fix
This commit is contained in:
930
rpmbuild/SOURCES/smarttms/apache-tomcat-7.0.63/BS_mibs/GDC-DC-MIB.mib
Executable file
930
rpmbuild/SOURCES/smarttms/apache-tomcat-7.0.63/BS_mibs/GDC-DC-MIB.mib
Executable file
@@ -0,0 +1,930 @@
|
||||
GDC-DC-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
gdc, gdcObjectGroups, gdcNotifications
|
||||
FROM GDC-MIB
|
||||
OBJECT-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
MODULE-IDENTITY, OBJECT-TYPE,
|
||||
Integer32
|
||||
FROM SNMPv2-SMI
|
||||
TruthValue, DisplayString
|
||||
FROM SNMPv2-TC;
|
||||
|
||||
gdcDC MODULE-IDENTITY
|
||||
LAST-UPDATED "200811121600Z"
|
||||
ORGANIZATION
|
||||
"GDC Technology Ltd"
|
||||
CONTACT-INFO
|
||||
" GDC Support
|
||||
|
||||
Email: support@gdc-tech.com"
|
||||
DESCRIPTION
|
||||
"The MIB module for all information related to GDC D-cinema servers"
|
||||
::= { gdc 1 }
|
||||
|
||||
serverInfo OBJECT IDENTIFIER ::= { gdcDC 1 }
|
||||
systemProps OBJECT IDENTIFIER ::= { gdcDC 2 }
|
||||
disks OBJECT IDENTIFIER ::= { gdcDC 3 }
|
||||
ethInfo OBJECT IDENTIFIER ::= { gdcDC 4 }
|
||||
mounts OBJECT IDENTIFIER ::= { gdcDC 5 }
|
||||
raid OBJECT IDENTIFIER ::= { gdcDC 6 }
|
||||
sensors OBJECT IDENTIFIER ::= { gdcDC 7 }
|
||||
notifications OBJECT IDENTIFIER ::= { gdcDC 8 }
|
||||
pci OBJECT IDENTIFIER ::= { gdcDC 9 }
|
||||
|
||||
manufacturer OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The manufacturer of the server."
|
||||
::= { serverInfo 7 }
|
||||
|
||||
model OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The model number of the server."
|
||||
::= { serverInfo 1 }
|
||||
|
||||
serial OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The serial number of the server."
|
||||
::= { serverInfo 2 }
|
||||
|
||||
osVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The version of the installed OS image."
|
||||
::= { serverInfo 3 }
|
||||
|
||||
softwareVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The version of the playback software."
|
||||
::= { serverInfo 4 }
|
||||
|
||||
snmpAgentVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The version of the snmp agent."
|
||||
::= { serverInfo 5 }
|
||||
|
||||
sysUpTime OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The uptime of the server."
|
||||
::= { serverInfo 8 }
|
||||
|
||||
auditoriumNo OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Auditorium Number."
|
||||
::= { serverInfo 9 }
|
||||
|
||||
systemTime OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The system time of the server."
|
||||
::= { serverInfo 10 }
|
||||
|
||||
videoDevicesTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF VideoDevicesEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table listing the video output devices present in the server and their details."
|
||||
::= { serverInfo 6 }
|
||||
|
||||
videoDevicesEntry OBJECT-TYPE
|
||||
SYNTAX VideoDevicesEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the videoDevicesTable."
|
||||
INDEX { videoDeviceIndex }
|
||||
::= { videoDevicesTable 1 }
|
||||
|
||||
VideoDevicesEntry ::= SEQUENCE {
|
||||
videoDeviceIndex
|
||||
Integer32,
|
||||
videoDeviceName
|
||||
DisplayString,
|
||||
videoDriverVersion
|
||||
DisplayString,
|
||||
videoDeviceBoardTemp
|
||||
Integer32,
|
||||
videoDeviceFPGATemp
|
||||
Integer32
|
||||
}
|
||||
|
||||
videoDeviceIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The auxillary variable used for identifying instances of the columnar objects in the videoDevicesTable."
|
||||
::= { videoDevicesEntry 1 }
|
||||
|
||||
videoDeviceName OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The name of the video output device."
|
||||
::= { videoDevicesEntry 2 }
|
||||
|
||||
videoDriverVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The version of firmware/driver used by the video device."
|
||||
::= { videoDevicesEntry 3 }
|
||||
|
||||
videoDeviceBoardTemp OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The board temperature of the video device."
|
||||
::= { videoDevicesEntry 4 }
|
||||
|
||||
videoDeviceFPGATemp OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The FPGA temperature of the video device."
|
||||
::= { videoDevicesEntry 5 }
|
||||
|
||||
memTotal OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "KB"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The total amount of memory in the server (in KB)."
|
||||
::= { systemProps 1 }
|
||||
|
||||
memFree OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "KB"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The amount of free memory in the server (in KB)."
|
||||
::= { systemProps 2 }
|
||||
|
||||
processorTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF ProcessorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table listing the processors on the server and their details."
|
||||
::= { systemProps 3 }
|
||||
|
||||
processorEntry OBJECT-TYPE
|
||||
SYNTAX ProcessorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the processorTable."
|
||||
INDEX { processorIndex }
|
||||
::= { processorTable 1 }
|
||||
|
||||
ProcessorEntry ::= SEQUENCE {
|
||||
processorIndex
|
||||
Integer32,
|
||||
processorSpeed
|
||||
Integer32,
|
||||
processorType
|
||||
DisplayString
|
||||
}
|
||||
|
||||
processorIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The auxillary variable used for identifying instances of the columnar objects in the processorTable."
|
||||
::= { processorEntry 1 }
|
||||
|
||||
processorSpeed OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "MHz"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The speed of the processor (in MHz)."
|
||||
::= { processorEntry 2 }
|
||||
|
||||
processorType OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The type of the processor."
|
||||
::= { processorEntry 3 }
|
||||
|
||||
motherboardVendor OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The motherboard vendor."
|
||||
::= { systemProps 4 }
|
||||
|
||||
motherboardProduct OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The motherboard product."
|
||||
::= { systemProps 5 }
|
||||
|
||||
biosVendor OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The BIOS vendor."
|
||||
::= { systemProps 6 }
|
||||
|
||||
biosVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The BIOS version."
|
||||
::= { systemProps 7 }
|
||||
|
||||
biosReleaseDate OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The BIOS release date."
|
||||
::= { systemProps 8 }
|
||||
|
||||
diskTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF DiskEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table listing the hard disks used in the server."
|
||||
::= { disks 1 }
|
||||
|
||||
diskEntry OBJECT-TYPE
|
||||
SYNTAX DiskEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the diskTable."
|
||||
INDEX { diskIndex }
|
||||
::= { diskTable 1 }
|
||||
|
||||
DiskEntry ::= SEQUENCE {
|
||||
diskIndex
|
||||
Integer32,
|
||||
diskDevice
|
||||
DisplayString,
|
||||
diskCapacity
|
||||
Integer32,
|
||||
diskModel
|
||||
DisplayString,
|
||||
diskSerial
|
||||
DisplayString,
|
||||
diskSmartErrors
|
||||
TruthValue,
|
||||
diskTemperature
|
||||
Integer32
|
||||
|
||||
}
|
||||
|
||||
diskIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The auxillary variable used for identifying instances of the columnar objects in the diskTable."
|
||||
::= { diskEntry 1 }
|
||||
|
||||
diskDevice OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The system name for the hard disk."
|
||||
::= { diskEntry 2 }
|
||||
|
||||
diskCapacity OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "KB"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The capacity of the hard disk drive (in KB)."
|
||||
::= { diskEntry 3 }
|
||||
|
||||
diskModel OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The model name of the hard disk drive."
|
||||
::= { diskEntry 4 }
|
||||
|
||||
diskSmartErrors OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates whether the hard disk has any errors recorded by S.M.A.R.T."
|
||||
::= { diskEntry 5 }
|
||||
|
||||
diskSerial OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Serial no. of the hard disk drive."
|
||||
::= { diskEntry 6 }
|
||||
|
||||
diskTemperature OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Temperature of the hard disk drive."
|
||||
::= { diskEntry 7 }
|
||||
|
||||
ethInfoTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EthInfoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table listing the ethernet interfaces available on the server and their details."
|
||||
::= { ethInfo 1 }
|
||||
|
||||
ethInfoEntry OBJECT-TYPE
|
||||
SYNTAX EthInfoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the ethInfoTable."
|
||||
INDEX { ethIndex }
|
||||
::= { ethInfoTable 1 }
|
||||
|
||||
EthInfoEntry ::= SEQUENCE {
|
||||
ethIndex
|
||||
Integer32,
|
||||
ethMac
|
||||
DisplayString,
|
||||
ethAddress
|
||||
DisplayString,
|
||||
ethSpeed
|
||||
Integer32,
|
||||
ethUp
|
||||
TruthValue
|
||||
}
|
||||
|
||||
ethIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The auxillary variable used for identifying instances of the columnar objects in the ethInfoTable."
|
||||
::= { ethInfoEntry 1 }
|
||||
|
||||
ethMac OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The MAC address of the ethernet interface."
|
||||
::= { ethInfoEntry 2 }
|
||||
|
||||
ethAddress OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The IP address assigned to the ethernet interface."
|
||||
::= { ethInfoEntry 3 }
|
||||
|
||||
ethSpeed OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "Mbps"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The speed of the ethernet connection (in Mbps)."
|
||||
::= { ethInfoEntry 4 }
|
||||
|
||||
ethUp OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates whether the ethernet interface is connected to a network or not."
|
||||
::= { ethInfoEntry 5 }
|
||||
|
||||
mountTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF MountEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table listing the mounted filesystems on the server."
|
||||
::= { mounts 1 }
|
||||
|
||||
mountEntry OBJECT-TYPE
|
||||
SYNTAX MountEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the mountTable."
|
||||
INDEX { mountIndex }
|
||||
::= { mountTable 1 }
|
||||
|
||||
MountEntry ::= SEQUENCE {
|
||||
mountIndex
|
||||
Integer32,
|
||||
mountLocation
|
||||
DisplayString,
|
||||
mountTotalSpace
|
||||
Integer32,
|
||||
mountFreeSpace
|
||||
Integer32,
|
||||
mountUsePercent
|
||||
Integer32,
|
||||
mountAccess
|
||||
DisplayString
|
||||
}
|
||||
|
||||
mountIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The auxillary variable used for identifying instances of the columnar objects in the mountTable."
|
||||
::= { mountEntry 1 }
|
||||
|
||||
mountLocation OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The local directory on the server where the filesystem is mounted."
|
||||
::= { mountEntry 2 }
|
||||
|
||||
mountTotalSpace OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "KB"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The total capacity of the mounted filesystem (in KB)."
|
||||
::= { mountEntry 3 }
|
||||
|
||||
mountFreeSpace OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "KB"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The amount of available space on the mounted filesystem (in KB)."
|
||||
::= { mountEntry 4 }
|
||||
|
||||
mountUsePercent OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "%"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Used percentage space on the mounted filesystem (in %)."
|
||||
::= { mountEntry 5 }
|
||||
|
||||
mountAccess OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The access Permission of the filesystem mounted."
|
||||
::= { mountEntry 6 }
|
||||
|
||||
raidTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RaidEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table listing the raid filesystems on the server and their details."
|
||||
::= { raid 1 }
|
||||
|
||||
raidEntry OBJECT-TYPE
|
||||
SYNTAX RaidEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the raidTable."
|
||||
INDEX { raidIndex }
|
||||
::= { raidTable 1 }
|
||||
|
||||
RaidEntry ::= SEQUENCE {
|
||||
raidIndex
|
||||
Integer32,
|
||||
raidDevice
|
||||
DisplayString,
|
||||
raidUUID
|
||||
DisplayString,
|
||||
raidType
|
||||
Integer32,
|
||||
raidCapacity
|
||||
Integer32,
|
||||
raidDegraded
|
||||
TruthValue
|
||||
}
|
||||
|
||||
raidIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The auxillary variable used for identifying instances of the columnar objects in the raidTable."
|
||||
::= { raidEntry 1 }
|
||||
|
||||
raidDevice OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The system name for the raid device."
|
||||
::= { raidEntry 2 }
|
||||
|
||||
raidUUID OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The unique identifier for the raid device."
|
||||
::= { raidEntry 3 }
|
||||
|
||||
raidType OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The raid level of the raid device."
|
||||
::= { raidEntry 4 }
|
||||
|
||||
raidCapacity OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "KB"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The total capacity of the raid device (in KB)."
|
||||
::= { raidEntry 5 }
|
||||
|
||||
raidDegraded OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates whether the raid is in a degraded state or not."
|
||||
::= { raidEntry 6 }
|
||||
|
||||
cpuFanSpeed OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
UNITS "RPM"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { sensors 1 }
|
||||
|
||||
cpuTemperature OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
UNITS "degrees C"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { sensors 2 }
|
||||
|
||||
sysTemperature1 OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
UNITS "degrees C"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { sensors 3 }
|
||||
|
||||
sysTemperature2 OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
UNITS "degrees C"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { sensors 4 }
|
||||
|
||||
sysTemperature3 OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
UNITS "degrees C"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { sensors 5 }
|
||||
|
||||
videoDeviceNotFound NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate that the video device is missing"
|
||||
::= { notifications 1 }
|
||||
|
||||
videoDriverNotLoaded NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription, eventReference }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate that the video driver was not loaded"
|
||||
::= { notifications 2 }
|
||||
|
||||
serverTemperatureHigh NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription, eventReference }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate that the server temperature has gove above the specified limit"
|
||||
::= { notifications 3 }
|
||||
|
||||
fanSpeedLow NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription, eventReference }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate that the CPU fan speed has gone below the specified limit"
|
||||
::= { notifications 4 }
|
||||
|
||||
diskNotFound NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notificataion to indicate that a disk has not been detected"
|
||||
::= { notifications 5 }
|
||||
|
||||
mountNotFound NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate that a mount location has not been found"
|
||||
::= { notifications 6 }
|
||||
|
||||
raidNotFound NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate that a raid device was not found"
|
||||
::= { notifications 7 }
|
||||
|
||||
pciDeviceNotFound NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate that a PCI device was not found"
|
||||
::= { notifications 8 }
|
||||
|
||||
raidStatusDegraded NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription, eventReference }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate that the RAID device is degraded"
|
||||
::= { notifications 9 }
|
||||
|
||||
diskErrorDetected NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription, eventReference }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate that the disk device has S.M.A.R.T errors"
|
||||
::= { notifications 10 }
|
||||
|
||||
diskSpaceErrorDetected NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription, eventReference }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate that the disk space has reached threshold"
|
||||
::= { notifications 11 }
|
||||
|
||||
diskTemperatureHigh NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription, eventReference }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate that the disk temperature has gove above the specified limit"
|
||||
::= { notifications 12 }
|
||||
|
||||
ingestionStarted NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription, eventReference }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate that server started Ingestion"
|
||||
::= { notifications 13 }
|
||||
|
||||
ingestionCompleted NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription, eventReference }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate that server completed Ingestion"
|
||||
::= { notifications 14 }
|
||||
|
||||
ingestionFailed NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription, eventReference }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate that Ingestion has failed"
|
||||
::= { notifications 15 }
|
||||
|
||||
droppedFrame NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription, eventReference }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate Dropped Frame"
|
||||
::= { notifications 16 }
|
||||
|
||||
systemUpDays NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription, eventReference }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate that system is up for more than defined nunber of days"
|
||||
::= { notifications 17 }
|
||||
|
||||
snmpAgentStarted NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription, eventReference }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate SNMP Agent is started"
|
||||
::= { notifications 18 }
|
||||
|
||||
kdmMissing NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription, eventReference }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate KDM is missing"
|
||||
::= { notifications 19 }
|
||||
|
||||
snmpAgentStopped NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription, eventReference }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate SNMP Agent is stopped"
|
||||
::= { notifications 20 }
|
||||
|
||||
fireAlarm NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription, eventReference }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate Fire Alarm has reached threshold"
|
||||
::= { notifications 21 }
|
||||
|
||||
ethernetDown NOTIFICATION-TYPE
|
||||
OBJECTS { eventType, eventDescription, eventReference }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification to indicate network is down"
|
||||
::= { notifications 22 }
|
||||
|
||||
pciTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF PCIEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table listing the PCI devices on the server and their details."
|
||||
::= { pci 1 }
|
||||
|
||||
pciEntry OBJECT-TYPE
|
||||
SYNTAX PCIEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the pciTable."
|
||||
INDEX { pciIndex }
|
||||
::= { pciTable 1 }
|
||||
|
||||
PCIEntry ::= SEQUENCE {
|
||||
pciIndex
|
||||
Integer32,
|
||||
pciBusID
|
||||
DisplayString,
|
||||
pciDescription
|
||||
DisplayString
|
||||
}
|
||||
|
||||
pciIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The auxillary variable used for identifying instances of the columnar objects in the pciTable."
|
||||
::= { pciEntry 1 }
|
||||
|
||||
pciBusID OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The PCI bus ID for the PCI device."
|
||||
::= { pciEntry 2 }
|
||||
|
||||
pciDescription OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The PCI description for the PCI device."
|
||||
::= { pciEntry 3 }
|
||||
|
||||
gdcDCObjectGroups OBJECT IDENTIFIER ::= { gdcObjectGroups 1 }
|
||||
|
||||
serverInfoGroup OBJECT-GROUP
|
||||
OBJECTS { manufacturer, model, serial, osVersion, softwareVersion, snmpAgentVersion, videoDeviceName, videoDriverVersion, videoDeviceBoardTemp, videoDeviceFPGATemp, sysUpTime, auditoriumNo, systemTime }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of objects that provide server information"
|
||||
::= { gdcDCObjectGroups 1 }
|
||||
|
||||
systemPropsGroup OBJECT-GROUP
|
||||
OBJECTS { memTotal, memFree, processorSpeed, processorType, motherboardVendor, motherboardProduct, biosVendor, biosVersion, biosReleaseDate }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of objects that provide system information"
|
||||
::= { gdcDCObjectGroups 2 }
|
||||
|
||||
disksGroup OBJECT-GROUP
|
||||
OBJECTS { diskDevice, diskCapacity, diskModel, diskSerial, diskSmartErrors, diskTemperature }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of objects that provide disk related information"
|
||||
::= { gdcDCObjectGroups 3 }
|
||||
|
||||
ethGroup OBJECT-GROUP
|
||||
OBJECTS { ethMac, ethAddress, ethSpeed, ethUp }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of objects that provide ethernet related information"
|
||||
::= { gdcDCObjectGroups 4 }
|
||||
|
||||
mountsGroup OBJECT-GROUP
|
||||
OBJECTS { mountLocation, mountTotalSpace, mountFreeSpace, mountUsePercent, mountAccess }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of objects that provide information related to mounted filesystems"
|
||||
::= { gdcDCObjectGroups 5 }
|
||||
|
||||
raidGroup OBJECT-GROUP
|
||||
OBJECTS { raidDevice, raidUUID, raidType, raidCapacity, raidDegraded }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of objects that provide information related to mounted filesystems"
|
||||
::= { gdcDCObjectGroups 6 }
|
||||
|
||||
sensorsGroup OBJECT-GROUP
|
||||
OBJECTS { cpuFanSpeed, cpuTemperature, sysTemperature1, sysTemperature2, sysTemperature3 }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of objects that provide information collected from the motherboard sensors"
|
||||
::= { gdcDCObjectGroups 7 }
|
||||
|
||||
pciGroup OBJECT-GROUP
|
||||
OBJECTS { pciBusID, pciDescription }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of objects that provide information related to PCI devices"
|
||||
::= { gdcDCObjectGroups 9 }
|
||||
|
||||
dcNotificationsGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS { videoDeviceNotFound, videoDriverNotLoaded, serverTemperatureHigh, fanSpeedLow, diskNotFound, mountNotFound, raidNotFound, pciDeviceNotFound, raidStatusDegraded, diskErrorDetected, diskSpaceErrorDetected, diskTemperatureHigh, ingestionStarted, ingestionCompleted, ingestionFailed, droppedFrame, systemUpDays, snmpAgentStarted, kdmMissing, snmpAgentStopped, fireAlarm, ethernetDown }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of notifications that provide warnings about the server's state"
|
||||
::= { gdcNotifications 3 }
|
||||
|
||||
END
|
||||
|
||||
|
||||
Reference in New Issue