } vSystemFTSFan9 OBJECT-TYPE SYNTAX INTEGER(-2..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan target speed of Fan9. If this value is 0, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error)" ::= { vSystemFanTargetSpeed 9 } vSystemFTSFan10 OBJECT-TYPE SYNTAX INTEGER(-2..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan target speed of Fan10. If this value is 0, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error)" ::= { vSystemFanTargetSpeed 10 } vSystemFTSFan11 OBJECT-TYPE SYNTAX INTEGER(-2..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan target speed of Fan11. If this value is 0, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error)" ::= { vSystemFanTargetSpeed 11 } vSystemFTSFan12 OBJECT-TYPE SYNTAX INTEGER(-2..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan target speed of Fan12. If this value is 0, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error)" ::= { vSystemFanTargetSpeed 12 } vSystemFTSFan13 OBJECT-TYPE SYNTAX INTEGER(-2..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan target speed of Fan13. If this value is 0, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error)" ::= { vSystemFanTargetSpeed 13 } vSystemFTSFan14 OBJECT-TYPE SYNTAX INTEGER(-2..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan target speed of Fan14. If this value is 0, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error)" ::= { vSystemFanTargetSpeed 14 } vSystemFTSFan15 OBJECT-TYPE SYNTAX INTEGER(-2..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan target speed of Fan15. If this value is 0, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error)" ::= { vSystemFanTargetSpeed 15 } vSystemFTSFan16 OBJECT-TYPE SYNTAX INTEGER(-2..99999) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan target speed of Fan16. If this value is 0, it means the fan is stopped. If this value is -2, it means can not get a fan speed.(error)" ::= { vSystemFanTargetSpeed 16 } vSystemFTSICPFan OBJECT-TYPE SYNTAX INTEGER(0..5500) UNITS "rpm" MAX-ACCESS read-only STATUS current DESCRIPTION "Current fan target speed of ICP Fan. If this value is 0, it means the fan is stopped." ::= { vSystemFanTargetSpeed 17 } -- -- * vLamp ********************************************** -- vLampMode OBJECT-TYPE SYNTAX INTEGER { normal(1), eco(2) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vLamp 1 } vLampNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vLamp 2 } vLampTable OBJECT-TYPE SYNTAX SEQUENCE OF LampEntry MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "" ::= { vLamp 3 } vLampEntry OBJECT-TYPE SYNTAX LampEntry MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "" INDEX { vLampIndex } ::= { vLampTable 1 } LampEntry ::= SEQUENCE { vLampIndex INTEGER, vLampType INTEGER, vLampUsage TimeTicks, vLampTmWarning TimeTicks, vLampTmProtect TimeTicks } vLampIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vLampEntry 1 } vLampType OBJECT-TYPE SYNTAX INTEGER { normal(1), super-eco(2), unknown(3) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vLampEntry 2 } vLampUsage OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vLampEntry 3 } vLampTmWarning OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vLampEntry 4 } vLampTmProtect OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vLampEntry 5 } vLampBulbName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..48)) MAX-ACCESS read-only STATUS current DESCRIPTION "Selected bulb name." ::= { vLamp 4 } vLampOutput OBJECT IDENTIFIER ::= { vLamp 5 } vLampOutputCurrent OBJECT-TYPE SYNTAX INTEGER(0..9999) UNITS "x0.1A" MAX-ACCESS read-only STATUS current DESCRIPTION "Getting value of output lamp bulb current from LPSU." ::= { vLampOutput 1 } vLampOutputWattage OBJECT-TYPE SYNTAX INTEGER(0..9999) UNITS "W" MAX-ACCESS read-only STATUS current DESCRIPTION "Getting value of output lamp bulb wattage from LPSU." ::= { vLampOutput 2 } vLampUsage2 OBJECT IDENTIFIER ::= { vLamp 6 } vLampBulbUsage OBJECT-TYPE SYNTAX INTEGER(0..9999) UNITS "H" MAX-ACCESS read-only STATUS current DESCRIPTION "Lamp bulb usage.(Hour)" ::= { vLampUsage2 1 } vLamBulbRemain OBJECT-TYPE SYNTAX INTEGER(-9999..9999) UNITS "H" MAX-ACCESS read-only STATUS current DESCRIPTION "Lamp bulb remaining time.(Hour)" ::= { vLampUsage2 2 } vLampHouseUsage OBJECT-TYPE SYNTAX INTEGER(0..9999) UNITS "H" MAX-ACCESS read-only STATUS current DESCRIPTION "Lamp House usage.(Hour)" ::= { vLampUsage2 3 } vLampStatus OBJECT-TYPE SYNTAX INTEGER { unlit(1), lit(2), litLamp1(3), litLamp2(4), litLamp1and2(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Lamp status." ::= { vLamp 7 } vLampOutput2 OBJECT IDENTIFIER ::= { vLamp 8 } vLampOutputWattage2 OBJECT-TYPE SYNTAX INTEGER(0..9999) UNITS "x0.1W" MAX-ACCESS read-only STATUS current DESCRIPTION "Getting value of output lamp wattage." ::= { vLampOutput2 1 } vLampOutputPer OBJECT-TYPE SYNTAX INTEGER(0..9999) UNITS "x0.1%" MAX-ACCESS read-only STATUS current DESCRIPTION "Getting value of output lamp percent." ::= { vLampOutput2 2 } vLamp1Voltage OBJECT-TYPE SYNTAX INTEGER(0..9999) UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "Getting value of output lamp1 voltage." ::= { vLampOutput2 3 } vLamp2Voltage OBJECT-TYPE SYNTAX INTEGER(0..9999) UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "Getting value of output lamp2 voltage." ::= { vLampOutput2 4 } vLampUsage3 OBJECT IDENTIFIER ::= { vLamp 9 } vLamp1Usage OBJECT-TYPE SYNTAX INTEGER(0..99999) UNITS "H" MAX-ACCESS read-only STATUS current DESCRIPTION "Lamp1 usage.(Hour)" ::= { vLampUsage3 1 } vLamp2Usage OBJECT-TYPE SYNTAX INTEGER(0..99999) UNITS "H" MAX-ACCESS read-only STATUS current DESCRIPTION "Lamp2 usage.(Hour)" ::= { vLampUsage3 2 } vLampWarning OBJECT-TYPE SYNTAX INTEGER(0..99999) UNITS "H" MAX-ACCESS read-only STATUS current DESCRIPTION "Lamp warning time.(Hour)" ::= { vLampUsage3 3 } vLamp1Remain OBJECT-TYPE SYNTAX INTEGER(0..999) UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "Lamp1 remainig time.(percent)" ::= { vLampUsage3 4 } vLamp2Remain OBJECT-TYPE SYNTAX INTEGER(0..999) UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "Lamp2 remainig time.(percent)" ::= { vLampUsage3 5 } vLamp1Strike OBJECT-TYPE SYNTAX INTEGER(0..99999) UNITS "Times" MAX-ACCESS read-only STATUS current DESCRIPTION "Lamp1 strike count.(Times)" ::= { vLampUsage3 6 } vLamp2Strike OBJECT-TYPE SYNTAX INTEGER(0..99999) UNITS "Times" MAX-ACCESS read-only STATUS current DESCRIPTION "Lamp2 strike count.(Times)" ::= { vLampUsage3 7 } vLampMode2 OBJECT-TYPE SYNTAX INTEGER { dual(1), lamp1(2), lamp2(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current lamp mode." ::= { vLamp 10 } -- -- * vInput ********************************************** -- vInputTerminal OBJECT-TYPE SYNTAX INTEGER { computer1(1), computer2(2), video1(3), video2(4), svideo1(5), svideo2(6), rgb1-video(7), rgb1-svideo(8), component(9), dvi-digital(10), dvi-analog(11), viewer(12), lan(13), testpattern(14), slot1-1(15), slot1-2(16), slot2-1(17), slot2-2(18), unknown(19) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vInput 1 } vInputSignal OBJECT IDENTIFIER ::= { vInput 2 } vEntryList OBJECT-TYPE SYNTAX INTEGER { default(1), user(2) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vInputSignal 1 } vSignalNo OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vInputSignal 2 } vSignalName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vInputSignal 3 } vSignalFormat OBJECT-TYPE SYNTAX INTEGER { rgb(1), component(2), video(3), s-video(4), scart(5), hdtv(6), digital(7), viewer(8), sdi(9) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vInputSignal 4 } vSignalFreqH OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vInputSignal 5 } vSignalFreqV OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vInputSignal 6 } vViewerSlide OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vInputSignal 7 } vViewerTotal OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vInputSignal 8 } vActiveTitle OBJECT IDENTIFIER ::= { vInput 3 } vActiveTitleNumber OBJECT-TYPE SYNTAX INTEGER(0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Selected title. If this value is 0, it means not to select any titles." ::= { vActiveTitle 1 } vActiveTitleName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name of Selected title. If any titles are not selected, returns NULL." ::= { vActiveTitle 2 } vActivePort OBJECT-TYPE SYNTAX INTEGER { portAuto(1), port292-A(2), port292-B(3), port292-Dual-AB(4), portReserved1(5), portTestPattern(6), portDVI-A(7), portDVI-B(8), portDVI-Dual-Twin(9), portReserved2(10), portReserved3(11), portDVI-Dual-Twin-MMS(12), port292-C(13), port292-D(14), port292-Dual-CD(15), port292-Quad(16), portIMB(17), portUnknown(18) } MAX-ACCESS read-only STATUS current DESCRIPTION "Active Data Port of the cinema projector." ::= { vActiveTitle 3 } vActiveSourceType OBJECT-TYPE SYNTAX INTEGER(-1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "If active port is 292-A or B or C or D port 0x00 4:2:2 Unpacked, 10bits/Color (default) 0x01 4:2:2 Packed, 12bits/Color 0x02 4:4:4 Packed, 10bits/Color 0x03 4:4:4 Packed, 12bits/Color If active port is 292-Dual(AB or CD), 0x00 4:2:2 Packed, 10 bits, O/E Pixels (default) 0x01 4:2:2 Packed, 10 bits, O/E Lines 0x02 4:2:2 Packed, 12 bits, O/E Pixels 0x03 4:2:2 Packed, 12 bits, O/E Lines 0x04 4:4:4 Unpacked, 10 bits 0x05 4:4:4 Packed, 10 bits, Mixed 0x06 4:4:4 Packed, 10 bits, O/E Pixels 0x07 4:4:4 Packed, 12 bits 0x08 4:2:2 Unpacked, 10 bits, O/E, Frame 0x09 4:2:2 Unpacked, 10 bits 0x0A 4:2:2 Packed, 12 bits If active port is 292-Quad, 0x01 4:2:2 Packed, 12 bits, O/E, Frame (default) 0x02 4:4:4 Unpacked, 10 bits, O/E, Frame 0x03 4:4:4 Packed, 12 bits, O/E, Frame If active port is DVI-A or DVI-B, 0x00 8 bits/color, Unpacked (default) 0x01 10 bits/color, Packed 0x02 12 bits/color, Packed 0x03 8 bits/color, Unpacked, 3D If active port is DVI-Dual/Twin, 0x03 Twin: 8 bits/color, Unpacked (default) 0x04 Twin: 10 bits/color, Unpacked 0x05 Twin: 12 bits/color, Packed 0x06 Twin: 8 bits/color, Unpacked, 3D If active port is IMB, 0x00 4:4:4 12bit (default) 0x01 4:2:2 12bit If fails to get this information, return -1." ::= { vActiveTitle 4 } vActivePCF OBJECT-TYPE SYNTAX DisplayString (SIZE(0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Active PCF file name." ::= { vActiveTitle 5 } vActiveSCREEN OBJECT-TYPE SYNTAX DisplayString (SIZE(0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Active SCREEN file name." ::= { vActiveTitle 6 } vAspectRatio OBJECT-TYPE SYNTAX INTEGER (-1..8000) UNITS "x0.001" MAX-ACCESS read-only STATUS current DESCRIPTION "Current aspect ratio. If fails to get this information, return -1." ::= { vActiveTitle 7 } vSubTitleStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), unknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current subtitle function setting." ::= { vActiveTitle 8 } vActiveDataType OBJECT-TYPE SYNTAX INTEGER (-1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "Current Data Type. 0x00 Progressive 0x01 Field Interlaced (Field Bit Normal) 0x02 Field Interlaced (Field Bit Inverted) 0x03 PsF (1st Field Dominant) 0x04 PsF (2nd Field Dominant) If fails to get this information, return -1." ::= { vActiveTitle 9 } vActive3D OBJECT-TYPE SYNTAX DisplayString (SIZE(0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Active 3D file name." ::= { vActiveTitle 10 } vTestPattern OBJECT IDENTIFIER ::= { vInput 4 } vTestPatternStatus OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Current testpattern setting." ::= { vTestPattern 1 } vTestPatternFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "Selected testpattern file name." ::= { vTestPattern 2 } -- -- * vOutput ********************************************** -- vVolume OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vOutput 1 } vFreeze OBJECT-TYPE SYNTAX INTEGER { freezeOff(1), freezeOn(2) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vOutput 2 } vMagnify OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vOutput 3 } vMute OBJECT IDENTIFIER ::= { vOutput 4 } vMutePicture OBJECT-TYPE SYNTAX INTEGER { muteOff(1), muteOn(2) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vMute 1 } vMuteSound OBJECT-TYPE SYNTAX INTEGER { muteOff(1), muteOn(2) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vMute 2 } vMuteOSD OBJECT-TYPE SYNTAX INTEGER { muteOff(1), muteOn(2) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vMute 3 } vPicture OBJECT IDENTIFIER ::= { vOutput 5 } vBrightness OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vPicture 1 } vContrast OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vPicture 2 } vColor OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vPicture 3 } vHue OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vPicture 4 } vSharpness OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vPicture 5 } vKeystoneH OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vPicture 6 } vKeystoneV OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vPicture 7 } -- -- * vSetting ********************************************** -- vLanguage OBJECT-TYPE SYNTAX INTEGER { lEnglish(1), lJapanese(2), lGerman(3), lFrench(4), lItalian(5), lSpanish(6), lSwedish(7), lChinese(8), lFinnish(9), lNorwegian(10), lDutch(11), lTurkish(12), lPolish(13), lRussian(14), lGreek(15), lKorean(16), lHungarian(17), lPortuguese(18), lOthers(19) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vSetting 1 } vOrientation OBJECT-TYPE SYNTAX INTEGER { desktop-front(1), ceiling-rear(2), desktop-rear(3), ceiling-front(4) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vSetting 2 } vBackground OBJECT-TYPE SYNTAX INTEGER { blue(1), black(2), logo(3) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "" ::= { vSetting 3 } -- -- * vTraps ********************************************** -- vTrapStatus NOTIFICATION-TYPE OBJECTS { vStatus, vSystemDouser, vActiveTitleNumber, vTestPatternStatus } STATUS current DESCRIPTION "This trap is sent, when the following status are changed. vStatus vSystemDouser vActiveTitleNumber vTestPatternStatus" ::= { vTraps 1 } vTrapProtect NOTIFICATION-TYPE OBJECTS { vSystemErrorCriticalCounts } STATUS current DESCRIPTION "This trap is sent, when the new critical error is occurred." ::= { vTraps 2 } vTrapProtectNC NOTIFICATION-TYPE OBJECTS { vSystemErrorNonCriticalCounts } STATUS current DESCRIPTION "This trap is sent, when the new error of Non-Critical is occurred." ::= { vTraps 3 } vTrapProtectStr NOTIFICATION-TYPE OBJECTS { vSystemErrorInformation } STATUS current DESCRIPTION "This trap is sent, when the new critical error is occurred." ::= { vTraps 4 } vTrapProtectStrNC NOTIFICATION-TYPE OBJECTS { vSystemErrorInformation } STATUS current DESCRIPTION "This trap is sent, when the new error of Non-Critical is occurred." ::= { vTraps 5 } END