first commit
This commit is contained in:
253
rpmbuild/BUILD/smarttms-1.0/apache-tomcat-7.0.63/BS_mibs/RFC1318-MIB
Executable file
253
rpmbuild/BUILD/smarttms-1.0/apache-tomcat-7.0.63/BS_mibs/RFC1318-MIB
Executable file
@@ -0,0 +1,253 @@
|
||||
-- Changes to RFC1318 (Parallel Printer MIB)
|
||||
-- No changes needed.
|
||||
-- dperkins@scruznet.com
|
||||
|
||||
|
||||
RFC1318-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
Counter
|
||||
FROM RFC1155-SMI
|
||||
transmission
|
||||
FROM RFC1213-MIB
|
||||
OBJECT-TYPE
|
||||
FROM RFC-1212;
|
||||
|
||||
-- this is the MIB module for Parallel-printer-like
|
||||
-- hardware devices
|
||||
|
||||
para OBJECT IDENTIFIER ::= { transmission 34 }
|
||||
|
||||
-- the generic Parallel-printer-like group
|
||||
|
||||
-- Implementation of this group is mandatory for all
|
||||
-- systems that have Parallel-printer-like hardware
|
||||
-- ports supporting higher level services such as
|
||||
-- character streams
|
||||
|
||||
paraNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The number of ports (regardless of their current
|
||||
state) in the Parallel-printer-like port table."
|
||||
::= { para 1 }
|
||||
|
||||
|
||||
-- the Parallel-printer-like Port table
|
||||
|
||||
paraPortTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF ParaPortEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A list of port entries. The number of entries is
|
||||
given by the value of paraNumber."
|
||||
::= { para 2 }
|
||||
|
||||
|
||||
paraPortEntry OBJECT-TYPE
|
||||
SYNTAX ParaPortEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Status and parameter values for a port."
|
||||
INDEX { paraPortIndex }
|
||||
::= { paraPortTable 1 }
|
||||
|
||||
ParaPortEntry ::=
|
||||
SEQUENCE {
|
||||
paraPortIndex
|
||||
INTEGER,
|
||||
paraPortType
|
||||
INTEGER,
|
||||
paraPortInSigNumber
|
||||
INTEGER,
|
||||
paraPortOutSigNumber
|
||||
INTEGER
|
||||
}
|
||||
|
||||
paraPortIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A unique value for each port. Its value ranges
|
||||
between 1 and the value of paraNumber. By
|
||||
convention and if possible, hardware port numbers
|
||||
map directly to external connectors. The value for
|
||||
each port must remain constant at least from one
|
||||
re-initialization of the network management agent to
|
||||
the next."
|
||||
::= { paraPortEntry 1 }
|
||||
|
||||
paraPortType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
other(1),
|
||||
centronics(2),
|
||||
dataproducts(3)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The port's hardware type."
|
||||
::= { paraPortEntry 2 }
|
||||
|
||||
paraPortInSigNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The number of input signals for the port in the
|
||||
input signal table (paraPortInSigTable). The table
|
||||
contains entries only for those signals the software
|
||||
can detect."
|
||||
::= { paraPortEntry 3 }
|
||||
|
||||
paraPortOutSigNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The number of output signals for the port in the
|
||||
output signal table (paraPortOutSigTable). The
|
||||
table contains entries only for those signals the
|
||||
software can assert."
|
||||
::= { paraPortEntry 4 }
|
||||
|
||||
|
||||
-- the Input Signal table
|
||||
|
||||
paraInSigTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF ParaInSigEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A list of port input control signal entries."
|
||||
::= { para 3 }
|
||||
|
||||
paraInSigEntry OBJECT-TYPE
|
||||
SYNTAX ParaInSigEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Input control signal status for a hardware port."
|
||||
INDEX { paraInSigPortIndex, paraInSigName }
|
||||
::= { paraInSigTable 1 }
|
||||
|
||||
ParaInSigEntry ::=
|
||||
SEQUENCE {
|
||||
paraInSigPortIndex
|
||||
INTEGER,
|
||||
paraInSigName
|
||||
INTEGER,
|
||||
paraInSigState
|
||||
INTEGER,
|
||||
paraInSigChanges
|
||||
Counter
|
||||
}
|
||||
|
||||
paraInSigPortIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The value of paraPortIndex for the port to which
|
||||
this entry belongs."
|
||||
::= { paraInSigEntry 1 }
|
||||
|
||||
paraInSigName OBJECT-TYPE
|
||||
SYNTAX INTEGER { power(1), online(2), busy(3),
|
||||
paperout(4), fault(5) }
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Identification of a hardware signal."
|
||||
::= { paraInSigEntry 2 }
|
||||
|
||||
paraInSigState OBJECT-TYPE
|
||||
SYNTAX INTEGER { none(1), on(2), off(3) }
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The current signal state."
|
||||
::= { paraInSigEntry 3 }
|
||||
|
||||
paraInSigChanges OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The number of times the signal has changed from
|
||||
'on' to 'off' or from 'off' to 'on'."
|
||||
::= { paraInSigEntry 4 }
|
||||
|
||||
|
||||
-- the Output Signal table
|
||||
|
||||
paraOutSigTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF ParaOutSigEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A list of port output control signal entries."
|
||||
::= { para 4 }
|
||||
|
||||
paraOutSigEntry OBJECT-TYPE
|
||||
SYNTAX ParaOutSigEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Output control signal status for a hardware port."
|
||||
INDEX { paraOutSigPortIndex, paraOutSigName }
|
||||
::= { paraOutSigTable 1 }
|
||||
|
||||
ParaOutSigEntry ::=
|
||||
SEQUENCE {
|
||||
paraOutSigPortIndex
|
||||
INTEGER,
|
||||
paraOutSigName
|
||||
INTEGER,
|
||||
paraOutSigState
|
||||
INTEGER,
|
||||
paraOutSigChanges
|
||||
Counter
|
||||
}
|
||||
|
||||
paraOutSigPortIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The value of paraPortIndex for the port to which
|
||||
this entry belongs."
|
||||
::= { paraOutSigEntry 1 }
|
||||
|
||||
paraOutSigName OBJECT-TYPE
|
||||
SYNTAX INTEGER { power(1), online(2), busy(3),
|
||||
paperout(4), fault(5) }
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Identification of a hardware signal."
|
||||
::= { paraOutSigEntry 2 }
|
||||
|
||||
paraOutSigState OBJECT-TYPE
|
||||
SYNTAX INTEGER { none(1), on(2), off(3) }
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The current signal state."
|
||||
::= { paraOutSigEntry 3 }
|
||||
|
||||
paraOutSigChanges OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The number of times the signal has changed from
|
||||
'on' to 'off' or from 'off' to 'on'."
|
||||
::= { paraOutSigEntry 4 }
|
||||
|
||||
END
|
||||